GDGijs W. K. van Dedem

Gijs W. K. van Dedem

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gijs W. K. van Dedem has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Considerations on contactless conductivity detection in capillary electrophoresis

    by Erik Baltussen, Rosanne M. Guijt, Gert van der Steen, Frederic Laugere, Sander Baltussen, Gijs W. K. van Dedem

    Nearly all analyses by capillary electrophoresis (CE) are performed using optical detection, utilizing either absorbance or (laser‐induced) fluorescence. Though adequate for many analytical problems, in a large number of cases, e.g., involving non‐UV‐absorbing compounds, these optical detection methods fall short. Indirect optical detection can then still provide an acceptable means of detection, however, with a strongly reduced sensitivity. During the past few years, contactless conductivity detection (CCD) has been presented as a valuable extension to optical detection techniques. It has been demonstrated that with CCD detection limits comparable, or even superior, to (indirect) optical detection can be obtained. Additionally, construction of the CCD around the CE capillary is straightforward and robust operation is easily obtained. Unfortunately, in the literature a large variety of designs and operating conditions for CCD were described. In this contribution, several important parameters of CCD are identified and their influence on, e.g., detectability and peak shape is described. An optimized setup based on a well‐defined detection cell with three detection electrodes is presented. Additionally, simple and commercially available read‐out electronics are described. The performance of the CCD‐CE system was demonstrated for the analysis of peptides. Detection limits at the νM level were obtained in combination with good peak shapes and an overall good performance and stability.


  • Novel approach for fritless capillary electrochromatography

    by Erik Baltussen, Gijs W. K. van Dedem

    At present, the main limitation for the further adoption of capillary electrochromatography (CEC) in the (routine) laboratory is caused by the lack of reproducible and stable columns. The main source of column instability is concentrated in the frits needed to retain the packed bed inside the CEC capillary. The sintering process used to prepare the frits can be rather problematic and irreproducible, particularly for small stationary phase particles and wide column diameters. Since the (surface) composition of the frits is different from the bulk stationary phase packing, different electroosmotic flow (EOF) velocities are generated. This effect is assumed to be primarily responsible for rapid column destruction. In this contribution, a novel approach for the preparation of fritless CEC capillaries is presented and evaluated. Using 5 νm Hypersil ODS particles, separation efficiencies in the range of 130 000–200 000 plates/m were obtained. In a 100 νm inner diameter packed column, electrical currents up to 50 νA could be tolerated without negative effects such as bubble formation. The prepared CEC columns were found to be stable and could easily be operated continuously for several days without column damage. An additional advantage of the proposed tapering approach is that application of pressure on the in- and outlet vial during separation was not required to prevent bubble formation.