Antonis A. Armoundas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Antonis A. Armoundas has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
A. B. Feldman
Division of Health Sciences & Technology, Harvard University-Massachusetts Institute of Technology, Cambridge, USA
1 shared publicationAndrew B. Feldman
Harvard University-Massachusetts Institute of Technology
1 shared publicationD. A. Sherman
Cornell College, Mount Vernon, USA
1 shared publicationR. J. Cohen
Division of Health Sciences & Technology, Harvard University-Massachusetts Institute of Technology, Cambridge, USA
1 shared publicationRamakrishna Mukkamala
Harvard University-Massachusetts Institute of Technology
1 shared publicationRichard J. Cohen
Harvard University-Massachusetts Institute of Technology
1 shared publication
Latest Publications
- 1 May 2003
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 31 (5) , 564-576
A Single Equivalent Moving Dipole Model: An Efficient Approach for Localizing Sites of Origin of Ventricular Electrical Activation
We propose a new method for guiding catheter ablation procedures to abolish sites of origin of arrhythmias. This method models both cardiac electrical activity and current pulses delivered from the...
- 1 May 2003
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 31 (5) , 564-576
A Single Equivalent Moving Dipole Model: An Efficient Approach for Localizing Sites of Origin of Ventricular Electrical Activation
We propose a new method for guiding catheter ablation procedures to abolish sites of origin of arrhythmias. This method models both cardiac electrical activity and current pulses delivered from the...
- 1 September 2001
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 39 (5) , 562-570
Applicability of the single equivalent point dipole model to represent a spatially distributed bio-electrical source
Although the single equivalent point dipole model has been used to represent well-localised bio-electrical sources, in realistic situations the source is distributed. Consequently, position estimates of point dipoles determined by inverse algorithms suffer from systematic error due to the non-exact applicability of the inverse model. In realistic situations, this systematic error cannot be avoided, a limitation that is independent of the complexity of the torso model used. This study quantitatively investigates the intrinsic limitations in the assignment of a location to the equivalent dipole due to distributed electrical source. To simulate arrhythmic activity in the heart, a model of a wave of depolarisation spreading from a focal source over the surface of a spherical shell is used. The activity is represented by a sequence of concentric belt sources (obtained by slicing the shell with a sequence of parallel plane pairs), with constant dipole moment per unit length (circumferentially) directed parallel to the propagation direction. The distributed source is represented by N dipoles at equal arc lengths along the belt. The sum of the dipole potentials is calculated at predefined electrode locations. The inverse problem involves finding a single equivalent point dipole that best reproduces the electrode potentials due to the distributed source. The inverse problem is implemented by minimising the χ2 per degree of freedom. It is found that the trajectory traced by the equivalent dipole is sensitive to the location of the spherical shell relative to the fixed electrodes. It is shown that this trajectory does not coincide with the sequence of geometrical centres of the consecutive belt sources. For distributed sources within a bounded spherical medium, displaced from the sphere's centre by 40% of the sphere's radius, it is found that the error in the equivalent dipole location varies from 3 to 20% for sources with size between 5 and 50% of the sphere's radius. Finally, a method is devised to obtain the size of the distributed source during the cardiac cycle.
- 1 September 2001
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 39 (5) , 562-570
Applicability of the single equivalent point dipole model to represent a spatially distributed bio-electrical source
Although the single equivalent point dipole model has been used to represent well-localised bio-electrical sources, in realistic situations the source is distributed. Consequently, position estimates of point dipoles determined by inverse algorithms suffer from systematic error due to the non-exact applicability of the inverse model. In realistic situations, this systematic error cannot be avoided, a limitation that is independent of the complexity of the torso model used. This study quantitatively investigates the intrinsic limitations in the assignment of a location to the equivalent dipole due to distributed electrical source. To simulate arrhythmic activity in the heart, a model of a wave of depolarisation spreading from a focal source over the surface of a spherical shell is used. The activity is represented by a sequence of concentric belt sources (obtained by slicing the shell with a sequence of parallel plane pairs), with constant dipole moment per unit length (circumferentially) directed parallel to the propagation direction. The distributed source is represented by N dipoles at equal arc lengths along the belt. The sum of the dipole potentials is calculated at predefined electrode locations. The inverse problem involves finding a single equivalent point dipole that best reproduces the electrode potentials due to the distributed source. The inverse problem is implemented by minimising the χ2 per degree of freedom. It is found that the trajectory traced by the equivalent dipole is sensitive to the location of the spherical shell relative to the fixed electrodes. It is shown that this trajectory does not coincide with the sequence of geometrical centres of the consecutive belt sources. For distributed sources within a bounded spherical medium, displaced from the sphere's centre by 40% of the sphere's radius, it is found that the error in the equivalent dipole location varies from 3 to 20% for sources with size between 5 and 50% of the sphere's radius. Finally, a method is devised to obtain the size of the distributed source during the cardiac cycle.