CHC. J. Houtman

C. J. Houtman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


C. J. Houtman has a total of 3 co-authors. Here are the top co-authors by number of shared publications:

  • A. Heerschap

    Department of Radiodiagnostics, University Medical Centre, Nijmegen, The Netherlands

    2 shared publications
  • D. F. Stegeman

    Department of Clinical Neurophysiology, Institute of Neurology, University Medical Centre, Nijmegen, The Netherlands

    2 shared publications
  • M. J. Zwarts

    Department of Clinical Neurophysiology, Institute of Neurology, University Medical Centre, Nijmegen, The Netherlands

    2 shared publications

Latest Publications

  • An additional phase in PCr use during sustained isometric exercise at 30% MVC in the tibialis anterior muscle

    by C. J. Houtman, A. Heerschap, M. J. Zwarts, D. F. Stegeman

    The occurrence of an abrupt acceleration in phosphocreatine hydrolysis in the tibial anterior muscle during the last part of a sustained isometric exercise at 30% maximal voluntary contraction until fatigue is demonstrated in seven out of eight healthy subjects by applying in vivo 31P NMR spectroscopy at 1.5 T field strength. This additional third phase in PCr hydrolysis, is preceded by a common biphasic pattern (first fast then slow) in PCr use. The NMR spectra, as localized by a surface coil and improved by proton irradiation, were collected at a time resolution of 16 s. Mean rates of PCr hydrolysis during exercise were −0.44 ± 0.19% s−1, −0.07 ± 0.04% s−1, and −0.29 ± 0.10% s−1 for the three successive phases. The increased rate of PCr hydrolysis, and also the loss of fine force control evident in the force records are consistent with increased involvement of large, fast‐fatiguable units later in the contraction. Copyright © 2002 John Wiley & Sons, Ltd.


  • pH heterogeneity in tibial anterior muscle during isometric activity studied by31P-NMR spectroscopy

    by C. J. Houtman, A. Heerschap, M. J. Zwarts, D. F. Stegeman

    The occurrence of pH heterogeneity in human tibial anterior muscle during sustained isometric exercise is demonstrated by applying 31P-nuclear magnetic resonance (NMR) spectroscopy in a study of seven healthy subjects. Exercise was performed at 30 and 60% of maximal voluntary contraction (MVC) until fatigue. The NMR spectra, as localized by a surface coil and improved by proton irradiation, were obtained at a high time resolution (16 s). They revealed the simultaneous presence of two pH pools during most experiments. Maximum difference in the two pH levels during exercise was 0.40 ± 0.07 (30% MVC,n = 7) and 0.41 ± 0.03 (60% MVC,n = 3). Complementary two-dimensional 31P spectroscopic imaging experiments in one subject supported the supposition that the distinct pH pools reflect the metabolic status of the main muscle fiber types. The relative size of the Pipeak in the spectrum attributed to the type II fiber pool increases with decreasing pH levels. This phenomenon is discussed in the context of the size principle stating that the smaller (type I) motor units are recruited first.