Kenneth E. Nelson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kenneth E. Nelson has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
David D. Hood
Associate Professor
1 shared publicationGreg C. Meister
Fellow
1 shared publicationJ.C. Eisenach
1 shared publicationJames C. Eisenach
Professor
1 shared publicationMichael L. Foss
Fellow. Current position: Department of Anesthesiology, University of Mississippi Medical Center, Jackson, Mississippi
1 shared publicationR. D. D'Angelo
1 shared publication
Latest Publications
- 1 September 2010
- Published by Wolters Kluwer Health in Obstetric Anesthesia Digest
- Vol. 30 (3) , 164-165
Blood Pressure, but Not Cerebrospinal Fluid Fentanyl Concentration, Predicts Duration of Labor Analgesia From Spinal Fentanyl
- 1 September 2010
- Published by Wolters Kluwer Health in Obstetric Anesthesia Digest
- Vol. 30 (3) , 164-165
Blood Pressure, but Not Cerebrospinal Fluid Fentanyl Concentration, Predicts Duration of Labor Analgesia From Spinal Fentanyl
- 1 May 2002
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 96 (5) , 1070-1073
A Comparison of Intrathecal Fentanyl and Sufentanil for Labor Analgesia
Background: The use of intrathecal opioids for labor analgesia continues to gain popularity, but there are limited data to guide this use. Previously, the authors established the ED50 for 60 min of labor analgesia from intrathecal sufentanil using an up-down sequential allocation study design. The current study first establishes an ED50 for intrathecal fentanyl using this same study design to establish an intrathecal potency ratio for fentanyl and sufentanil and then uses this ratio to compare the efficacy, duration of analgesia, and side effects from comparable doses of intrathecal fentanyl and sufentanil. Methods: Seventy-five healthy nulliparous women requesting labor analgesia were enrolled in this two-part study. In phase I, 20 women received varying doses of fentanyl to establish an ED50 for 60 min of labor analgesia. In phase II, 55 women were randomized to receive either 36 microg intrathecal fentanyl or 8 microg sufentanil (2 times the ED50s) via a combined spinal-epidural technique and by double-blinded design. Pain relief, side effects, block height, maternal hemodynamics, and fetal heart rate were assessed throughout the study. The duration of spinal analgesia was considered to be the time from injection of study drug to the time of the patient's first request for additional analgesia. Results: The ED50 of intrathecal fentanyl for 60 min of labor analgesia was found to be 18.2 microg, and therefore, the potency ratio of intrathecal sufentanil to intrathecal fentanyl at the ED50 level is 4.4:1. The duration of spinal analgesia was significantly longer from 8 microg intrathecal sufentanil than from 36 microg intrathecal fentanyl (104 +/- 34 vs. 79 +/- 34 min, P = 0.009). Otherwise, patient demographics, maternal hemodynamics, duration of labor, mode of delivery, motor block, subjective leg weakness, pruritus, nausea, pinprick sensory levels, visual analog scale pain scores, fetal bradycardia, and Apgar scores were similar between groups. Conclusion: The relative potency of intrathecal sufentanil to fentanyl for labor analgesia is 4.4:1. When using intrathecal opioids alone for early labor analgesia, 8 microg sufentanil produces labor analgesia lasting approximately 25 min longer than from 36 microg fentanyl, without a statistically significant increase in side effects. However, when making a choice between fentanyl and sufentanil, one must consider other important factors, such as the higher cost of sufentanil and the greater risk of dosing error due to the higher potency of sufentanil compared with fentanyl.
- 1 May 2002
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 96 (5) , 1070-1073
A Comparison of Intrathecal Fentanyl and Sufentanil for Labor Analgesia
Background: The use of intrathecal opioids for labor analgesia continues to gain popularity, but there are limited data to guide this use. Previously, the authors established the ED50 for 60 min of labor analgesia from intrathecal sufentanil using an up-down sequential allocation study design. The current study first establishes an ED50 for intrathecal fentanyl using this same study design to establish an intrathecal potency ratio for fentanyl and sufentanil and then uses this ratio to compare the efficacy, duration of analgesia, and side effects from comparable doses of intrathecal fentanyl and sufentanil. Methods: Seventy-five healthy nulliparous women requesting labor analgesia were enrolled in this two-part study. In phase I, 20 women received varying doses of fentanyl to establish an ED50 for 60 min of labor analgesia. In phase II, 55 women were randomized to receive either 36 microg intrathecal fentanyl or 8 microg sufentanil (2 times the ED50s) via a combined spinal-epidural technique and by double-blinded design. Pain relief, side effects, block height, maternal hemodynamics, and fetal heart rate were assessed throughout the study. The duration of spinal analgesia was considered to be the time from injection of study drug to the time of the patient's first request for additional analgesia. Results: The ED50 of intrathecal fentanyl for 60 min of labor analgesia was found to be 18.2 microg, and therefore, the potency ratio of intrathecal sufentanil to intrathecal fentanyl at the ED50 level is 4.4:1. The duration of spinal analgesia was significantly longer from 8 microg intrathecal sufentanil than from 36 microg intrathecal fentanyl (104 +/- 34 vs. 79 +/- 34 min, P = 0.009). Otherwise, patient demographics, maternal hemodynamics, duration of labor, mode of delivery, motor block, subjective leg weakness, pruritus, nausea, pinprick sensory levels, visual analog scale pain scores, fetal bradycardia, and Apgar scores were similar between groups. Conclusion: The relative potency of intrathecal sufentanil to fentanyl for labor analgesia is 4.4:1. When using intrathecal opioids alone for early labor analgesia, 8 microg sufentanil produces labor analgesia lasting approximately 25 min longer than from 36 microg fentanyl, without a statistically significant increase in side effects. However, when making a choice between fentanyl and sufentanil, one must consider other important factors, such as the higher cost of sufentanil and the greater risk of dosing error due to the higher potency of sufentanil compared with fentanyl.
- Open Access
- 1 April 2000
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 2000 (4)
A Comparison Of Intrathecal Fentanyl And Sufentanil For Labor Analgesia
- 1 April 2000
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 2000 (4)
Open AccessA Comparison Of Intrathecal Fentanyl And Sufentanil For Labor Analgesia
- 1 November 1999
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 91 (5) , 1293
Intrathecal Neostigmine and Sufentanil for Early Labor Analgesia
Background: Recent efforts to improve the combined spinal epidural (CSE) technique have focused on adding opioids to other classes of analgesics. In this study, the authors used intrathecal neostigmine in combination with intrathecal sufentanil to investigate the usefulness of neostigmine for reducing side effects and prolonging the duration of sufentanil. Methods: One hundred six healthy pregnant women in labor were enrolled in this study, which was divided into four phases. In all phases, patients received a CSE anesthetic while in the lateral position. In phase I, three groups of six women each received intrathecal neostigmine, 5, 10, or 20 microg, in an open-label, dose-escalating safety assessment. In phase II, 24 women received intrathecal sufentanil alone to establish an ED50 (dose that produces > 60 min of labor analgesia in 50% of patients). In phase III, an ED50 was established for sufentanil combined with a fixed dose of neostigmine (10 microg). In phase IV, 40 women received either twice the ED50 of sufentanil alone or twice the ED50 of sufentanil plus neostigmine, 10 microg. Results: Neostigmine alone had no adverse effects on maternal vital signs, fetal heart rate, or Apgar scores. Neostigmine, 20 microg, produced analgesia in one patient and severe nausea and vomiting in another. The ED50 for intrathecal sufentanil alone was 4.1 +/- 0.31 microg, and the ED50 for intrathecal sufentanil combined with neostigmine, 10 microg, was 3.0 +/- 0.28 microg. The duration of analgesia and side effects from double these ED50s (sufentanil, 9 microg, or sufentanil, 6 microg, plus neostigmine, 10 microg) were similar between groups. Conclusions: The 10-microg intrathecal neostigmine dose alone produced no analgesia or side effects, but reduced the ED50 of intrathecal sufentanil by approximately 25%. Additionally, doses approximately double these ED50s each produced a similar duration of analgesia and side effects, indicating intrathecal neostigmine shifts the dose-response curve for intrathecal sufentanil to the left.
- 1 November 1999
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 91 (5) , 1293
Intrathecal Neostigmine and Sufentanil for Early Labor Analgesia
Background: Recent efforts to improve the combined spinal epidural (CSE) technique have focused on adding opioids to other classes of analgesics. In this study, the authors used intrathecal neostigmine in combination with intrathecal sufentanil to investigate the usefulness of neostigmine for reducing side effects and prolonging the duration of sufentanil. Methods: One hundred six healthy pregnant women in labor were enrolled in this study, which was divided into four phases. In all phases, patients received a CSE anesthetic while in the lateral position. In phase I, three groups of six women each received intrathecal neostigmine, 5, 10, or 20 microg, in an open-label, dose-escalating safety assessment. In phase II, 24 women received intrathecal sufentanil alone to establish an ED50 (dose that produces > 60 min of labor analgesia in 50% of patients). In phase III, an ED50 was established for sufentanil combined with a fixed dose of neostigmine (10 microg). In phase IV, 40 women received either twice the ED50 of sufentanil alone or twice the ED50 of sufentanil plus neostigmine, 10 microg. Results: Neostigmine alone had no adverse effects on maternal vital signs, fetal heart rate, or Apgar scores. Neostigmine, 20 microg, produced analgesia in one patient and severe nausea and vomiting in another. The ED50 for intrathecal sufentanil alone was 4.1 +/- 0.31 microg, and the ED50 for intrathecal sufentanil combined with neostigmine, 10 microg, was 3.0 +/- 0.28 microg. The duration of analgesia and side effects from double these ED50s (sufentanil, 9 microg, or sufentanil, 6 microg, plus neostigmine, 10 microg) were similar between groups. Conclusions: The 10-microg intrathecal neostigmine dose alone produced no analgesia or side effects, but reduced the ED50 of intrathecal sufentanil by approximately 25%. Additionally, doses approximately double these ED50s each produced a similar duration of analgesia and side effects, indicating intrathecal neostigmine shifts the dose-response curve for intrathecal sufentanil to the left.