Atsuo Tomidokoro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Atsuo Tomidokoro has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Tetsuro Oshika
2 shared publications- Tetsuro Oshika
Department of Ophthalmology, University of Tokyo School of Medicine, Tokyo, Japan
2 shared publications K Maruo
1 shared publicationKoichiro Eguchi
1 shared publicationN Miyata
1 shared publicationShiro Amano
1 shared publication
Latest Publications
- 1 December 2001
- Published by Elsevier in Ophthalmology
- Vol. 108 (12) , 2209-2212
Corneal irregular astigmatism and contrast sensitivity after photorefractive keratectomy
- 1 December 2001
- Published by Elsevier in Ophthalmology
- Vol. 108 (12) , 2209-2212
Corneal irregular astigmatism and contrast sensitivity after photorefractive keratectomy
- 1 July 1999
- Published by Wolters Kluwer Health in Cornea
- Vol. 18 (4) , 412-415
Quantitative Analysis of Regular and Irregular Astigmatism Induced by Pterygium
To quantitatively evaluate the influence of pterygium and its removal surgery on both regular and irregular corneal astigmatism. In 19 eyes of 19 patients undergoing pterygium surgery, videokeratographic measurements were taken before and 1 month after surgery. Using Fourier harmonic analysis, dioptric data on mire rings were decomposed into spherical, regular astigmatism, and irregular astigmatism (decentration and higher order irregularity) components. The distance between the line of sight and the advancing edge of pterygium was measured, and the eyes were classified into two groups: large pterygium group (the distance <2.0 mm, n = 7) and small pterygium group (≥2.0 mm, n = 12). Fifteen eyes of 15 subjects served as age-matched normal control eyes. Before surgery, the magnitudes of regular astigmatism and higher order irregular astigmatism showed significant correlation with the size of pterygium. Regular astigmatism, asymmetry, and higher order irregularity in the large pterygium group were significantly greater than those of normal control eyes. The pterygium removal surgery significantly improved these changes, but regular astigmatism and higher order irregularity in the large pterygium group still remained significantly greater than those in the normal control eyes. Pterygium induces a significant amount of regular and irregular astigmatism in proportion to its size. The removal surgery can improve these changes, but corneal distortion does not normalize completely in eyes with advanced pterygium.
- 1 July 1999
- Published by Wolters Kluwer Health in Cornea
- Vol. 18 (4) , 412-415
Quantitative Analysis of Regular and Irregular Astigmatism Induced by Pterygium
To quantitatively evaluate the influence of pterygium and its removal surgery on both regular and irregular corneal astigmatism. In 19 eyes of 19 patients undergoing pterygium surgery, videokeratographic measurements were taken before and 1 month after surgery. Using Fourier harmonic analysis, dioptric data on mire rings were decomposed into spherical, regular astigmatism, and irregular astigmatism (decentration and higher order irregularity) components. The distance between the line of sight and the advancing edge of pterygium was measured, and the eyes were classified into two groups: large pterygium group (the distance <2.0 mm, n = 7) and small pterygium group (≥2.0 mm, n = 12). Fifteen eyes of 15 subjects served as age-matched normal control eyes. Before surgery, the magnitudes of regular astigmatism and higher order irregular astigmatism showed significant correlation with the size of pterygium. Regular astigmatism, asymmetry, and higher order irregularity in the large pterygium group were significantly greater than those of normal control eyes. The pterygium removal surgery significantly improved these changes, but regular astigmatism and higher order irregularity in the large pterygium group still remained significantly greater than those in the normal control eyes. Pterygium induces a significant amount of regular and irregular astigmatism in proportion to its size. The removal surgery can improve these changes, but corneal distortion does not normalize completely in eyes with advanced pterygium.
- 1 September 1998
- Published by Wolters Kluwer Health in Cornea
- Vol. 17 (5) , 517-521
Corneal Astigmatism After Scleral Buckling Surgery Assessed by Fourier Analysis of Videokeratography Data
To evaluate quantitatively the changes in corneal curvature, including irregular astigmatism, after scleral buckling surgery for retinal detachment. In 29 eyes of 29 patients undergoing scleral explant surgery, videokeratographic measurements were carried out before and 1 week, 1 month, and 3 months after surgery. Using Fourier harmonic analysis, dioptric data on mire rings were decomposed into spherical, regular astigmatic, and irregular astigmatic (decentration and higher order irregularity) components. The irregular astigmatic component significantly increased at 1 week post-operatively but returned to the preoperative level 1 month after surgery. The regular astigmatism also displayed a transient increase up to 1 month after surgery. The increases in regular astigmatism were significant in eyes that had scleral buckling of ≤180° but not in eyes with buckles extending >180°. Changes in irregular astigmatism after retinal detachment surgery were quantitatively evaluated. The scleral buckling surgery causes a transient increase in irregular astigmatism as well as regular astigmatism.
- 1 September 1998
- Published by Wolters Kluwer Health in Cornea
- Vol. 17 (5) , 517-521
Corneal Astigmatism After Scleral Buckling Surgery Assessed by Fourier Analysis of Videokeratography Data
To evaluate quantitatively the changes in corneal curvature, including irregular astigmatism, after scleral buckling surgery for retinal detachment. In 29 eyes of 29 patients undergoing scleral explant surgery, videokeratographic measurements were carried out before and 1 week, 1 month, and 3 months after surgery. Using Fourier harmonic analysis, dioptric data on mire rings were decomposed into spherical, regular astigmatic, and irregular astigmatic (decentration and higher order irregularity) components. The irregular astigmatic component significantly increased at 1 week post-operatively but returned to the preoperative level 1 month after surgery. The regular astigmatism also displayed a transient increase up to 1 month after surgery. The increases in regular astigmatism were significant in eyes that had scleral buckling of ≤180° but not in eyes with buckles extending >180°. Changes in irregular astigmatism after retinal detachment surgery were quantitatively evaluated. The scleral buckling surgery causes a transient increase in irregular astigmatism as well as regular astigmatism.
- 1 April 1998
- Vol. 39 (5) , 705-9
Quantitative evaluation of irregular astigmatism by fourier series harmonic analysis of videokeratography data.
To assess quantitatively corneal irregular astigmatism in association with best spectacle-corrected visual acuity. Refractive powers on a mire ring measured with computerized videokeratography were decomposed, using the Fourier series harmonic analysis. Extracting spherical and regular astigmatic components, the remaining irregular astigmatic component was quantified on rings 2 through 9. A weighted average was calculated by using the Stiles-Crawford effect on the basis of the radius of each ring of each eye and was used as an index of the irregular astigmatic component. Data analyses were carried out in 108 eyes, including 53 normal eyes, 34 eyes with keratoconus, and 21 eyes that had undergone penetrating keratoplasty for keratoconus. Keratoconic eyes and eyes after keratoplasty were included in the study only if visual acuity, corrected with a hard contact lens, was 20/20 or better. Logarithm of best spectacle-corrected visual acuity, age, type of disease, refractive astigmatism, irregular astigmatic component, surface regularity index, and surface asymmetry index were analyzed. In results of multiple regression analysis, the irregular astigmatic component was significantly correlated with best spectacle-corrected visual acuity (r = -0.744; adjusted R2 = 0.549; P < 0.001), whereas other explanatory variables showed no correlation with best spectacle-corrected visual acuity. This model of the irregular astigmatic component seems to be an efficient, quantitative means of describing corneal irregular astigmatism.
- 1 April 1998
- Vol. 39 (5) , 705-9
Quantitative evaluation of irregular astigmatism by fourier series harmonic analysis of videokeratography data.
To assess quantitatively corneal irregular astigmatism in association with best spectacle-corrected visual acuity. Refractive powers on a mire ring measured with computerized videokeratography were decomposed, using the Fourier series harmonic analysis. Extracting spherical and regular astigmatic components, the remaining irregular astigmatic component was quantified on rings 2 through 9. A weighted average was calculated by using the Stiles-Crawford effect on the basis of the radius of each ring of each eye and was used as an index of the irregular astigmatic component. Data analyses were carried out in 108 eyes, including 53 normal eyes, 34 eyes with keratoconus, and 21 eyes that had undergone penetrating keratoplasty for keratoconus. Keratoconic eyes and eyes after keratoplasty were included in the study only if visual acuity, corrected with a hard contact lens, was 20/20 or better. Logarithm of best spectacle-corrected visual acuity, age, type of disease, refractive astigmatism, irregular astigmatic component, surface regularity index, and surface asymmetry index were analyzed. In results of multiple regression analysis, the irregular astigmatic component was significantly correlated with best spectacle-corrected visual acuity (r = -0.744; adjusted R2 = 0.549; P < 0.001), whereas other explanatory variables showed no correlation with best spectacle-corrected visual acuity. This model of the irregular astigmatic component seems to be an efficient, quantitative means of describing corneal irregular astigmatism.
- 1 March 1995
- Vol. 99 (3) , 296-301
[Quantitative evaluation of corneal irregular astigmatism using computed corneal topography].
A new method was developed to quantify corneal irregular astigmatism using computed corneal topography. Refractive powers on a mire ring projected on a toric plane (regular cornea) can be approximated to follow a sine curve. The discrepancy between the approximated sine curve and actual refractive powers was calculated and employed as a parameter of corneal irregular astigmatism. Artificial precision models of a sphere and a toric plane showed similar parameters and the least amount of irregular astigmatism (0.02-0.05D). Consecutive measurements on normal human corneas displayed a reproducible irregular astigmatism range of 0.10-0.25D. Irregular astigatism of the eyes with pterygium was significantly greater than that of normal human controls even from early stages of the disease. Surgery for removal of the pterygium normalized the amount of regular astigmatism regardless of the size of the pterygium, but irregular astigmatism of the eyes with large pterygium (the apex reaching within the central 2 mm cornea) remained at a significantly higher than normal level. It was concluded that the current method enables a quantitative analysis of corneal irregular astigmatism, independent by the amount of regular antigmatism.
- 1 March 1995
- Vol. 99 (3) , 296-301
[Quantitative evaluation of corneal irregular astigmatism using computed corneal topography].
A new method was developed to quantify corneal irregular astigmatism using computed corneal topography. Refractive powers on a mire ring projected on a toric plane (regular cornea) can be approximated to follow a sine curve. The discrepancy between the approximated sine curve and actual refractive powers was calculated and employed as a parameter of corneal irregular astigmatism. Artificial precision models of a sphere and a toric plane showed similar parameters and the least amount of irregular astigmatism (0.02-0.05D). Consecutive measurements on normal human corneas displayed a reproducible irregular astigmatism range of 0.10-0.25D. Irregular astigatism of the eyes with pterygium was significantly greater than that of normal human controls even from early stages of the disease. Surgery for removal of the pterygium normalized the amount of regular astigmatism regardless of the size of the pterygium, but irregular astigmatism of the eyes with large pterygium (the apex reaching within the central 2 mm cornea) remained at a significantly higher than normal level. It was concluded that the current method enables a quantitative analysis of corneal irregular astigmatism, independent by the amount of regular antigmatism.