Pei Zhong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Pei Zhong has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Yufeng Zhou
State Key Laboratory of Ultrasound in Medicine and Engineering, Chongqing Medical University, Chongqing 400016, China
2 shared publications F. Yang
Donghua University, Shanghai, China
1 shared publicationH. Y. Zhang
Donghua University, Shanghai, China
1 shared publicationH. Y. Zhou
Donghua University, Shanghai, China
1 shared publicationM. Jiang
Donghua University, Shanghai, China
1 shared publicationSonglin Zhu
1 shared publication
Latest Publications
- 1 June 2017
- Published by Optica Publishing Group in Journal of Optical Technology
- Vol. 84 (6) , 395
Influence of piezoelectric transducer displacement error on defect detection in digital shearography speckle pattern interferometry
This paper focuses on the influence of piezoelectric transducer displacement error on the detection ability of digital shearography speckle pattern interferometry. The established model is based on the principle of shearography using ANSYS and MATLAB software. The simulation uses a circular thin aluminum plate with pressure exerted in the center as a model. The simulation conclusions show that when the loading intensity is large, the defect size is big, the defect location is near to the surface and close to loading, and the influence of piezoelectric transducer displacement error on defect detection is weak. Defects can be detected easily. Otherwise, the influence is great, which may hardly detect the defect. To the best of our knowledge, this is the first published paper focusing on the influence of piezoelectric transducer displacement error on the detection ability of digital shearography speckle pattern interferometry. The conclusions can provide some useful guidance to the actual experiment.
- 1 June 2017
- Published by Optica Publishing Group in Journal of Optical Technology
- Vol. 84 (6) , 395
Influence of piezoelectric transducer displacement error on defect detection in digital shearography speckle pattern interferometry
This paper focuses on the influence of piezoelectric transducer displacement error on the detection ability of digital shearography speckle pattern interferometry. The established model is based on the principle of shearography using ANSYS and MATLAB software. The simulation uses a circular thin aluminum plate with pressure exerted in the center as a model. The simulation conclusions show that when the loading intensity is large, the defect size is big, the defect location is near to the surface and close to loading, and the influence of piezoelectric transducer displacement error on defect detection is weak. Defects can be detected easily. Otherwise, the influence is great, which may hardly detect the defect. To the best of our knowledge, this is the first published paper focusing on the influence of piezoelectric transducer displacement error on the detection ability of digital shearography speckle pattern interferometry. The conclusions can provide some useful guidance to the actual experiment.
- 1 December 2001
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 110 (6) , 3283-3291
Suppression of large intraluminal bubble expansion in shock wave lithotripsy without compromising stone comminution: Methodology and in vitro experiments
To reduce the potential of vascular injury without compromising the stone comminution capability of a Dornier HM-3 lithotripter, we have devised a method to suppress intraluminal bubble expansion via in situ pulse superposition. A thin shell ellipsoidal reflector insert was designed and fabricated to fit snugly into the original reflector of an HM-3 lithotripter. The inner surface of the reflector insert shares the same first focus with the original HM-3 reflector, but has its second focus located 5 mm proximal to the generator than that of the HM-3 reflector. With this modification, the original lithotripter shock wave is partitioned into a leading lithotripter pulse (peak positive pressure of 46 MPa and positive pulse duration of 1 μs at 24 kV) and an ensuing second compressive wave of 10 MPa peak pressure and 2 μs pulse duration, separated from each other by about 4 μs. Superposition of the two waves leads to a selective truncation of the trailing tensile component of the lithotripter shock wave, and consequently, a reduction in the maximum bubble expansion up to 41% compared to that produced by the original reflector. The pulse amplitude and −6 dB beam width of the leading lithotripter shock wave from the upgraded reflector at 24 kV are comparable to that produced by the original HM-3 reflector at 20 kV. At the lithotripter focus, while only about 30 shocks are needed to cause a rupture of a blood vessel phantom made of cellulose hollow fiber (i.d.=0.2 mm) using the original HM-3 reflector at 20 kV, no rupture could be produced after 200 shocks using the upgraded reflector at 24 kV. On the other hand, after 100 shocks the upgraded reflector at 24 kV can achieve a stone comminution efficiency of 22%, which is better than the 18% efficiency produced by the original reflector at 20 kV All together, it has been shown in vitro that the upgraded reflector can produce satisfactory stone comminution while significantly reducing the potential for vessel rupture in shock wave lithotripsy.- 1 December 2001
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 110 (6) , 3283-3291
Suppression of large intraluminal bubble expansion in shock wave lithotripsy without compromising stone comminution: Methodology and in vitro experiments
To reduce the potential of vascular injury without compromising the stone comminution capability of a Dornier HM-3 lithotripter, we have devised a method to suppress intraluminal bubble expansion via in situ pulse superposition. A thin shell ellipsoidal reflector insert was designed and fabricated to fit snugly into the original reflector of an HM-3 lithotripter. The inner surface of the reflector insert shares the same first focus with the original HM-3 reflector, but has its second focus located 5 mm proximal to the generator than that of the HM-3 reflector. With this modification, the original lithotripter shock wave is partitioned into a leading lithotripter pulse (peak positive pressure of 46 MPa and positive pulse duration of 1 μs at 24 kV) and an ensuing second compressive wave of 10 MPa peak pressure and 2 μs pulse duration, separated from each other by about 4 μs. Superposition of the two waves leads to a selective truncation of the trailing tensile component of the lithotripter shock wave, and consequently, a reduction in the maximum bubble expansion up to 41% compared to that produced by the original reflector. The pulse amplitude and −6 dB beam width of the leading lithotripter shock wave from the upgraded reflector at 24 kV are comparable to that produced by the original HM-3 reflector at 20 kV. At the lithotripter focus, while only about 30 shocks are needed to cause a rupture of a blood vessel phantom made of cellulose hollow fiber (i.d.=0.2 mm) using the original HM-3 reflector at 20 kV, no rupture could be produced after 200 shocks using the upgraded reflector at 24 kV. On the other hand, after 100 shocks the upgraded reflector at 24 kV can achieve a stone comminution efficiency of 22%, which is better than the 18% efficiency produced by the original reflector at 20 kV All together, it has been shown in vitro that the upgraded reflector can produce satisfactory stone comminution while significantly reducing the potential for vessel rupture in shock wave lithotripsy.- 1 January 2001
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 27 (1) , 119-134
Dynamics of bubble oscillation in constrained media and mechanisms of vessel rupture in swl
- 1 January 2001
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 27 (1) , 119-134
Dynamics of bubble oscillation in constrained media and mechanisms of vessel rupture in swl