VPVassilios E Papalois

Vassilios E Papalois

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Vassilios E Papalois has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 30 January 2007
      • Vol. 91  (6) , 345-7

    Surgical management of multiple donor veins in renal transplantation.

    by C Gerstenkorn, V E Papalois, O Thomusch, Alexander P. Maxwell, N Hakim

    The surgical aspects of renal transplantation have been standardized for decades regarding normal anatomy of donor kidneys. In certain situations, as in multiple donor veins, there are still challenges regarding the technical management. In > 95%, there is only one renal vein, or the additional vein/veins are so small that they can be ligated without hesitation. In < 5%, there are two main draining veins, and they can be similar in diameter. The management of these cases varies. Some surgeons implant both veins separately, leave them on a common caval patch, or implant the smaller vein into the larger vein as an end-to-side anastomosis, allowing for one venous anastomosis in the recipient. We describe two cases of donor kidneys with two similar-sized veins and conclude that ligation of the smaller vein, even if its size is substantial (up to 1 cm), can be the safest option to avoid surgical complications.

    • 7 May 2003
      • Vol. 88  (1) , 52-4

    Successful reversal of steal syndrome following creation of arteriovenous fistula by banding with a ringed Gore-Tex cuff: a new technique.

    by Vassilios E Papalois, Konstantinos N Haritopoulos, Ken Farrington, Nadey S Hakim

    Steal syndrome, especially in elderly patients with peripheral vascular disease, is a serious complication following creation of an arteriovenous fistula (AVF) that, if neglected, can lead to amputation. The classic maneuver to deal with the steal syndrome is ligating the AVF and performing another procedure to gain dialysis access. We describe a simple technique of effectively reversing the steal syndrome by banding the vein of the AVF with a ringed Gore-Tex cuff that salvages the AVF and allows its immediate use for dialysis.

    • 12 June 2002
      • Vol. 86  (4) , 210-2

    Reversal of steal syndrome following creation of arteriovenous fistula by banding with a Gore-Tex cuff: a new technique.

    by V E Papalois, K N Haritopoulos, C Labruzzo, K Farrington, N S Hakim

    Steal syndrome, especially in elderly patients with peripheral vascular disease, is a serious complication following creation of an arteriovenous fistula (AVF) that, if neglected, can lead to amputation. The classic maneuver to deal with the steal syndrome is the ligation of the AVF and performance of another procedure to gain dialysis access. We describe a simple technique of effectively reversing the steal syndrome by banding the vein of the AVF with a ringed Gore-Tex cuff that salvages the AVF and allows its immediate use for dialysis.

    • 14 March 2002
      • Vol. 86  (1) , 39-41

    Successful partial transplant pancreatectomy with end-to-side duct-to-ureter anastomosis: salvage of a pancreatic allograft.

    by J Romagnoli, V E Papalois, K N Haritopoulos, N S Hakim

    Segmental pancreatic transplantation has been abandoned because of the high incidence of technical complications. We report the first case in the literature of the salvage of a partially ischemic pancreatic allograft. The procedure consisted of resecting the head of the pancreas and draining the residual segment to the ureter with a duct-to-ureter end-to-side anastomosis. The postoperative course was uneventful, and 15 months after surgery graft function is satisfactory with a urinary amylase level of 5000 U/h. The duct-to-ureter drainage technique should be part of every transplant surgeon's repertoire, because in emergency situations like the one described, it can be used to save a pancreatic allograft.

    • 10 February 2000
      • Vol. 84  (4) , 313-7

    Small bowel transplantation.

    by N S Hakim, V E Papalois

    Many patients die each year lacking only a functional small bowel to survive. The minimum amount of small intestinal absorptive surface required to sustain life varies from patient to patient. Prolonged survival with oral alimentation alone has been reported in a few patients with an intact duodenum and as little as 15-45 cm of residual jejunum. However, without long-term total parenteral nutrition (TPN), prolonged patient survival is the exception rather than the rule. Chronic parenteral nutrition is associated with complications, including sepsis, venous thrombosis, metabolic disorders and liver dysfunction. From studies of patients currently on long-term TPN, it would appear that there are between two and three patients per million of population per year who develop irreversible small bowel failure. It is estimated that 20 new patients/year in the UK receiving home TPN would be potential candidates for small bowel transplantation.


    • 26 October 1999
      • Vol. 84  (3) , 258-61

    Donor selection for xenotransplantation: detection of Galalpha1-3Gal on different porcine organs.

    by V E Papalois, L C Goldberg, J Lee, R C Preston, N S Hakim, T Cairns, D H Taube

    The expression of the major porcine xenoantigens (Galalpha1-3Gal) in different tissues varies between species. The selection of suitable donors and the interpretation of studies which attempt to prevent hyperacute rejection are dependent on donor expression of Galalpha1-3Gal. Screening of large number of animals to find potential Galalpha1-3Gal negative donors requires a robust, tissue-based and practical method of assessing Galalpha1-3Gal expression. In this study, we have assessed the expression of Galalpha1-3Gal in a variety of pig organs using anti Galalpha1-3Gal antibody. Biopsies of heart, kidney, ear and tail were obtained from 20 outbred pigs. Biopsies were fixed in formalin and stained with a human anti Galalpha1-3Gal antibody obtained from pooled human AB serum passed down a Galalpha1-3Gal immunoadsorbent column. Tissue from all 4 organs from all 20 pigs expressed Galalpha13Gal. This study shows that detection of Galalpha1-3Gal on an ear or tail biopsy is a simple but very reliable method for assessing Galalpha1-3Gal expression on the heart and kidney and facilitates donor selection for xenotransplantation.


    • 17 July 1999
      • Vol. 84  (2) , 183-4

    Use of the inferior epigastric artery as a jump graft for reconstruction of a lower pole artery for renal transplantation.

    by V E Papalois, N S Hakim

    Before a kidney can be transplanted, the reconstruction of a damaged lower pole artery is vital to preserve the blood supply of the ureter.


    • 30 March 1999
      • Vol. 83  (4) , 327-9

    Successful procurement of 50 pancreatic grafts using a simple and fast technique.

    by N S Hakim, V E Papalois

    The procurement of a pancreatic graft must be as meticulous as possible and with minimum handling and blood loss so that the transplant procedure can be carried out with no complications. We describe the technique we are using in our institution which, contrary to others, requires that most of the dissection for donor pancreatectomy be done after crossclamping and intravascular flushing of the abdominal organs. We have performed 50 consecutive procurements of pancreatic grafts using this technique. All grafts were successfully transplanted with no evidence of post-transplant primary non-function or graft pancreatitis. We believe that this technique is faster and minimises handling of the pancreas and blood loss resulting in excellent post-transplant metabolic function of the pancreatic graft.


    • 16 December 1998
      • Vol. 83  (2) , 177-80

    Use of vascular closure staples in vascular access for dialysis, kidney and pancreas transplantation.

    by V E Papalois, J Romagnoli, N S Hakim

    We report our experience with the use of the vascular closure staples (VCS) in vascular access for dialysis, as well as in kidney and pancreas transplantation. We used the VCS for 50 endogenous arterio-venous fistulas (AVFs). There were no complications. The use of the VCS contributed in creating an excellent anastomosis and minimising operative time. All AVFs are in use for dialysis (follow up two months to one year). The excellent results from our experience with the use of VCS for vascular access encouraged us to use them in kidney and pancreas transplantation. We performed six cadaveric kidney transplants (the first operation was the first application of the VCS in kidney transplantation in Europe) and two cadaveric pancreas-kidney transplants (the first operation being the first application of the VCS in pancreas transplantation in the world). There were no complications. The use of VCS created an excellent anastomosis and minimised warm ischaemia time. All kidney transplant recipients have normal creatinines (follow up 1-5 months) and the recipients of pancreatic transplants are insulin independent (follow up 1-3 months).


    • 26 August 1998
      • Vol. 83  (1) , 36-7

    Transplantation of an annular pancreas with enteric drainage.

    by J Romagnoli, V E Papalois, N S Hakim

    Annular pancreas (AP) is an uncommon congenital anomaly which often does not become symptomatic until late life. We report a case of successful transplantation of an AP in a type I IDDM woman. The whole pancreas with a duodenal cuff was procured from a 41-year-old previously healthy female. The AP was identified at the time of procurement and did not appear to have caused any significant duodenal obstruction. The graft was transplanted on the external iliac vessels and the exocrine secretions were drained enterically. In order to avoid any possible injury to the ductal system, a side-to-side duodenojejunal anastomosis was fashioned using the first and the second portion of the duodenum, leaving about 2 cm of free duodenal margin proximal to the pancreatic ring. The postoperative course was uneventful and at 1 month graft function is unremarkable. Although challenging from a technical point of view, transplantation of an AP is a safe procedure which allows good results. Given the limited number of organ donors and the difficulty in HLA-matching, every AP should be considered suitable for transplantation.