Walter C. Renberg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Walter C. Renberg has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
L. J. Armbrust
Department of Clinical Sciences, Kansas State University, College of Veterinary Medicine, Manhattan, KS, USA
1 shared publicationM. G. Radlinsky
Department of Clinical Sciences, Kansas State University, Manhattan, KS, USA
1 shared publication
Latest Publications
- 1 January 2004
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 17 (01) , 25-29
Comparison of the standing tangential radiographic projection of the hip with standard methods of evaluation for hip dysplasia in the dog
Summary: The standing tangential radiographic position (STRP) of the hip is a technique that enables the clinician to visualize the femoral head and acetabulum in an unsedated patient in a weight-bearing stance. This study compared the technique to other radiographic methods of evaluating canine hips for the dysplasia. The methods were compared as to Norberg angle, Distraction Index and by use of novel measures of subluxation and coverage. A statistical significance of correlation was not seen between the STRP technique and other methods. Although a variety of explanations are discussed, the authors do not recommend the use of this technique for the evaluation of hip dysplasia.
- 1 January 2004
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 17 (01) , 25-29
Comparison of the standing tangential radiographic projection of the hip with standard methods of evaluation for hip dysplasia in the dog
Summary: The standing tangential radiographic position (STRP) of the hip is a technique that enables the clinician to visualize the femoral head and acetabulum in an unsedated patient in a weight-bearing stance. This study compared the technique to other radiographic methods of evaluating canine hips for the dysplasia. The methods were compared as to Norberg angle, Distraction Index and by use of novel measures of subluxation and coverage. A statistical significance of correlation was not seen between the STRP technique and other methods. Although a variety of explanations are discussed, the authors do not recommend the use of this technique for the evaluation of hip dysplasia.
- 13 January 2001
- Published by Elsevier in Veterinary Clinics of North America: Small Animal Practice
- Vol. 31 (1) , 1-16
Evaluation of the Lame Patient
- 13 January 2001
- Published by Elsevier in Veterinary Clinics of North America: Small Animal Practice
- Vol. 31 (1) , 1-16
Evaluation of the Lame Patient
- 1 January 2001
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 14 (01) , 15-18
In vitro comparison of the locking loop and continuous cruciate suture patterns
Summary: This study was undertaken to test anew suture pattern. Tenorrhaphy wasperformed on 23 pairs of canine deepgluteal tendons. One tendon in eachpair was repaired using a locking loopsuture pattern while the other wasrepaired using a novel continuouscruciate pattern. The tendons weredistracted in a mechanical testing apparatusat a rate of 50 cm/min. Strength atfailure, energy absorbed at failure, andmode of failure were recorded andcompared. The continuous cruciatepattern was stronger at failure andabsorbed greater energy at failure thanthe locking loop pattern. This studyindicated that the continuous cruciatepattern can be used clinically with theknowledge that its strength characteristicsexceed those of the locking looppattern.A new suture pattern was tested in deep gluteal tendons from cadaver dogs. The continuous cruciate suture pattern was found to be significantly stronger than the locking loop pattern in maximum strength and energy absorbed at failure in canine deep gluteal tendons.
- 1 January 2001
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 14 (01) , 15-18
In vitro comparison of the locking loop and continuous cruciate suture patterns
Summary: This study was undertaken to test anew suture pattern. Tenorrhaphy wasperformed on 23 pairs of canine deepgluteal tendons. One tendon in eachpair was repaired using a locking loopsuture pattern while the other wasrepaired using a novel continuouscruciate pattern. The tendons weredistracted in a mechanical testing apparatusat a rate of 50 cm/min. Strength atfailure, energy absorbed at failure, andmode of failure were recorded andcompared. The continuous cruciatepattern was stronger at failure andabsorbed greater energy at failure thanthe locking loop pattern. This studyindicated that the continuous cruciatepattern can be used clinically with theknowledge that its strength characteristicsexceed those of the locking looppattern.A new suture pattern was tested in deep gluteal tendons from cadaver dogs. The continuous cruciate suture pattern was found to be significantly stronger than the locking loop pattern in maximum strength and energy absorbed at failure in canine deep gluteal tendons.