Mark S Nelson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mark S Nelson has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
As Amin
The Bode Technology Group (TBTG) 3 , Springfield, VA
1 shared publicationBe Early
North Carolina State Bureau of Investigation (NCSBI) 1 , Raleigh, NC
1 shared publicationCa Kuhn
North Carolina State Bureau of Investigation (NCSBI) 1 , Raleigh, NC
1 shared publicationCj Sprecher
Promega Corporation (PC) 2 , Madison, WI
1 shared publicationDA Freeman
North Carolina State Bureau of Investigation (NCSBI) 1 , Raleigh, NC
1 shared publicationEn Levedakou
North Carolina State Bureau of Investigation (NCSBI) 1 , Raleigh, NC
1 shared publication
Latest Publications
- 1 March 2002
- Published by ASTM International in Journal of Forensic Sciences
- Vol. 47 (2) , 345-349
Detection of a Primer-Binding Site Polymorphism for the STR Locus D16S539 Using the Powerplex® 1.1 System and Validation of a Degenerate Primer to Correct for the Polymorphism
Quality assurance samples submitted from the NCSBI as part of a contract with TBTG to outsource DNA Database samples showed unexpected discrepancies for the locus D16S539 when all other loci yielded identical results. Discrepancies observed included allele drop out and an imbalance in sister alleles with samples returned from TBTG. This led to a comprehensive review of the technical procedures used between the two laboratories to determine the cause of the discrepancies noted for the locus D16S539, since both laboratories were using the PowerPlex® 1.1 typing kit from the Promega Corporation. The NCSBI and the TBTG utilize different extraction methods (organic extraction vs. FTA) and amplification conditions (AmpliTaq® vs AmpliTaq Gold®), respectively, so the exact cause of discrepancy observed was not immediately apparent. Experiments at the NCSBI associated the observed allele drop out and the imbalance of the sister alleles with the use of AmpliTaq Gold® and a hot start procedure. Sequencing data revealed that a point mutation resides on the D16S539 primer-binding site that reaches polymorphic levels in African-American populations. This led to the development of a degenerate primer by the Promega Corporation to detect “missing” alleles when AmpliTaq Gold® is used. The degenerate primer was then thoroughly tested to show its efficacy in detecting the “true” D16S539 profile when used.
- 1 March 2002
- Published by ASTM International in Journal of Forensic Sciences
- Vol. 47 (2) , 345-349
Detection of a Primer-Binding Site Polymorphism for the STR Locus D16S539 Using the Powerplex® 1.1 System and Validation of a Degenerate Primer to Correct for the Polymorphism
Quality assurance samples submitted from the NCSBI as part of a contract with TBTG to outsource DNA Database samples showed unexpected discrepancies for the locus D16S539 when all other loci yielded identical results. Discrepancies observed included allele drop out and an imbalance in sister alleles with samples returned from TBTG. This led to a comprehensive review of the technical procedures used between the two laboratories to determine the cause of the discrepancies noted for the locus D16S539, since both laboratories were using the PowerPlex® 1.1 typing kit from the Promega Corporation. The NCSBI and the TBTG utilize different extraction methods (organic extraction vs. FTA) and amplification conditions (AmpliTaq® vs AmpliTaq Gold®), respectively, so the exact cause of discrepancy observed was not immediately apparent. Experiments at the NCSBI associated the observed allele drop out and the imbalance of the sister alleles with the use of AmpliTaq Gold® and a hot start procedure. Sequencing data revealed that a point mutation resides on the D16S539 primer-binding site that reaches polymorphic levels in African-American populations. This led to the development of a degenerate primer by the Promega Corporation to detect “missing” alleles when AmpliTaq Gold® is used. The degenerate primer was then thoroughly tested to show its efficacy in detecting the “true” D16S539 profile when used.