RMRobert Montés-Micó

Robert Montés-Micó

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Robert Montés-Micó has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Contrast Sensitivity After LASIK Flap Creation With a Femtosecond Laser and a Mechanical Microkeratome

    by Robert Montés-Micó, Antonio Rodríguez-Galietero, Jorge L. Alió, Alejandro Cerviño

    Purpose: To compare the effects on contrast sensitivity of the IntraLase femtosecond laser for flap creation (IntraLASIK) and standard LASIK for myopia. Methods: Two hundred eyes of 100 consecutive patients underwent LASIK treatment using the VISX S2 laser system. The femtosecond laser (15 kHz IntraLase) was used for flap creation in 100 eyes (50 patients) and a mechanical microkeratome (Carriazo-Barraquer) was used in 100 eyes (50 patients). Best spectacle-corrected contrast sensitivity was measured before and 6 months postoperatively in the IntraLASIK and mechanical LASIK groups. The IntraLASIK and mechanical LASIK-induced changes in contrast sensitivity were compared under photopic (85 cd/m 2 ) and mesopic (5, 2.5, and 0.1 cd/m 2 ) conditions. Results: Contrast sensitivity for eyes after IntraLASIK did not differ from preoperative values at the photopic level (85 cd/m 2 ). However, under mesopic conditions, a statistically significant reduction ( P >.01) in contrast sensitivity was found at high spatial frequencies (12 and 18 cpd), although no significant contrast sensitivity differences were observed at low and middle spatial frequencies ( P <.01 for 1.5, 3, and 6 cpd). No statistically significant differences were found between IntraLASIK and mechanical LASIK for 1.5, 3, and 6 cpd at any luminance level ( P <.01). IntraLASIK showed better contrast sensitivity than mechanical LASIK under mesopic conditions at 12 cpd and photopic and mesopic conditions at 18 cpd ( P >.01). Conclusions: IntraLASIK surgery demonstrated better contrast sensitivity at high spatial frequencies under photopic and mesopic conditions than mechanical LASIK. [ J Refract Surg . 2007;23:188–192.]


  • Femtosecond Laser versus Mechanical Keratome LASIK for Myopia

    by Robert Montés-Micó, Antonio Rodríguez-Galietero, Jorge L. Alió


  • Dynamic Changes in the Tear Film in Dry Eyes

    by Robert Monte´s-Mico´, Jorge L. Alio´, W. Neil Charman

    Purpose. To examine the dynamics of the tear film in patients with dry eye by measuring the wavefront aberrations of the anterior surface of the film. methods. Anterior surface aberrations for a 7-mm pupil were determined in 13 patients with dry eye at 1-second time intervals, for 15 seconds after a blink. The aberrations were calculated from the elevations provided by corneal topography. All data were decomposed using Zernike polynomials. Total, spherical, and comalike aberrations terms were studied separately. Results were compared with those in normal eyes. Outcome measures included comparison with clinical tear breakup time measurements. results. The total root mean square (RMS) wavefront aberration in patients with dry eye passed through in a minimum of 2.9 ± 0.4 seconds after a blink in comparison to the minimum at 6.1 ± 0.5 seconds in normal patients. In both groups, the minimum in total aberration appeared to be associated with similar changes in comalike aberrations, rather than in spherical aberrations, which increased monotonically with time. The time at which minimum RMS aberration occurred correlated reasonably well with the measured tear breakup times. conclusions. Measurements of the dynamic changes in the optical aberrations introduced by the anterior tear film surface give valuable insights into tear film changes and may provide a convenient objective method for the diagnosis of dry eye.


  • Changes in ocular aberrations after instillation of artificial tears in dry-eye patients

    by Robert Montés-Micó, Araceli Cáliz, Jorge L Alió

    To study the effect of artificial tear instillation on ocular aberrations in dry-eye patients. Research, Development and Innovation Department, Instituto Oftalmológico de Alicante, Alicante, Spain. Ocular aberrations (total, spherical-like, and coma-like) were measured with a Hartmann-Shack aberrometer before and after artificial tear instillation (immediately and 10 minutes later) in 15 eyes of 15 dry-eye patients. Optical aberrations showed a statistically significant reduction after artificial tear instillation (P<.01). Total aberrations decreased on average by a factor of 2 to 3 times immediately after instillation; the reduction was maintained after 10 minutes (P>.01). After artificial tear instillation, the reduction in optical aberrations associated with an increasingly irregular tear film may cause an improvement in the optical quality of dry eyes. Wavefront analysis facilitates the evaluation of improvement in optical quality after artificial tear instillation in patients with dry eye.


  • Corneal aberrations after astigmatic keratotomy combined with laser in situ keratomileusis

    by Robert Montés-Micó, Gonzalo Muñoz, César Albarrán-Diego, Antonio Rodríguez-Galietero, Jorge L Alió

    To evaluate the optical aberrations in the cornea before and after astigmatic keratotomy (AK) combined with laser in situ keratomileusis (LASIK) in a group of patients with high myopic astigmatism. Refractive Surgery Unit, NISA Hospital Virgen del Consuelo, Valencia, Spain. Twelve patients (24 eyes) with high myopic astigmatism (from 3.50 to 6.00 diopters) participated in the study. Astigmatic keratotomy was performed as the first step to reduce astigmatism; after 2 months, the residual refractive error was corrected with LASIK. Videokeratography measurements were conducted before and after each procedure. Topography maps were used to calculate the wavefront corneal aberrations for a 6.0 mm pupil diameter. Total, coma-like, and spherical-like aberrations increased significantly from preoperatively to post LASIK (x6.34, x2.52, and x10.50, respectively; P<.01). Astigmatic keratotomy significantly increased coma-like (x4.04; P<.01) and spherical-like (x5.66; P<.01) aberrations. After LASIK, the coma-like aberration was significantly reduced (x0.62; P =.008) and the spherical-like aberration was significantly increased (x1.86; P<.01). Astigmatic keratotomy increased higher-order corneal aberrations, both coma-like and spherical-like, whereas LASIK performed after AK increased the spherical-like aberration and reduced the coma-like aberration.


  • Temporal Changes in Optical Quality of Air–Tear Film Interface at Anterior Cornea after Blink

    by Robert Monte´s-Mico´, Jorge L. Alio´, Gonzalo Mun~Oz, W. Neil Charman

    Purpose. To examine temporal changes in the optical quality of the air–tear film interface at the anterior cornea after a blink. methods. Corneal aberrations were determined in fifteen healthy subjects at 1 second time intervals after a blink, up to a total elapsed time of 15 seconds. Corneal aberrations were obtained from corneal elevation maps measured using a Tomey TMS-2N topographer and custom software. All data were decomposed using Zernike polynomials to yield the root mean square (RMS) wavefront deviations, in micrometers, for two pupil diameters (3 and 7 mm). results. Total wavefront aberration decreased slightly with time in the first few seconds after a blink for both pupil diameters, reaching a minimum after approximately 6 seconds. Thereafter aberrations increased steadily, exceeding the immediate postblink level after approximately 10 seconds. conclusions. In normal subjects, the contribution of the anterior cornea to the overall ocular aberration remains reasonably stable over the normal interblink interval (approximately 4 seconds) but rises to levels which could perceptibly degrade retinal image quality under circumstances where the interblink interval is increased to exceed 10 seconds, as may occur during the use of visual display screens or when performing difficult tasks.


  • Wavefront Analysis of Higher Order Aberrations in Dry Eye Patients

    by Robert Montés-Micó, Araceli Cáliz, Jorge L Alió

    PURPOSE: To compare ocular wavefront aberrations of normal and dry eyes and to describe the characteristics of higher order aberration in dry eyes. METHODS: Wavefront analysis of higher order ocular aberrations (total S^sub 3+4+5^, spherical-like S 4 , coma-like S^sub 3+5^) was performed with a HartmannShack aberrometer in 20 dry eyes and 20 normal control eyes. RESULTS: Total, spherical-like, and coma-like aberrations were significantly greater in dry eyes than in normal controls (P<.01) both for a 4-mm (total S^sub 3+4^: factor of 2.58; spherical S 4 : factor of 2.50; coma S 3 : factor of 2.70) and 6-mm-diameter pupil (S^sub 3+4+5^: factor of 2.29, S 4 : x2.53, and S^sub 3+5^: factor of 2.40). CONCLUSIONS: Eyes of dry eye patients showed greater optical aberrations compared with normal control eyes. Increase in higher order aberrations in dry eyes resulted from increased tear film irregularity. [J Refract Surg 2004;20:243-247]


  • Visual performance with multifocal intraocular lenses

    by Robert Montés-Micó, Enrique España, Inmaculada Bueno, W.NEil Charman, José L Menezo