Johannes Sperzel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Johannes Sperzel has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
H.F. Pitschner
2 shared publicationsT Schwarz
2 shared publicationsT. Schwarz
Kerckhoff Klinik, Cardiology, Bad Nauheim, Germany
2 shared publicationsA König
1 shared publicationA. Garg
Guidant Corporation, CRM Research, St. Paul MN, United States of America
1 shared publicationA. Koenig
Guidant Europe, CRM Clinical Research, Diegem, Belgium
1 shared publication
Latest Publications
- Open Access
- 1 June 2005
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 7 (Supplement) , 156-157
515 Clinical performance of a new atrial automatic threshold testing algorithm
G. Boriani, C. Butter, M. Biffi, T. Schwarz, A. Garg, A. Koenig, R. Willems, J. Sperzel; 515 Clinical performance of a new atrial automatic threshold testing a
- 1 June 2005
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 7 (Supplement) , 156-157
Open Access515 Clinical performance of a new atrial automatic threshold testing algorithm
G. Boriani, C. Butter, M. Biffi, T. Schwarz, A. Garg, A. Koenig, R. Willems, J. Sperzel; 515 Clinical performance of a new atrial automatic threshold testing a
- Open Access
- 1 December 2003
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 4 (suppl_1) , S67
548 Contractile response and mitral regurgitation after withdrawl of biventricular pacing
R. R. Brandt, R. Reiner, J. Sperzel, H. F. Pitschner, C. W. Hamm; 548 Contractile response and mitral regurgitation after withdrawl of biventricular pacing, Eu
- 1 December 2003
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 4 (suppl_1) , S67
Open Access548 Contractile response and mitral regurgitation after withdrawl of biventricular pacing
R. R. Brandt, R. Reiner, J. Sperzel, H. F. Pitschner, C. W. Hamm; 548 Contractile response and mitral regurgitation after withdrawl of biventricular pacing, Eu
- Open Access
- 1 October 2003
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 4 (Supplement) , A12
7.6 Paroxysmal atrial fibrillation in patient with ddd-pacemaker indication: is af-burden reduction with a novel algorithm possible?
J. Sperzel, J. Bénézet, G. Siemon, Ch. Reiner, T. Schwarz, G. Görtler, M. Rosenfeld; 7.6 Paroxysmal atrial fibrillation in patient with ddd-pacemaker indicatio
- 1 October 2003
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 4 (Supplement) , A12
Open Access7.6 Paroxysmal atrial fibrillation in patient with ddd-pacemaker indication: is af-burden reduction with a novel algorithm possible?
J. Sperzel, J. Bénézet, G. Siemon, Ch. Reiner, T. Schwarz, G. Görtler, M. Rosenfeld; 7.6 Paroxysmal atrial fibrillation in patient with ddd-pacemaker indicatio
- 1 January 2003
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 5 (1) , 83-89
Automatic capture verification in ICD lead systems using intracardiac ventricular evoked response and reduced coupling capacitance
Intracardiac ventricular evoked-response (ER) signals detected by implanted cardioverter defibrillator (ICD) lead systems were investigated for automatic capture verification (AC). ER signals were evaluated with an external pacing system equipped with a reduced coupling capacitance (CC=2.2 microF) in the pacing output circuit during ventricular step-down threshold testing at 0.4 ms pulse duration. Real-time pacing markers, surface ECG and intracardiac electrograms pre- and post-filtering were digitally recorded. Twenty consecutive patients, age 61+/-12 years, with leads from two different manufacturers were tested - 10 were implanted with acute leads (AL) and 10 with chronic leads (CL). The analysis was based on the ER amplitude during capture and on the ER-to-afterpotential ratio (SAR), with SAR>2 as the criterion for successful capture detection. ER amplitudes (median and range) were 8.1 mV (2.1-19.5 mV) for AL and 8.3 mV (3.7-14.2 mV) for CL. SAR values (median and range) were 48.0 (2.5-682.6) for AL and 13.2 (6.3-35.9) for CL, indicating that AC could successfully be applied in all patients. Reducing the pacing CC allows adequate ER detection for automatic capture verification on non-selected ICD lead systems. The effect of high-voltage shock treatment on ER signal detection requires further investigation.
- 1 January 2003
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 5 (1) , 83-89
Automatic capture verification in ICD lead systems using intracardiac ventricular evoked response and reduced coupling capacitance
Intracardiac ventricular evoked-response (ER) signals detected by implanted cardioverter defibrillator (ICD) lead systems were investigated for automatic capture verification (AC). ER signals were evaluated with an external pacing system equipped with a reduced coupling capacitance (CC=2.2 microF) in the pacing output circuit during ventricular step-down threshold testing at 0.4 ms pulse duration. Real-time pacing markers, surface ECG and intracardiac electrograms pre- and post-filtering were digitally recorded. Twenty consecutive patients, age 61+/-12 years, with leads from two different manufacturers were tested - 10 were implanted with acute leads (AL) and 10 with chronic leads (CL). The analysis was based on the ER amplitude during capture and on the ER-to-afterpotential ratio (SAR), with SAR>2 as the criterion for successful capture detection. ER amplitudes (median and range) were 8.1 mV (2.1-19.5 mV) for AL and 8.3 mV (3.7-14.2 mV) for CL. SAR values (median and range) were 48.0 (2.5-682.6) for AL and 13.2 (6.3-35.9) for CL, indicating that AC could successfully be applied in all patients. Reducing the pacing CC allows adequate ER detection for automatic capture verification on non-selected ICD lead systems. The effect of high-voltage shock treatment on ER signal detection requires further investigation.
- 1 September 2001
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 24 (9) , 1377-1382
Reduction of Pacing Output Coupling Capacitance for Sensing the Evoked Response
SPERZEL, J., et al.: Reduction of Pacing Output Coupling Capacitance for Sensing the Evoked Response. Sensing of the intracardiac evoked response (ER) after a pacing stimulus has been used in implan...
- 1 September 2001
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 24 (9) , 1377-1382
Reduction of Pacing Output Coupling Capacitance for Sensing the Evoked Response
SPERZEL, J., et al.: Reduction of Pacing Output Coupling Capacitance for Sensing the Evoked Response. Sensing of the intracardiac evoked response (ER) after a pacing stimulus has been used in implan...
- Open Access
- 1 January 2001
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 2 (Supplement) , A31
Chronic biventricular stimulation of advanced heart failure: Experience with different lead systems
J Sperzel, T Schwarz, W Ehrlich, H Bahavar, J Neuzner, J Goetzke; Chronic biventricular stimulation of advanced heart failure: Experience with different lead s
- 1 January 2001
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 2 (Supplement) , A31
Open AccessChronic biventricular stimulation of advanced heart failure: Experience with different lead systems
J Sperzel, T Schwarz, W Ehrlich, H Bahavar, J Neuzner, J Goetzke; Chronic biventricular stimulation of advanced heart failure: Experience with different lead s