Jen-Fon Jen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jen-Fon Jen has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Vinoth Kumar Ponnusamy
Department of Medicinal and Applied Chemistry, Kaohsiung Medical University, Kaohsiung City, Taiwan
10 shared publications Abilasha Ramkumar
Department of Chemistry, National Chung Hsing University, Taichung 402, Taiwan
3 shared publicationsCheing-Tong Yan
Department of Occupational Safety and Health and Department of Medical Research, Chung-Shan Medical University, Taichung 402, Taiwan
3 shared publicationsChiao-Wen Lin
Department of Chemistry, National Chung-Hsing University, Taichung 402, Taiwan
2 shared publicationsChiu-Hwa Lin
National Chung Hsing University
2 shared publicationsChun-Tan Chang
National Chung-Hsing University
2 shared publications
Latest Publications
- 1 August 2018
- Published by Elsevier in Journal of Chromatography A
- Vol. 1564, 51-58
A sublimate sorbent for stir-bar sorptive extraction of aqueous endocrine disruptor pesticides for gas chromatography-electron capture detection
- 1 August 2018
- Published by Elsevier in Journal of Chromatography A
- Vol. 1564, 51-58
A sublimate sorbent for stir-bar sorptive extraction of aqueous endocrine disruptor pesticides for gas chromatography-electron capture detection
- 1 January 2015
- Published by Elsevier in Analytica Chimica Acta
- Vol. 854, 70-77
A novel fatty-acid-based in-tube dispersive liquid–liquid microextraction technique for the rapid determination of nonylphenol and 4-tert-octylphenol in aqueous samples using high-performance liquid chromatography–ultraviolet detection
- 1 January 2015
- Published by Elsevier in Analytica Chimica Acta
- Vol. 854, 70-77
A novel fatty-acid-based in-tube dispersive liquid–liquid microextraction technique for the rapid determination of nonylphenol and 4-tert-octylphenol in aqueous samples using high-performance liquid chromatography–ultraviolet detection
- 17 May 2013
- Published by Wiley in Journal of Separation Science
- Vol. 36 (14) , 2339-2347
Novel solvent‐free microwave‐assisted extraction coupled with low‐density solvent‐based in‐tube ultrasound‐assisted emulsification microextraction for the fast analysis of organophosphorus pesticides in soils
A novel and rapid solventless microwave‐assisted extraction coupled with low‐density solvent‐based in‐tube ultrasound‐assisted emulsification microextraction has been developed for the efficient determination of nine organophosphorus pesticides in soils by GC analysis with microelectron capture detection. A specially designed, homemade glass tube inbuilt with a scaled capillary tube was used as an extraction device to collect and measure the separated extractant phase easily. Parameters affecting the efficiencies of the developed method were thoroughly investigated. From experimental results, the following conditions were selected for the extraction of organophosphorus pesticides from 1.0 g of soil sample to 5 mL of aqueous solution under 226 W of microwave irradiation for 2.5 min followed by ultrasound‐assisted emulsification microextraction with 20 μL toluene for 30 s and then centrifugation at 3200 rpm for 3 min. Detections were linear in the range of 0.25–10 ng/g with detection limits between 0.04 and 0.13 ng/g for all target analytes. The applicability of the method to real samples was assessed on agricultural contaminated soils and the recoveries ranged between 91.4 and 101.3%. Compared to other methods, the present method was shown to be highly competitive in terms of sensitivity, cost, eco‐friendly nature, and analysis speed.
- 17 May 2013
- Published by Wiley in Journal of Separation Science
- Vol. 36 (14) , 2339-2347
Novel solvent‐free microwave‐assisted extraction coupled with low‐density solvent‐based in‐tube ultrasound‐assisted emulsification microextraction for the fast analysis of organophosphorus pesticides in soils
A novel and rapid solventless microwave‐assisted extraction coupled with low‐density solvent‐based in‐tube ultrasound‐assisted emulsification microextraction has been developed for the efficient determination of nine organophosphorus pesticides in soils by GC analysis with microelectron capture detection. A specially designed, homemade glass tube inbuilt with a scaled capillary tube was used as an extraction device to collect and measure the separated extractant phase easily. Parameters affecting the efficiencies of the developed method were thoroughly investigated. From experimental results, the following conditions were selected for the extraction of organophosphorus pesticides from 1.0 g of soil sample to 5 mL of aqueous solution under 226 W of microwave irradiation for 2.5 min followed by ultrasound‐assisted emulsification microextraction with 20 μL toluene for 30 s and then centrifugation at 3200 rpm for 3 min. Detections were linear in the range of 0.25–10 ng/g with detection limits between 0.04 and 0.13 ng/g for all target analytes. The applicability of the method to real samples was assessed on agricultural contaminated soils and the recoveries ranged between 91.4 and 101.3%. Compared to other methods, the present method was shown to be highly competitive in terms of sensitivity, cost, eco‐friendly nature, and analysis speed.
- 15 March 2013
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (10) , 2572-2577
Rapid determination of indapamide in human urine using novel low-density solvent based ultrasound assisted emulsification microextraction coupled with high performance liquid chromatography-variable wavelength detection
Indapamide belongs to the class of thiazide-type diuretic drugs and is widely used in the treatment of hypertension and nephrolithiasis. In this work, a simple, rapid and efficient low density solvent (LDS) based ultrasound assisted emulsification microextraction (USAEME) method combined with high performance liquid chromatography-variable wavelength detection (HPLC-VWD) was investigated for the determination of a popular drug of abuse, indapamide, in human urine samples. The target compound was extracted from acidified sample solution with a few microliter amount of LDS by a USAEME method. The influence of several important experimental variables such as selection of the extraction solvent and its volume, ultrasonication time, pH and ionic strength were thoroughly examined and optimized. Under optimal conditions, the calibration was linear in concentration range from 1–100 ng mL−1 with a correlation coefficient of 0.9977 for the target analyte. The limit of detection based on signal to noise ratio of 3 was 0.3 ng mL−1 and the relative standard deviations varied from 1.2–6.6%. The proposed method provides a rapid, sensitive, low cost, easy to handle, and convenient procedure to determine indapamide in human urine samples.
- 15 March 2013
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (10) , 2572-2577
Rapid determination of indapamide in human urine using novel low-density solvent based ultrasound assisted emulsification microextraction coupled with high performance liquid chromatography-variable wavelength detection
Indapamide belongs to the class of thiazide-type diuretic drugs and is widely used in the treatment of hypertension and nephrolithiasis. In this work, a simple, rapid and efficient low density solvent (LDS) based ultrasound assisted emulsification microextraction (USAEME) method combined with high performance liquid chromatography-variable wavelength detection (HPLC-VWD) was investigated for the determination of a popular drug of abuse, indapamide, in human urine samples. The target compound was extracted from acidified sample solution with a few microliter amount of LDS by a USAEME method. The influence of several important experimental variables such as selection of the extraction solvent and its volume, ultrasonication time, pH and ionic strength were thoroughly examined and optimized. Under optimal conditions, the calibration was linear in concentration range from 1–100 ng mL−1 with a correlation coefficient of 0.9977 for the target analyte. The limit of detection based on signal to noise ratio of 3 was 0.3 ng mL−1 and the relative standard deviations varied from 1.2–6.6%. The proposed method provides a rapid, sensitive, low cost, easy to handle, and convenient procedure to determine indapamide in human urine samples.
- 14 March 2013
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (9) , 2352-2359
Rapid analysis of triclosan in water samples using an in-tube ultrasonication assisted emulsification microextraction coupled with gas chromatography-electron capture detection
In this study, a new in-tube based ultrasound-assisted emulsification microextraction (IT-USAEME) technique coupled with gas chromatography-micro-electron capture detection (GC-μECD) was developed for the efficient and rapid analysis of triclosan in environmental water samples. In this extraction procedure, the aqueous sample was taken in an indigenously fabricated home-made glass extraction device (an 8 mL glass tube inbuilt with a self-scaled capillary tip) and extraction solvent (low density organic solvent) was added to it followed by ultrasonication. After extraction, the upper extractant layer was narrowed into the self-scaled capillary tip by pushing the plunger plug; thus making the collection and measurement of the upper organic solvent layer simple and convenient. Parameters affecting the extraction efficiency such as selection of extraction solvent, extraction solvent volume, ultrasonication time, pH and ionic strength were thoroughly investigated and optimized. Under optimal conditions, the method showed good linearity in the concentration range from 20–2000 ng L−1 with a correlation coefficient of 0.9982 for the target analyte. The limit of detection was 4 ng L−1 and the enrichment factor obtained was 331. The method was validated with real water samples and the relative recoveries of environmental water samples ranged between 91.2 and 97.3% and relative standard deviations ranged between 2.8 and 5.4%, making the proposed method highly reliable. Moreover, the present approach avoids the usage of chlorinated organic extraction solvents and derivatization processes for triclosan determination. The proposed method provides a simple, rapid, sensitive, low cost, easy to handle (in-tube set-up for USAEME) and eco-friendly procedure to determine triclosan in aqueous samples.
- 14 March 2013
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (9) , 2352-2359
Rapid analysis of triclosan in water samples using an in-tube ultrasonication assisted emulsification microextraction coupled with gas chromatography-electron capture detection
In this study, a new in-tube based ultrasound-assisted emulsification microextraction (IT-USAEME) technique coupled with gas chromatography-micro-electron capture detection (GC-μECD) was developed for the efficient and rapid analysis of triclosan in environmental water samples. In this extraction procedure, the aqueous sample was taken in an indigenously fabricated home-made glass extraction device (an 8 mL glass tube inbuilt with a self-scaled capillary tip) and extraction solvent (low density organic solvent) was added to it followed by ultrasonication. After extraction, the upper extractant layer was narrowed into the self-scaled capillary tip by pushing the plunger plug; thus making the collection and measurement of the upper organic solvent layer simple and convenient. Parameters affecting the extraction efficiency such as selection of extraction solvent, extraction solvent volume, ultrasonication time, pH and ionic strength were thoroughly investigated and optimized. Under optimal conditions, the method showed good linearity in the concentration range from 20–2000 ng L−1 with a correlation coefficient of 0.9982 for the target analyte. The limit of detection was 4 ng L−1 and the enrichment factor obtained was 331. The method was validated with real water samples and the relative recoveries of environmental water samples ranged between 91.2 and 97.3% and relative standard deviations ranged between 2.8 and 5.4%, making the proposed method highly reliable. Moreover, the present approach avoids the usage of chlorinated organic extraction solvents and derivatization processes for triclosan determination. The proposed method provides a simple, rapid, sensitive, low cost, easy to handle (in-tube set-up for USAEME) and eco-friendly procedure to determine triclosan in aqueous samples.
- 7 December 2012
- Published by Springer Nature in Chromatographia
- Vol. 76 (1-2) , 75-83
Fast Analysis of Synthetic Pyrethroid Metabolites in Water Samples Using In-Syringe Derivatization Coupled Hollow Fiber Mediated Liquid Phase Microextraction with GC-ECD
- 7 December 2012
- Published by Springer Nature in Chromatographia
- Vol. 76 (1-2) , 75-83
Fast Analysis of Synthetic Pyrethroid Metabolites in Water Samples Using In-Syringe Derivatization Coupled Hollow Fiber Mediated Liquid Phase Microextraction with GC-ECD
- 14 August 2012
- Published by Springer Nature in Microchimica Acta
- Vol. 179 (1-2) , 141-148
Microwave assisted headspace controlled-temperature single drop microextraction for liquid chromatographic determination of chlorophenols in aqueous samples
- 14 August 2012
- Published by Springer Nature in Microchimica Acta
- Vol. 179 (1-2) , 141-148
Microwave assisted headspace controlled-temperature single drop microextraction for liquid chromatographic determination of chlorophenols in aqueous samples