Hailemichael Alemu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hailemichael Alemu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Potlaki F. Tseki
Department of Chemistry, National University of Lesotho, P.O. Roma 180, Roma, Lesotho, Southern Africa
2 shared publicationsBerhanu M. Abegaz
Department of Chemistry University of Botswana P/Bag 00704 Gaborone Botswana
1 shared publication- Himanshu Narayan
Faculty of Science & Technology, National University of Lesotho, Roma 180, Lesotho
1 shared publication - Lebohang Hlalele
Preparative Macromolecular Chemistry, Institut für Technische Chemie und Polymerchemie, Karlsruhe Institute of Technology (KIT), Engesserstr. 18, 76128 Karlsruhe, Germany
1 shared publication - Lebohang Macheli
Department of Chemistry & Chemical Technology, National University of Lesotho, Roma 180, Lesotho
1 shared publication Lijeloang Setofolo
Department of Chemistry & Chemical Technology, National University of Lesotho, Roma 180, Lesotho
1 shared publication
Latest Publications
- Open Access
- 1 January 2014
- Published by Wiley in International Scholarly Research Notices
- Vol. 2014, 1-10
Determination of Phenol and Chlorophenols at Single-Wall Carbon Nanotubes/Poly(3,4-ethylenedioxythiophene) Modified Glassy Carbon Electrode Using Flow Injection Amperometry
Phenol and chlorophenols were investigated using single-wall carbon nanotubes (SWCNT) and poly(3,4-ethylenedioxythiophene) (PEDOT) composite modified glassy carbon electrode (SWCNT/PEDOT/GCE) as a detector in flow injection system. Optimization of experimental variables such as the detection potential, flow rate, and pH of the carrier solution (0.1 M sodium acetate) for the determination of phenol (P), 4-chlorophenol (CP), 2,4-dichlorophenol (DCP), 2,4,6-trichlorophenol (TCP), and pentachlorophenol (PCP) were performed. Under these conditions, analytical parameters were calculated from the calibration curve of measured amperometric responses as a function of concentrations of phenol and chlorophenols. The designed electrode exhibited very good analytical performance. The designed electrode was tested with 20 repetitive injections of each analyte and showed good operational stability. The analytical performance of the SWCNT/PEDOT/GCE electrode under flow through conditions was tested and was found to be impressive. The electrode showed a wider dynamic range for the detection of phenol and chlorophenols with low limits of detection compared with other enzymatic and nonenzymatic sensors. These results suggest that the method is quite useful for the analysis and monitoring of phenols and chlorophenols.
- 1 January 2014
- Published by Wiley in International Scholarly Research Notices
- Vol. 2014, 1-10
Open AccessDetermination of Phenol and Chlorophenols at Single-Wall Carbon Nanotubes/Poly(3,4-ethylenedioxythiophene) Modified Glassy Carbon Electrode Using Flow Injection Amperometry
Phenol and chlorophenols were investigated using single-wall carbon nanotubes (SWCNT) and poly(3,4-ethylenedioxythiophene) (PEDOT) composite modified glassy carbon electrode (SWCNT/PEDOT/GCE) as a detector in flow injection system. Optimization of experimental variables such as the detection potential, flow rate, and pH of the carrier solution (0.1 M sodium acetate) for the determination of phenol (P), 4-chlorophenol (CP), 2,4-dichlorophenol (DCP), 2,4,6-trichlorophenol (TCP), and pentachlorophenol (PCP) were performed. Under these conditions, analytical parameters were calculated from the calibration curve of measured amperometric responses as a function of concentrations of phenol and chlorophenols. The designed electrode exhibited very good analytical performance. The designed electrode was tested with 20 repetitive injections of each analyte and showed good operational stability. The analytical performance of the SWCNT/PEDOT/GCE electrode under flow through conditions was tested and was found to be impressive. The electrode showed a wider dynamic range for the detection of phenol and chlorophenols with low limits of detection compared with other enzymatic and nonenzymatic sensors. These results suggest that the method is quite useful for the analysis and monitoring of phenols and chlorophenols.
- Open Access
- 1 March 2012
- Published by Wiley in ISRN Physical Chemistry
- Vol. 2012, 1-9
Visible Light Photocatalysis with Rare Earth Ion-Doped Nanocomposites
Rare earth (R) ion-doped TiO2 nanocomposites (NCs) with general composition (R: Y, Yb, Gd; , 0.2) were synthesized through co-precipitation/hydrolysis (CPH). NC particles with average size of approximately a few tens of nm were obtained. Similar compositions of polycrystalline (PC) samples with larger particle size were also prepared employing solid state reaction (SSR) method. Visible light photocatalytic activity of all samples was investigated for degradation of Congo red (CR) dye. Both in terms of apparent rate constant () and percent degradation after 180 min (), all NCs produced significantly enhanced degradation as compared to pure TiO2 and PC samples. Best degradation of 95% ( value) resulted with composition of Y3+ doped NC with min−1. This was followed by of 85 and 80%, produced with Yb3+ and Gd3+ doped, NCs, at around and min−1, respectively. The observations clearly suggest that enhanced photocatalytic degradation of CR is directly related to smaller particle size of the catalysts. Moreover, the presence of rare earth ions in the composites facilitates further improvement of degradation efficiency through effective suppression of recombination.
- 1 March 2012
- Published by Wiley in ISRN Physical Chemistry
- Vol. 2012, 1-9
Open AccessVisible Light Photocatalysis with Rare Earth Ion-Doped Nanocomposites
Rare earth (R) ion-doped TiO2 nanocomposites (NCs) with general composition (R: Y, Yb, Gd; , 0.2) were synthesized through co-precipitation/hydrolysis (CPH). NC particles with average size of approximately a few tens of nm were obtained. Similar compositions of polycrystalline (PC) samples with larger particle size were also prepared employing solid state reaction (SSR) method. Visible light photocatalytic activity of all samples was investigated for degradation of Congo red (CR) dye. Both in terms of apparent rate constant () and percent degradation after 180 min (), all NCs produced significantly enhanced degradation as compared to pure TiO2 and PC samples. Best degradation of 95% ( value) resulted with composition of Y3+ doped NC with min−1. This was followed by of 85 and 80%, produced with Yb3+ and Gd3+ doped, NCs, at around and min−1, respectively. The observations clearly suggest that enhanced photocatalytic degradation of CR is directly related to smaller particle size of the catalysts. Moreover, the presence of rare earth ions in the composites facilitates further improvement of degradation efficiency through effective suppression of recombination.
- Open Access
- 10 July 2007
- Published by African Journals Online (AJOL) in Bulletin of the Chemical Society of Ethiopia
- Vol. 21 (2) , 189-204
ELECTROCHEMICAL BEHAVIOUR AND VOLTAMMETRIC DETERMINATION OF GESHOIDIN AND ITS SPECTROPHOTOMETRIC AND ANTIOXIDANT PROPERTIES IN AQUEOUS BUFFER SOLUTIONS
ELECTROCHEMICAL BEHAVIOUR AND VOLTAMMETRIC DETERMINATION OF GESHOIDIN AND ITS SPECTROPHOTOMETRIC AND ANTIOXIDANT PROPERTIES IN AQUEOUS BUFFER SOLUTIONS
- 10 July 2007
- Published by African Journals Online (AJOL) in Bulletin of the Chemical Society of Ethiopia
- Vol. 21 (2) , 189-204
Open AccessELECTROCHEMICAL BEHAVIOUR AND VOLTAMMETRIC DETERMINATION OF GESHOIDIN AND ITS SPECTROPHOTOMETRIC AND ANTIOXIDANT PROPERTIES IN AQUEOUS BUFFER SOLUTIONS
ELECTROCHEMICAL BEHAVIOUR AND VOLTAMMETRIC DETERMINATION OF GESHOIDIN AND ITS SPECTROPHOTOMETRIC AND ANTIOXIDANT PROPERTIES IN AQUEOUS BUFFER SOLUTIONS
- Open Access
- 30 April 2007
- Published by African Journals Online (AJOL) in Bulletin of the Chemical Society of Ethiopia
- Vol. 21 (1)
Voltammetric determination of chloramphenicol at electrochemically pretreated glassy carbon electrode
Voltammetric determination of chloramphenicol at electrochemically pretreated glassy carbon electrode
- 30 April 2007
- Published by African Journals Online (AJOL) in Bulletin of the Chemical Society of Ethiopia
- Vol. 21 (1)
Open AccessVoltammetric determination of chloramphenicol at electrochemically pretreated glassy carbon electrode
Voltammetric determination of chloramphenicol at electrochemically pretreated glassy carbon electrode
- Open Access
- 1 January 2003
- Published by African Journals Online (AJOL) in Bulletin of the Chemical Society of Ethiopia
- Vol. 17 (1)
Electrochemical oxidation of niclosamide at a glassy carbon electrode and its determination by voltammetry
Electrochemical oxidation of niclosamide at a glassy carbon electrode and its determination by voltammetry
- 1 January 2003
- Published by African Journals Online (AJOL) in Bulletin of the Chemical Society of Ethiopia
- Vol. 17 (1)
Open AccessElectrochemical oxidation of niclosamide at a glassy carbon electrode and its determination by voltammetry
Electrochemical oxidation of niclosamide at a glassy carbon electrode and its determination by voltammetry
- 11 December 2001
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 127 (1) , 129-134
Voltammetric determination of niclosamide at a glassy carbon electrodeThis paper was submitted for inclusion in the New Directions in Electroanalysis Guest Editor Issue of The Analyst.
A very sensitive and selective procedure was developed for the determination of niclosamide based on square-wave voltammetry at a glassy carbon electrode. Cyclic voltammetry was used to investigate the electrochemical reduction of niclosamide at a glassy carbon electrode. Niclosamide was first irreversibly reduced from NO2 to NHOH at −0.659 V in aqueous buffer solution of pH 8.5. Reversible and well defined peaks at −0.164 V and −0.195 V (vs. Ag/AgCl) were obtained that are responsible for two electron peaks between NHOH and NO. Following optimisation of the voltammetric parameters, pH and reproducibility, a linear calibration curve over the range 5 × 10−8–1 × 10−6 mol dm−3 was achieved. The detection limit was found to be 2.05 × 10−8 mol dm−3 niclosamide. For eight successive determinations of 5 × 10−7 mol dm−3 niclosamide, a relative standard deviation of 2.4% was obtained. This voltammetric method was applied to the direct determination of niclosamide in tablets. The results of the analysis suggest that the proposed method has promise for the routine determination of niclosamide in the products examined.
- 11 December 2001
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 127 (1) , 129-134
Voltammetric determination of niclosamide at a glassy carbon electrodeThis paper was submitted for inclusion in the New Directions in Electroanalysis Guest Editor Issue of The Analyst.
A very sensitive and selective procedure was developed for the determination of niclosamide based on square-wave voltammetry at a glassy carbon electrode. Cyclic voltammetry was used to investigate the electrochemical reduction of niclosamide at a glassy carbon electrode. Niclosamide was first irreversibly reduced from NO2 to NHOH at −0.659 V in aqueous buffer solution of pH 8.5. Reversible and well defined peaks at −0.164 V and −0.195 V (vs. Ag/AgCl) were obtained that are responsible for two electron peaks between NHOH and NO. Following optimisation of the voltammetric parameters, pH and reproducibility, a linear calibration curve over the range 5 × 10−8–1 × 10−6 mol dm−3 was achieved. The detection limit was found to be 2.05 × 10−8 mol dm−3 niclosamide. For eight successive determinations of 5 × 10−7 mol dm−3 niclosamide, a relative standard deviation of 2.4% was obtained. This voltammetric method was applied to the direct determination of niclosamide in tablets. The results of the analysis suggest that the proposed method has promise for the routine determination of niclosamide in the products examined.