SOSadettin S. Ozturk

Sadettin S. Ozturk

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sadettin S. Ozturk has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • D. Naveh

    Bayer Corporation-Biotechnology, 4th & Parker St., P.O. Box 1986, Berkeley, CA 94701

    1 shared publication
  • J. C. Thrift

    Bayer Corporation-Biotechnology, 4th & Parker St., P.O. Box 1986, Berkeley, CA 94701

    1 shared publication
  • J. D. Blackie

    Bayer Corporation-Biotechnology, 4th & Parker St., P.O. Box 1986, Berkeley, CA 94701

    1 shared publication
  • Parisa Jorjani

    Bayer Corporation, Biotechnology Unit, 800 Dwight Way, Berkeley, California 94701, USA

    1 shared publication

Latest Publications

  • Effects of cell density and temperature on oxygen consumption rate for different mammalian cell lines

    by Parisa Jorjani, Sadettin S. Ozturk

    Oxygen consumption rates were measured in a respirometer for different mammalian cell lines (BHK, murine hybridoma, and CHO), and the effects of cell density (1–20 million cells/mL) and temperature (6 to 37°C) on specific oxygen consumption rate were investigated. The specific oxygen consumption was cell line dependent. For a given temperature, the murine hybridoma cells had the lowest and the CHO cells had the highest oxygen consumption rate. The specific oxygen consumption rate was not affected by the cell concentration for cell densities between 1 and 20 million cells/mL. However, artificial trends implicating the effects of cell density were obtained when traditional analysis was used and the probe response time was neglected. A detailed mathematical analysis was presented to investigate the magnitude of errors originating from neglecting the probe response time for the calculation of oxygen consumption rate. The error was significant, especially when the probe response was slow and/or the oxygen consumption was fast. Temperature influenced the specific oxygen consumption rate similarly for the cells studied, and about 10% decrease was observed in specific oxygen consumption by 1°C decrease in the temperature. Between 6 and 37°C, the effect of temperature on oxygen consumption rate could be described using an Arrhenius model, i.e., q = q2 · e−E/RT. The activation energy, E, in this equation was similar for different cells (between 80 and 90 kJ/mol), indicating the action of a similar mechanism for the effect of temperature on oxygen consumption. © 1999 John Wiley & Sons, Inc. Biotechnol Bioeng 64: 349–356, 1999.


  • Real-time monitoring and control of glucose and lactate concentrations in a mammalian cell perfusion reactor

    by S. S. Ozturk, J. C. Thrift, J. D. Blackie, D. Naveh

    On-line monitoring and control of cell culture fermentation is important for optimal and consistent production of biologicals. In this work, glucose and lactate concentrations are monitored on-line using a commercially available analyzer (Model 2700, Yellow Springs Instruments, Yellow Springs, OH) during batch and perfusion hybridoma cell fermentation. Cell free samples from the reactor are obtained using a 0.45 μm hollow fiber filtering system placed in a circulation loop. The samples were analyzed at specified times and the data are collected on a computer. A process control strategy was developed to control the concentrations of glucose and lactate in a perfusion reactor where the feed rate is adjusted to maintain their concentrations at desired set points. Hybridoma cells (A10G10) were cultivated in a high density perfusion culture where cell density increased from 2 to 14 million cells/mL. During this period the control algorithm successfully adjusted the perfusion rate while maintaining constant glucose and lactate concentrations. Glucose consumption and lactate accumulation rates as well as net lactate yield on glucose were monitored continuously during perfusion culture. These metabolic rates were observed to be independent of cell concentration and were used for the estimation of viable cell density in the reactor. © 1997 John Wiley & Sons, Inc. Biotechnol Bioeng 53: 372–378, 1997.