AMAnders Mølster

Anders Mølster

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Anders Mølster has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Long-term follow-up after primary repair of the anterior cruciate ligament: clinical and radiological evaluation 15–23 years postoperatively

    by T. Strand, A. Mølster, M. Hordvik, Y. Krukhaug

    Introduction We have previously reported results after 2–5 and 5–10 years follow-up of repair of acute anterior cruciate ligament (ACL) ruptures by suturing. Reports of results after more than 10 years are rare. Materials and methods A total of 140 patients were operated on in the period 1975–1983 (age range 13–71 years, median 28 years) by the modified Palmer technique. Only 2 meniscus resections and 4 meniscectomies were performed at the primary operation; while 28 menisci were sutured. At follow-up,12 patients were dead. Eighteen patients (13%) underwent repeat operations for secondary instability. Of the remaining 110 patients, 81 appeared for follow-up. Results Only 6 secondary meniscus resections were performed, all in the group of 18 patients operated on again for instability. No secondary meniscus surgery was performed on the 81 patients who appeared for follow-up. The median Lysholm score was 88, and 58 of the 81 patients (71%) classified their total knee function as good or excellent. By KT-1000 testing, 33 (41%) patients had less than 3 mm anterior instability, 29 (36%) had 3–5 mm instability, and 17 (21%) had more than 5 mm. With 18 patients from the total of 128 living patients re-operated for instability, we estimate the rate of total failure of stability as 27%. Radiological osteoarthritis grade C was present in 8 operated and 2 control knees, while only 1 operated knee revealed osteoarthritis grade D. Thirty-four operated and 20 control knees had grade B. Osteoarthritis was correlated to more advanced age at injury, while correlation to function could not be proven. Radiographs were obtained of 61 patients at follow-up. Conclusions Some 50% of patients had stable or slightly unstable knees, and 40% good or excellent function according to the Lysholm score. Re-operation for instability was more frequent in younger patients, while ostearthritis was more frequent in older patients. The rate of meniscus resection or extirpation was low. Open repair by suture is no longer recommended. Further research is indicated on the possible use of refixation of the ruptured ACL by arthroscopy.


    • 30 September 2002
      • Vol. 122  (23) , 2274-6

    [Removal of osteosynthetic implants].

    by Anders Mølster, Jon Behring, Nils Roar Gjerdet, Arne Ekeland

    Removals of fracture implants constitute a considerable share of orthopaedic operations and take up significant hospital resources. In the Norwegian basic fracture course, guidelines are given on indications for removal as well as minimum function time for implants. Indications for implant removal are, however, relative, and we wanted to study actual practice in this field in Norway. An inquiry was made to Norwegian hospitals in spring 2000 concerning their current practice for implant removal. Most hospitals follow the suggestions given but there is still great variation, especially in age limits for routine removal of all implants, which range from 15 to 70 years. Implant removal is desirable after fracture healing but it requires a surgical procedure with a certain morbidity and incidence of complications. Lack of strict criteria for removal may explain varying practice. We conclude that there should be a uniform practice for implant removal in Norwegian hospitals. More research is warranted on the possible systemic and local long-term effects of implants remaining in situ in order to give more evidence-based indications for implant removal.


  • Intramedullary nailing in humeral shaft fractures

    by A. Mølster, Nils R. Gjerdet, Rolf M. Strand, Randi M. Hole, Leiv M. Hove

    The aim of this in vitro study was to compare the mechanical behavior of fixation by the Russell-Taylor nail with the more recent Polarus nail. Fixation with an experimental nail made from polyacetal polymer was also included in the study. Thirty humeri were fractured and randomized to receive one of the three nail types. A four-point nondestructive bending test was performed, as well as torsional testing to failure. The torsional test was designed to record the amount of ‘play’ (uncontrolled rotation) in the bone/implant construct. The Polarus nail gave higher rigidity of the nail/bone construct than the two other types. The Russell-Taylor nailing exhibited a high degree of ‘play’ (uncontrolled rotation). The polyacetal nails allowed a large elastic deformation before failure.