William Gerin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
William Gerin has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Carl Pieper
Cornell University Medical College–The New York Hospital, New York, New York, USA
1 shared publicationDana H. Bovbjerg
1 shared publicationDenise A Derafael
Cornell University Medical College–The New York Hospital, New York, New York, USA
1 shared publicationGary D. James
1 shared publicationJames Deich
Cornell University Medical College–The New York Hospital, New York, New York, USA
1 shared publicationNicholas Christenfeld
Cornell University Medical College–The New York Hospital, New York, New York, USA
1 shared publication
Latest Publications
- 1 October 2001
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 6 (5) , 257-262
How should we measure blood pressure in the doctorʼs office?
Blood pressure is the most ubiquitous diagnostic recording made in the doctor's office, but the measurement is subject to a number of sources of bias, which may lead to over- or underestimation. The current study examined the systematic influence of the way in which the measurements were taken - by the physician, by a nurse, or with the patient sitting alone, using an automated device. Blood pressure was measured in 17 essential hypertensive and 10 white-coat hypertensive individuals. On separate clinic visits, measurements were taken by the attending physician, by a nurse and using an automated device (Arteriosonde 1216). A repeated-measures ANOVA revealed that, for systolic pressure, there was a significant effect of measurement modality on blood pressure. Physician systolic pressures were on average approximately 10 mmHg higher than those taken by a nurse, nurse pressures being approximately 7 mmHg higher than those recorded using Arteriosonde. The effect on diastolic pressure was similar but smaller, and no nurse-Arteriosonde difference was observed. We conclude that the routine clinical assessment of blood pressure would be more representative of daily ambulatory pressure if an automated device, without doctor or nurse present, were used.
- 1 October 2001
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 6 (5) , 257-262
How should we measure blood pressure in the doctorʼs office?
Blood pressure is the most ubiquitous diagnostic recording made in the doctor's office, but the measurement is subject to a number of sources of bias, which may lead to over- or underestimation. The current study examined the systematic influence of the way in which the measurements were taken - by the physician, by a nurse, or with the patient sitting alone, using an automated device. Blood pressure was measured in 17 essential hypertensive and 10 white-coat hypertensive individuals. On separate clinic visits, measurements were taken by the attending physician, by a nurse and using an automated device (Arteriosonde 1216). A repeated-measures ANOVA revealed that, for systolic pressure, there was a significant effect of measurement modality on blood pressure. Physician systolic pressures were on average approximately 10 mmHg higher than those taken by a nurse, nurse pressures being approximately 7 mmHg higher than those recorded using Arteriosonde. The effect on diastolic pressure was similar but smaller, and no nurse-Arteriosonde difference was observed. We conclude that the routine clinical assessment of blood pressure would be more representative of daily ambulatory pressure if an automated device, without doctor or nurse present, were used.
- Open Access
- 1 February 1998
- Published by Elsevier in Journal of Psychosomatic Research
- Vol. 44 (2) , 209-218
The generalizability of cardiovascular responses across settings
- 1 February 1998
- Published by Elsevier in Journal of Psychosomatic Research
- Vol. 44 (2) , 209-218
Open AccessThe generalizability of cardiovascular responses across settings