FBF. J. Bolton

F. J. Bolton

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


F. J. Bolton has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 1 June 2004
      • Vol. 7  (2) , 96-101

    Assessment of pasteurisation of milk and cream produced by on-farm dairies using a fluorimetric method for alkaline phosphatase activity.

    by G Allen, F J Bolton, D R A Wareing, J K Williamson, P A Wright

    The alkaline phosphatase test is used as an indicator of adequate pasteurisation of milk and cream. A proprietary fluorimetric technique (Fluorophos) is a sensitive and quantitative method for the determination of alkaline phosphatase (ALP) activity in milk products. Currently, adequate pasteurisation of milk products is regarded as confirmed in samples that contain a residual bovine ALP activity of < or =500 mU/litre. This is equivalent to the statutory acceptable level of 4ug phenol/ml required by the EC analytical method. The purpose of the present study was to assess the effectiveness of pasteurisation of milk and cream produced by on-farm dairies. In a longitudinal study over a four-year period, 4,999 samples of milk and cream were collected from 130 on-farm dairies and from two large commercial dairies in NW England for comparison. Bovine ALP activity of >500 mU/litre was deemed as a failure and was found in 3.5% of whole milk, 2.4% semiskimmed milk, 5.0% of skimmed milk, and 39% of cream samples from on-farm dairies. Bovine ALP activity of >100 and <500 mU/litre was found in 18.4% of whole milk, 9.3% of semi-skimmed milk, 13.2% skimmed milk and 44.5% of cream samples from on-farm dairies. Results with skimmed milk samples showed significantly lower bovine ALP activity than whole milk. All 409 milk and cream samples from two large commercial dairies passed the fluorimetric test at less than 500 mU/litre of bovine ALP, and 99% of these milk and cream samples had bovine ALP activity of less than 100 mU/litre. The presence of residual bovine phosphatase indicates a failure and may be due to either inadequate pasteurisation or post pasteurisation contamination with raw milk. Residual bovine phosphatase was demonstrated in 108/114 (94.7%) of milk samples with a bovine ALP activity greater than 500 mU/litre, i.e. true failures. Of more concern is that residual bovine phosphatase was found in 395/401 (98.5%) of samples that gave bovine ALP activity greater than 100 mU/litre but equal to or less than 500 mU/litre. Residual bovine phosphatase was demonstrated in 37/108 (30.2%) of cream samples with bovine ALP activity greater than 500 mU/litre. Presence of reactivated bovine phosphatase is not an indication of a failure but can mask the presence of residual bovine phosphatase. Reactivated bovine phosphatase was found in 74/106 (69.8%) of cream samples. Our results confirm that the more sensitive fluorimetric method is suitable for testing pasteurised whole milk and semiskimmed milk, but for statutory purposes the acceptable level of residual bovine phosphatase should be <100 mU/litre. Our findings have highlighted a potential problem when testing skimmed milk and cream samples from on-farm dairies. To ensure public safety we need more stringent standards for the ALP test and new methods that will accurately confirm that pasteurisation of these products has been achieved.

  • Detection of Campylobacter jejuni and Campylobacter coli in Foods by Enrichment Culture and Polymerase Chain Reaction Enzyme-Linked Immunosorbent Assay

    by F. J. Bolton, A. D. Sails, A. J. Fox, D. R. A. Wareing, D. L. A. Greenway

    A polymerase chain reaction (PCR) assay based on a solution hybridization format with colorimetric end-point detection (PCR ELISA) was investigated for the specific detection of Campylobacter jejun...


  • Open Access

    Detection of Campylobacter jejuni and Campylobacter coli in Environmental Waters by PCR Enzyme-Linked Immunosorbent Assay

    by A. D. Sails, F. J. Bolton, A. J. Fox, D. R. A. Wareing, D. L. A. Greenway

    A PCR enzyme-linked immunosorbent assay (ELISA) assay was applied to the detection of Campylobacter jejuni and Campylobacter coli in environmental water samples after enrichment culture. Bacterial cells were concentrated from 69 environmental water samples by using filtration, and the filtrates were cultured in Campylobacter blood-free broth. After enrichment culture, DNA was extracted from the samples by using a rapid-boiling method, and the DNA extracts were used as a template in a PCR ELISA assay. A total of 51 samples were positive by either PCR ELISA or culture; of these, 43 were found to be positive by PCR ELISA and 43 were found to be positive by culture. Overall, including positive and negative results, 59 samples were concordant in both methods. Several samples were positive in the PCR ELISA assay but were culture negative; therefore, this assay may be able to detect sublethally damaged or viable nonculturable forms of campylobacters. The method is rapid and sensitive, and it significantly reduces the time needed for the detection of these important pathogens by 2 to 3 days.