HHHuarui He

Huarui He

*This is an algorithmically generated author record based on publicly available information.

Huarui He has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • James K. Tusa

    Roche Diagnostic Corporation, 235 Hembree Park Drive, Roswell, Georgia 30076, and Roche Diagnostic GmbH, 1 Hans-List-Platz, A-8020 Graz, Austria

    1 shared publication
  • Marc J. P. Leiner

    Roche Diagnostic Corporation, 235 Hembree Park Drive, Roswell, Georgia 30076, and Roche Diagnostic GmbH, 1 Hans-List-Platz, A-8020 Graz, Austria

    1 shared publication
  • Mark A. Mortellaro

    Roche Diagnostic Corporation, 235 Hembree Park Drive, Roswell, Georgia 30076, and Roche Diagnostic GmbH, 1 Hans-List-Platz, A-8020 Graz, Austria

    1 shared publication
  • Robert J. Fraatz

    Roche Diagnostic Corporation, 235 Hembree Park Drive, Roswell, Georgia 30076, and Roche Diagnostic GmbH, 1 Hans-List-Platz, A-8020 Graz, Austria

    1 shared publication
  • Susanne T. Young

    Roche Diagnostic Corporation, 235 Hembree Park Drive, Roswell, Georgia 30076, and Roche Diagnostic GmbH, 1 Hans-List-Platz, A-8020 Graz, Austria

    1 shared publication

Latest Publications

  • A Fluorescent Chemosensor for Sodium Based on Photoinduced Electron Transfer

    by Huarui He, Mark A. Mortellaro, Marc J. P. Leiner, Susanne T. Young, Robert J. Fraatz, James K. Tusa

    A new optical sensor suitable for practical measurement of sodium in serum and whole blood samples is described. The optical sensor is based on a novel PET (photoinduced eletron transfer) fluoroionophore immobilized in a hydrophilic polymer layer. The design concept of the fluoroionophore follows the receptor-spacer-fluorophore approach to sensor design using intramolecular PET-based signal transduction. Key to the development of this sensor is the identification of a nitrogen-containing, sodium-binding ionophore, coupled with a fluorophore having the correct spectral and electron-accepting properties. The slope of the sensor is ∼0.5%/mM in the typical clinically significant range of 120−160 mM. This sensor has been implemented into a disposable cartridge, used for a commercially available critical care analyzer (Roche OPTI CCA) with precision better than ±1 mM (1 SD). The sensor displays excellent stability against hydrolysis and oxidation, leading to slope changes <5% after 9 months wet storage at 30 °C. On the basis of this design concept, fluoroionophores for other cations such as potassium, calcium and magnesium can be prepared by substitution of the ionophore.