Jens U. Leike
Jens U. Leike has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
A Sachse
Schering AG, PHZE Parenterale AF, Germany
1 shared publicationAndreas Sachse
1 shared publicationG L Rössling
1 shared publicationKarsten Rupp
1 shared publicationS E Wagner
1 shared publicationW Krause
1 shared publication
Latest Publications
- 1 June 2001
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 36 (6) , 303-308
Characterization of Continuously Extruded Iopromide-Carrying Liposomes for Computed Tomography Blood-Pool Imaging
Leike JU, Sachse A, Rupp K. Characterization of continuously extruded iopromide-carrying liposomes for computed tomography blood-pool imaging. Invest Radiol 2001;36:303–308. Contrast-carrying liposomes are potentially useful as computed tomography (CT) blood-pool agents. In the present study, preliminary safety, pharmacokinetics, and the CT imaging behavior of continuously extruded iopromide-carrying liposomes were studied. Iopromide liposomes were prepared by continuous high-pressure extrusion. Cell membrane–damaging characteristics were assessed in vitro in dog erythrocytes. Acute and subchronic toxicity and pharmacokinetics parameters were determined in rats. Computed tomography imaging efficiency was studied in rabbits. The iopromide-carrying liposomes caused only minor morphological changes in dog erythrocytes. The median lethal dose in rats was approximately 4.5 g of total iodine per kilogram of body weight. In a subchronic tolerance study in rats that were administered six doses of 1 g iodine per kilogram twice a week, no adverse effects were observed. The pharmacokinetics in rats was dose dependent, and elimination of iopromide was almost complete within 7 days after intravenous administration. In rabbits, at a dose of 300 mg total iodine per kilogram, the iopromide-carrying liposomes displayed prolonged blood circulation, with mean CT density differences >60 Hounsfield units (aorta) for up to 10 minutes. The iopromide liposomes were well tolerated, almost completely excreted, and have potential as a CT blood-pool imaging agent.
- 1 June 2001
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 36 (6) , 303-308
Characterization of Continuously Extruded Iopromide-Carrying Liposomes for Computed Tomography Blood-Pool Imaging
Leike JU, Sachse A, Rupp K. Characterization of continuously extruded iopromide-carrying liposomes for computed tomography blood-pool imaging. Invest Radiol 2001;36:303–308. Contrast-carrying liposomes are potentially useful as computed tomography (CT) blood-pool agents. In the present study, preliminary safety, pharmacokinetics, and the CT imaging behavior of continuously extruded iopromide-carrying liposomes were studied. Iopromide liposomes were prepared by continuous high-pressure extrusion. Cell membrane–damaging characteristics were assessed in vitro in dog erythrocytes. Acute and subchronic toxicity and pharmacokinetics parameters were determined in rats. Computed tomography imaging efficiency was studied in rabbits. The iopromide-carrying liposomes caused only minor morphological changes in dog erythrocytes. The median lethal dose in rats was approximately 4.5 g of total iodine per kilogram of body weight. In a subchronic tolerance study in rats that were administered six doses of 1 g iodine per kilogram twice a week, no adverse effects were observed. The pharmacokinetics in rats was dose dependent, and elimination of iopromide was almost complete within 7 days after intravenous administration. In rabbits, at a dose of 300 mg total iodine per kilogram, the iopromide-carrying liposomes displayed prolonged blood circulation, with mean CT density differences >60 Hounsfield units (aorta) for up to 10 minutes. The iopromide liposomes were well tolerated, almost completely excreted, and have potential as a CT blood-pool imaging agent.
- 1 September 1993
- Vol. 28 (9) , 838-44
Preparation and evaluation of lyophilized iopromide-carrying liposomes for liver tumor detection.
The objective of the present investigation was to demonstrate a new method for the production of iopromide-carrying liposomes. We studied biodistribution and elimination behavior, as well as the computed tomography (CT) liver imaging properties. Iopromide-containing liposomes were prepared by the ethanol evaporation method and subsequently lyophilized. The resuspended liposomes were tested in rats and rabbits. After resuspension, liposomes with a mean diameter of 467 +/- 66 nm and an encapsulation rate of 41.5 +/- 5.5% were obtained. In rats, a marked accumulation of liposomal iopromide was found in the liver and spleen. In rabbits, complete renal elimination of iopromide within 7 days was demonstrated. At a dose of 150 mg total iodine/kg, a small tumor (< 0.5 cm) could be detected in a VX-2-bearing rabbit. The ethanol evaporation method proved to be suitable for the reproducible large-scale manufacture of iopromide liposomes with high encapsulation. The resuspended liposomes displayed favorable biodistribution, elimination and imaging characteristics.
- 1 September 1993
- Vol. 28 (9) , 838-44
Preparation and evaluation of lyophilized iopromide-carrying liposomes for liver tumor detection.
The objective of the present investigation was to demonstrate a new method for the production of iopromide-carrying liposomes. We studied biodistribution and elimination behavior, as well as the computed tomography (CT) liver imaging properties. Iopromide-containing liposomes were prepared by the ethanol evaporation method and subsequently lyophilized. The resuspended liposomes were tested in rats and rabbits. After resuspension, liposomes with a mean diameter of 467 +/- 66 nm and an encapsulation rate of 41.5 +/- 5.5% were obtained. In rats, a marked accumulation of liposomal iopromide was found in the liver and spleen. In rabbits, complete renal elimination of iopromide within 7 days was demonstrated. At a dose of 150 mg total iodine/kg, a small tumor (< 0.5 cm) could be detected in a VX-2-bearing rabbit. The ethanol evaporation method proved to be suitable for the reproducible large-scale manufacture of iopromide liposomes with high encapsulation. The resuspended liposomes displayed favorable biodistribution, elimination and imaging characteristics.