Aslam
Aslam has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
A. J. Waker
1 shared publicationA.J. Waker
AECL, Chalk River Laboratories, Chalk River, Ont., Canada K0J 1J0
1 shared publicationF. E. McNeill
1 shared publicationF.E McNeill
1 shared publicationF.E. McNeill
Medical Physics and Applied Radiation Sciences Unit, McMaster University, Nuclear Research Building, Hamilton, Ont., Canada L8S 4K1
1 shared publicationW. V. Prestwich
1 shared publication
Latest Publications
- 1 June 2003
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 58 (6) , 629-642
Development of a low-energy monoenergetic neutron source for applications in low-dose radiobiological and radiochemical research
- 1 June 2003
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 58 (6) , 629-642
Development of a low-energy monoenergetic neutron source for applications in low-dose radiobiological and radiochemical research
- 1 March 2003
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 58 (3) , 321-331
Lithium target performance evaluation for low-energy accelerator-based in vivo measurements using gamma spectroscopy
- 1 March 2003
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 58 (3) , 321-331
Lithium target performance evaluation for low-energy accelerator-based in vivo measurements using gamma spectroscopy
- 1 March 2003
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 103 (4) , 311-322
Investigating the TEPC radiation quality factor response for low energy accelerator based clinical applications
The use of a tissue equivalent proportional counter (TEPC) filled with propane based tissue equivalent gas simulating a 2 µm diameter tissue sphere has been investigated to estimate the radiation quality factor of the neutron fields used in in vivo neutron activation measurements at the McMaster University 3 MV Van de Graaff accelerator. The counter response to estimate the effective quality factor based on the definitions of Q(L) provided in ICRP 26 and 60 as a function of neutron energy has been examined experimentally using monoenergetic and continuous neutron spectra in the energy range of 35 to 600 keV. In agreement with other studies, the counter failed to provide a flat RQ response and showed a sharp drop below 200 keV neutron energy. Development of an algorithm to evaluate the quality factors using measured dose-mean lineal energy, yD, and comparison of the algorithm with other reported algorithms and analytical methods developed for the improvement in TEPC dose equivalent response has been reported.
- 1 March 2003
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 103 (4) , 311-322
Investigating the TEPC radiation quality factor response for low energy accelerator based clinical applications
The use of a tissue equivalent proportional counter (TEPC) filled with propane based tissue equivalent gas simulating a 2 µm diameter tissue sphere has been investigated to estimate the radiation quality factor of the neutron fields used in in vivo neutron activation measurements at the McMaster University 3 MV Van de Graaff accelerator. The counter response to estimate the effective quality factor based on the definitions of Q(L) provided in ICRP 26 and 60 as a function of neutron energy has been examined experimentally using monoenergetic and continuous neutron spectra in the energy range of 35 to 600 keV. In agreement with other studies, the counter failed to provide a flat RQ response and showed a sharp drop below 200 keV neutron energy. Development of an algorithm to evaluate the quality factors using measured dose-mean lineal energy, yD, and comparison of the algorithm with other reported algorithms and analytical methods developed for the improvement in TEPC dose equivalent response has been reported.