MFMarc Faraggi

Marc Faraggi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marc Faraggi has a total of 84 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 1 October 2001
      • Vol. 42  (10) , 1451-6

    Clinical impact of combination of scatter, attenuation correction, and depth-dependent resolution recovery for (201)Tl studies.

    by F Harel, R Génin, D Daou, R Lebtahi, N Delahaye, B O Helal, D Le Guludec, M Faraggi

    A lack of specificity for myocardial perfusion imaging has been widely reported, mostly related to false-positive defects on the inferior wall. The application of depth-dependent resolution recovery (RR), attenuation correction (AC) using external source devices, and scatter correction has been proposed to resolve this pitfall. We studied the clinical benefit of depth-dependent RR, nonuniform AC using a scanning line source, and scatter correction (photon energy recovery [PER]) compared with filtered backprojection alone. Eighty-two patients were included: 40 healthy volunteers with a low likelihood of coronary artery disease (control group) and 42 patients with proven right or circumflex coronary artery disease but without involvement of the left anterior descending artery. Among these 82 patients, the images of 33 were also processed with PER. RR did not alter the performance of filtered backprojection alone. AC + RR greatly improved specificity and the rate of normal (201)Tl SPECT findings in the control population (from 56% to 95% and from 53% to 100%, respectively) but significantly decreased sensitivity (from 92% to 54%). AC + RR generated a false anteroapical defect in 21% of patients and reverse redistribution of the apex in 23%. AC + RR significantly decreased the extent of the stress defect (from 4.09 to 3.21 segments, P < 0.003) and increased the perfusion score of the stress defect (from 0.78 +/- 0.72 to 1.47 +/- 1.11, P < 0.00061). Moreover, AC + RR generated overcorrection on the inferior wall, leading to false estimation of viability for 11 of 15 patients with an old inferior myocardial scar without evidence of residual viability. PER decreased overcorrection on the inferior wall, but without improving sensitivity. PER did not significantly reduce the number of anteroapical false-positives or the number of apical reverse distribution cases. AC + RR improved the specificity and normalcy rate of (201)Tl SPECT myocardial perfusion imaging but generated overcorrection on the inferior wall, leading to low sensitivity and to false evaluation of myocardial viability in 73% of the patients with inferior infarction. AC + RR also generated anteroapical artifacts. The addition of scatter correction did not significantly reduce these drawbacks.


    • 1 July 2001
      • Vol. 42  (7) , 1043-9

    Electrocardiographically gated blood-pool SPECT and left ventricular function: comparative value of 3 methods for ejection fraction and volume estimation.

    by D Daou, F Harel, B O Helal, T Fourme, P Colin, R Lebtahi, D Mariano-Goulart, M Faraggi, M Slama, D Le Guludec

    The current major limitation to development of electrocardiographically (ECG) gated blood-pool SPECT (GBPS) for measurement of the left ventricular (LV) ejection fraction (LVEF) and volumes is the lack of availability of clinically validated automatic processing software. Recently, 2 processing software methods for quantification of the LV function have been described. Their LVEFs have been validated separately, but no validation of the LV volume measurement has been reported. We compared 3 processing methods for evaluation of the LVEF (n = 29) and volumes (n = 58) in 29 patients: automatic geometric method (GBPS(G)), semiautomatic activity method (GBPS(M)), and 35% maximal activity manual method (GBPS(35%)). The LVEF provided by the ECG gated equilibrium planar left anterior oblique view (planar(LAO)) and the LV volumes provided by LV digital angiography (Rx) were used as gold standards. Whereas the GBPS(G) and GBPS(M) methods present similar low percentage variabilities, the GBPS(35%) method provided the lowest percentage variabilities for the LVEF and volume measurements (P < 0.04 and P < 0.02, respectively). The LVEF and volume provided by the 3 methods were highly correlated with the gold standard methods (r > 0.98 and r > 0.83, respectively). The LVEFs provided by the GBPS(35%) and GBPS(M) methods are similar and higher than those of the GBPS(G) method and planar(LAO) method, respectively (P < 0.0001). For the LVEF, there is no correlation between the average and paired absolute difference for the 3 GBPS methods against the planar(LAO) method, and the limits of agreement are relatively large. LV volumes are lower when calculated with the GBPS(M), GBPS(G), and Rx methods (P < 0.0001). However, the GBPS(35%) and Rx methods provide LV volumes that are similar. There is no linear correlation between the average and the paired absolute difference of volumes calculated with the GBPS(G) and GBPS(35%) methods against Rx LV volumes. However, a moderate linear correlation was found with the GBPS(M) method (r = 0.6; P = 0.0001). The 95% limits of agreement between the Rx LV volumes and the 3 GBPS methods are relatively large. GBPS is a simple, highly reproducible, and accurate technique for the LVEF and volume measurement. The reported findings should be considered when comparing results of different methods (GBPS vs. planar(LAO) LVEF; GBPS vs. Rx volume) and results of different GBPS processing methods.


    • 1 February 2001
      • Vol. 94  (2) , 118-23

    [Evaluation of the ejection fraction tomoscintigraphy synchronised with an electrocardiogram].

    by A Manrique, M Faraggi, H Eltchaninoff, A Cribier, D Le Guludec, P Véra

    Electrocardiographic gated myocardial scintigraphy (gated SPECT) allows simultaneous evaluation of left ventricular perfusion and contractility. The aim of this study was to assess the impact of the type of tracer and temporal sampling on the measurement of the ejection fraction by gated SPECT. Eighty-six consecutive patients (59 men, 27 women, average age 62 +/- 11 years) with a history of myocardial infarction (anterior N = 50--inferior N = 36) were studied. All had measurement of the isotopic ejection fraction by equilibrium angioscintigraphy and by gated SPECT sampled at 8 (N = 45, 52%) or 16 images/cycle RR (N = 41, 48%). After filtered retroprojection, the ejection fraction was calculated by a validated method (QGS). A better correlation between gated SPECT and equilibrium angioscintigraphy was observed at 16 images/cycle (r = 0.90) compared with 8 (r = 0.80). The Bland-Altman curves showed improved accuracy of the measurement of the ejection fraction by gated SPECT with 16 compared with 8 images/cycles sampling (mean differences of 0.37 +/- 6.06% and 4.3 +/- 7.71%, respectively). Multivariable analysis showed that temporary sampling was the only parameter to significantly affect the difference between the two methods. There was no difference between the use of Thallium and that of 99mTc-sestamibi. Gated SPECT, therefore, provides an accurate measurement of the ejection fraction for routine clinical usage, providing the acquisition is made at 16 images/cycle.

    • 1 January 2001
      • Vol. 42  (1) , 21-6

    Somatostatin receptor scintigraphy and gallium scintigraphy in patients with sarcoidosis.

    by R Lebtahi, B Crestani, N Belmatoug, D Daou, R Genin, M C Dombret, E Palazzo, M Faraggi, M Aubier, D Le Guludec

    Somatostatin receptor scintigraphy (SRS) has been shown to reveal sarcoidosis sites. The aim of this study was to prospectively compare SRS and gallium scintigraphy in the evaluation of pulmonary and extrapulmonary involvement in patients with proven sarcoidosis. Eighteen patients with biopsy-proven sarcoidosis were included. Nine were or recently had been receiving steroid therapy at the time of the examination. Planar gallium scintigraphy (head, chest, abdomen, and pelvis) and thoracic SPECT were performed at 48-72 h after injection of a mean dose of 138 +/- 21 MBq 67Ga. Planar SRS and thoracic SPECT were performed at 4 and 24 h after injection of a mean dose of 148 +/- 17 MBq 111n-pentetreotide. Gallium scintigraphy found abnormalities in 16 of 18 patients (89%) and detected 64 of 99 clinically involved sites (65%). SRS found abnormalities in 18 of 18 patients and detected 82 of 99 clinically involved sites (83%). Of the 9 treated patients, gallium scintigraphy found abnormalities in 7 (78%), detecting 23 of 39 clinically involved sites (59%), whereas SRS found abnormalities in 9, detecting 32 of 39 clinically involved sites (82%). This study suggests that, compared with gallium scintigraphy, SRS appears to be accurate and contributes to a better evaluation of organ involvement in sarcoidosis patients, especially those treated with corticosteroids.


    • 1 November 2000
      • Vol. 93  (11) , 1309-32

    [Recommendations of the French Society of Cardiology concerning the practice of ischemia provocation tests in adult nuclear cardiology].

    by A Furber, P Berdagué, C Cadiou, N David, M Faraggi, N Fourquet, J Hélias, D Le Guludec, P Y Marie, E Ouhayoun, et al.

    • 1 April 2000
      • Vol. 41  (4) , 567-74

    Diagnosis of extensive coronary artery disease: intrinisic value of increased lung 201 T1 uptake with exercise SPECT.

    by D Daou, N Delahaye, R Lebtahi, D Vilain, C Peker, M Faraggi, D Le Guludec

    Exercise lung 201 TI uptake calculated with planar imaging has an important diagnostic and prognostic value in patients with coronary artery disease (CAD). However, its value with SPECT imaging raises methodological concerns and is controversial. We studied its value for the discrimination between extensive (E) and limited (L) angiographic CAD with exercise SPECT. Four methods of lung-to-heart ratio quantification were calculated in patients with a low likelihood (< 5%) of CAD (n = 62). Their dependent variables were defined, and corresponding correction equations were derived. Receiver operating characteristic (ROC) analysis was performed in a pilot group (L-CAD, n = 49; E-CAD, n = 126) to define the optimal method of calculation of the lung-to-heart ratio. Its best threshold providing the best sensitivity for a specificity of 90% was defined. After correction for dependent variables, the 4 methods were also compared by ROC analysis and the optimal corrected method was compared with the optimal uncorrected method using ROC analysis and the best threshold. The consistency of these results in the validation group (L-CAD, n = 41; E-CAD, n = 122) and of the results of visual analysis of lung 201TI uptake were then verified. On ROC analysis in the pilot group, the optimal method of calculation of the lung-to-heart ratio was the mean activity in a region of interest drawn at the base of the lungs to the mean activity over the heart (Lb/H). For the best threshold, Lb/H presented a sensitivity of 34%. Corrected Lb/H still remained the best method of calculation on ROC analysis compared with the other corrected methods. On ROC analysis, there was no difference between corrected and uncorrected Lb/H. For the best threshold, corrected Lb/H presented a similar sensitivity of 37% compared with uncorrected Lb/H. When applied to the validation group (L-CAD, n = 41; E-CAD, n = 122), the best-defined threshold in the pilot group for corrected Lb/H presented a diagnostic value similar to that in the pilot group (sensitivity, 41%; specificity, 90%), but uncorrected Lb/H presented a higher sensitivity (47%; P < 0.04) and a slightly lower specificity (80%). Results of lung 201TI uptake visual analysis were inconsistent between pilot and validation groups (42% versus 58% sensitivity, P = 0.012; 86% versus 66% specificity, P = 0.023). For evaluation of E-CAD versus L-CAD, quantification of the exercise lung-to-heart 201TI uptake ratio with SPECT is feasible, reproducible, more discriminate than simple visual analysis, and best calculated as Lb/H. It presents an intrinsic diagnostic value even after correction for other clinically valuable dependent variables.


    • 1 March 2000
      • Vol. 41  (3) , 393-9

    Relationship between resting 201Tl reverse redistribution, microvascular perfusion, and functional recovery in acute myocardial infarction.

    by M Faraggi, D Karila-Cohen, E Brochet, R Lebtahi, D Czitrom, L J Feldman, P Assayag, D Doumit, G Steg, D Le Guludec

    201TI reverse redistribution is a common finding early after reperfusion therapy for myocardial infarction. Its mechanism and clinical implications remain unclear. The aim of this study was to clarify the relationships between reverse redistribution, microvascular perfusion, and myocardial viability. Resting, 10-min-postinjection, and redistribution 201TI data obtained for 33 patients 8 and 42 d after the onset of acute myocardial infarction were compared with echocardiographic wall motion measured acutely and on day 42. Microvascular perfusion was assessed by myocardial contrast echocardiography performed 10 min after restoration of complete patency of the infarct artery. Marked significant reverse redistribution was found on day 8 (absolute change, 7.5%+/-7.9% of the 10-min-postinjection defect size; P<5x0.000001) and significantly decreased on day 42 (2.7%+/-6.8%; P = 0.004 between days 8 and 42). The 10-min-postinjection defect size best predicted the final infarct size on day 42 and was closely related to microvascular perfusion. Patients with adequate reperfusion had a smaller postinjection defect on day 8 (21.1%+/-14.6%) and a larger reverse redistribution (10.2%+/-6.1%) than did patients with no reflow (35.3%+/-13% and 3.2%+/-9.2%, respectively; P<0.04 for both). Reverse redistribution was marked early after myocardial infarction in patients with complete patency of the infarct artery and decreased in subsequent weeks. Reverse redistribution was associated with restoration of adequate microvascular reperfusion and with myocardial salvage and viability. The early postinjection scans on day 8 were the relevant images for assessing myocardial salvage and predicting wall motion recovery.


    • 1 October 1999
      • Vol. 40  (10) , 1602-8

    Detection of bone metastases in patients with endocrine gastroenteropancreatic tumors: bone scintigraphy compared with somatostatin receptor scintigraphy.

    by R Lebtahi, G Cadiot, N Delahaye, R Genin, D Daou, M C Peker, D Chosidow, M Faraggi, M Mignon, D Le Guludec

    Scintigraphy with somatostatin analogs is a sensitive method for the staging and therapeutic management of patients with endocrine gastroenteropancreatic (GEP) tumors. The aim of this study was to compare prospectively somatostatin receptor scintigraphy (SRS) using 111n-pentetreotide with bone scintigraphy using 99mTc-hydroxymethylene diphosphonate for the detection of bone metastases. One-hundred-forty-five patients with proven endocrine GEP tumors were investigated. Patients were classified according to the presence of bone metastases as indicated by CT, MRI or histologic data. Group I included 19 patients with confirmed bone metastases, and group II included 126 patients without bone metastases. In group I, SRS was positive in all 19 patients with bone metastases, and bone scintigraphy was positive in 17 patients. Bone metastases were found to occur predominantly in patients with liver metastases. In group 11, 5 patients had recent bone surgery for fracture or arthritis. SRS showed bone uptake in 4 of these patients, and bone scanning showed abnormal uptake in 5. In 7 of the remaining 121 group II patients, SRS was negative and bone scanning showed abnormal bone uptake suggesting bone metastases. The detection of bone metastases was of major prognostic value, because 42% of group 1 patients died during a 2-y follow-up. In patients with GEP tumors, the accuracy of SRS appears to be similar to that of bone scintigraphy for the detection of bone metastases.


    • 1 May 1999
      • Vol. 40  (5) , 805-9

    201Tl and 99mTc-MIBI gated SPECT in patients with large perfusion defects and left ventricular dysfunction: comparison with equilibrium radionuclide angiography.

    by A Manrique, M Faraggi, P Véra, D Vilain, R Lebtahi, A Cribier, D Le Guludec

    Left ventricular ejection fraction (LVEF) is a major prognostic factor in coronary artery disease and may be computed by 99mTc-methoxyisobutyl isonitrile (MIBI) gated SPECT. However, 201Tl remains widely used for assessing myocardial perfusion and viability. Therefore, we evaluated the feasibility and accuracy of both 99mTc-MIBI and 201Tl gated SPECT in assessing LVEF in patients with myocardial infarction, large perfusion defects and left ventricular (LV) dysfunction. Fifty consecutive patients (43 men, 7 women; mean age 61 +/- 17 y) with a history of myocardial infarction (anterior, 26; inferior, 18; lateral, 6) were studied. All patients underwent equilibnum radionuclide angiography (ERNA) and rest myocardial gated SPECT, either 1 h after the injection of 1110 MBq 99mTc-MIBI (n = 19, group 1) or 4 h after the injection of 185-203 MBq 201Tl (n = 31, group 2) using a 90 degrees dual-head camera. After filtered backprojection (Butterworth filter: order 5, cutoff 0.25 99mTc or 0.20 201Tl), LVEF was calculated from reconstructed gated SPECT with a previously validated semiautomatic commercially available software quantitative gated SPECT (QGS). Perfusion defects were expressed as a percentage of the whole myocardium planimetered by bull's-eye polar map of composite nongated SPECT. Gated SPECT image quality was considered suitable for LVEF measurement in all patients. Mean perfusion defects were 36% +/- 18% (group 1), 33% +/- 17% (group 2), 34% +/- 17% (group 1 + group 2). LVEF was underestimated using gated SPECT compared with ERNA (34% +/- 12% and 39% +/- 12%, respectively; P = 0.0001). Correlations were high (group 1, r= 0.88; group 2, r = 0.76; group 1 + group 2, r = 0.82), and Bland-Altman plots showed a fair agreement between gated SPECT and ERNA. The difference between the two methods did not vary as LVEF, perfusion defect size or seventy increased or when the mitral valve plane was involved in the defect. LVEF measurement is feasible using myocardial gated SPECT with the QGS method in patients with large perfusion defects and LV dysfunction. However, both 201Tl and 99mTc-MIBI gated SPECT similarly and significantly underestimated LVEF in patients with LV dysfunction and large perfusion defects.