ASAshok Sethi

Ashok Sethi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ashok Sethi has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Managing the Edentulous Mandible using Recent Technological Developments: A Case Study

    by Ashok Sethi, Thomas Kaus, Naresh Sharma, Peter Sochor

    Safe clinical practice in implant dentistry requires an accurate investigation of the availability of bone for implant placement and the avoidance of critical anatomical structures. Modern imaging techniques using computed tomography (CT) and cone beam computed tomography (CBCT) provide the clinician with the required information. The imaging thus obtained provides accurate representation of the height, width and length of the available bone.1 In addition, whenever adequate radiation dose is used, accurate information about the bone density in Hounsfield units can be obtained. Important spatial information regarding the orientation of the ridges and the relationship to the proposed prosthetic reconstruction can be obtained with the aid of radiopaque templates during the acquisition of CT scan data. Modern software also provides the facility to decide interactively upon the positioning of the implants and is able to relate this to a stereolithographic model constructed from the imaging data. A surgical guide for the accurate positioning of the implants can be constructed. The construction of screw retained prostheses is fraught with difficulties regarding the accuracy of the construction. Accurate fit of the prosthesis is difficult to obtain due to the inherent errors in impression taking, component discrepancies, investing and casting inaccuracies.2,3 CAD/CAM technology eliminates the inaccuracies involved with the investing and casting of superstructures. Clinical Case: This case describes the management of an 84 year old female patient, who had recently lost her remaining mandibular anterior teeth. This resulted in the patient's inability to wear conventional dentures in the mandible.


  • Hong Kong craniofacial dissection workshop: a first for FGDP(UK)'s implant dentistry diploma

    by Vishy Mahadevan, Ashok Sethi

    The diploma in implant dentistry, one of many successful educational programmes developed by the FGDP(UK), comprises 16 weekend units of study culminating in a rigorous assessment. Integral to the course is a craniofacial anatomy module, in which under supervision the participants perform a sequence of detailed dissections on cadaver heads, with a view to reinforcing their understanding of surgical anatomy relevant to general and implant dentistry. Interspersed with the dissection sessions are five or six tutorials, each intended as a prelude to the dissection exercise.

  • Clinical performance of Rochette bridges used as immediate provisional restorations for single unit implants in general practice

    by S Banerji, A Sethi, S M Dunne, B J Millar

    The role of the BDJ is to inform its readers of ideas, opinions, developments and key issues in dentistry - clinical, practical and scientific - stimulating interest, debate and discussion amongst dentists of all disciplines.


  • Evolution of the Concept of Angulated Abutments in Implant Dentistry:14-year Clinical Data

    by Ashok Sethi, Thomas Kaus, Peter Sochor, Detlef Axmann-Krcmar, Manuel Chanavaz

    This paper describes the evolution of the concept of selecting the abutment at first-stage surgery and presents clinical data accumulated over 14 years of the use of this concept with angulated abutments. The concept was developed for implants using internal and external hexed connections and has evolved in its use for implants using a Morse taper connection as a result of the considerable clinical advantages that this type of connection offers. A total of 3101 implants were restored using angled abutments ranging from 0 to 45 degrees and were observed over a period of up to 151 months. After an observation time of 120 months (10 years) after placement, the calculated 95% confidence interval of the mean survival estimation, according to Aalen et al, was 98.2% (± 0.7%). 16 The magnitude of the angles did not influence the survival rate. The need to refine the implant position in terms of the depth to which it was placed and the angulation and rotational orientation, as well as the size and pivot point of the final abutment, were recognized as contributing to the harmonious emergence profile of the restoration. Good esthetic and functional outcomes were achieved by the use of conventional cement-retained restorations made possible by parallel and aligned abutments.


    • 4 July 2001
      • Vol. 16  (3) , 378-88

    Ridge augmentation using mandibular block bone grafts: preliminary results of an ongoing prospective study.

    by A Sethi, T Kaus

    The aim of the current ongoing study is to evaluate the long-term results of endosseous implants placed into autogenous bone grafts from intraoral donor sites. Patient selection for the correction of bone deficiencies was based on biomechanical and esthetic needs. Donor site selection was dependent upon the type of deficiency and the graft shape needed. Two-stage implants were placed after a healing period of 3 to 6 months, based on an assessment of the graft viability with radiographic and clinical parameters. Thus far, 118 implants have been placed in 60 patients whose alveolar ridges were deficient in height, width, or both height and width and were augmented. The patients were observed for up to 77 months. Two implant failures were encountered before implant exposure (1.7%). No further implants have been lost in function.


    • 11 January 2001
      • Vol. 15  (6) , 801-10

    The use of angulated abutments in implant dentistry: five-year clinical results of an ongoing prospective study.

    by A Sethi, T Kaus, P Sochor

    A total of 2,261 2-stage implants was placed in 467 patients in combination with angled abutments ranging from 0 to 45 degrees. These were observed over a period of up to 96 months, with a mean observation time of 28.8 months. Single and multiple teeth were replaced and restored using angled abutments. For patients who contributed multiple survival data, the data were considered dependent. Therefore, a mean survival estimation was performed. With a certainty of 95%, an estimated mean survival rate better than 98.6% after a 5-year observation period was calculated. The statistical comparison of 2 independent, randomized implant groups (with abutments angled between 0 and 15 degrees and between 20 and 45 degrees) by means of a log-rank test showed a probability of 0.84 (P value) that the survival functions are the same for both groups. Good esthetic and functional outcomes were observed.


    • 29 August 2000
      • Vol. 15  (4) , 491-9

    Maxillary ridge expansion with simultaneous implant placement: 5-year results of an ongoing clinical study.

    by A Sethi, T Kaus

    With the technique of maxillary ridge expansion, 449 implants were placed in 150 patients and observed over a period of up to 93 months. Thin maxillary ridges of adequate height and comprising 2 separate cortical plates with intervening cancellous bone were selected for maxillary ridge expansion and simultaneous implant placement. Two-stage implants were used and allowed to heal in a closed environment for 6 months prior to loading. Single and multiple teeth were replaced using this technique, and an estimated mean survival rate better than 97% after a 5-year observation period was calculated (95% confidence interval of the mean survival estimation: 98% +/- 1%). Good esthetic and functional outcomes were observed.


    • 1 March 2000
      • Vol. 8  (1) , 39-43

    The lateral fixation screw in implant dentistry.

    by A Sethi, P Sochor

    This clinical report presents a means of retaining implant supported superstructures using lateral fixation screws (Novadent). 244 lateral fixation screws have been used for the retention of a variety of restorations including single teeth, short span and full arch bridgework as well as overdenture bars. Over a period of observation of 4 years, the authors have found the restorations to have effective retention, ease of retrievability, good aesthetics and occlusal contours.


    • 1 March 1996
      • Vol. 4  (1) , 21-8

    Initial results of the Osteo Ti implant system in general dental practice.

    by A Sethi, S Harding, P Sochor

    It is the purpose of this paper to present the preliminary results of 370 consecutively placed Osieo-Ti implants. Two stage screw form endosseous implants ranging in length from 7mm to 20mm in one mm increments were used. Four diameters of implant 2.75mm, 3.00mm, 3.75mm and 4.50mm were used to engage the maximum available width of bone. The larger, 3.75mm and 4.50mm diameter, implants were made from commercially pure titanium and the two smaller diameter, 2.75mm and 3.00mm, implants were manufactured from titanium alloy. The overall success rate for 370 exposed functioning Osteo-Ti implants was 98.6%.