T Salgarello
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
T Salgarello has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
A Colotto
Institute of Ophthalmology, Catholic University, Rome
5 shared publications- Benedetto Falsini
Faculty of Medicine and Surgery, Università Cattolica del Sacro Cuore, 00168 Rome, Italy
4 shared publications L Scullica
4 shared publicationsG Iarossi
2 shared publications- Luca Buzzonetti
Ophthalmology Unit, Bambino Gesù Children's Hospital, Rome, Italy, Italy
2 shared publications M E Galan
2 shared publications
Latest Publications
- 1 September 2009
- Published by Wiley in Acta Ophthalmologica
- Vol. 87
Choroidal blood flow and retinal ganglion cell function in early glaucoma
- 1 September 2009
- Published by Wiley in Acta Ophthalmologica
- Vol. 87
Choroidal blood flow and retinal ganglion cell function in early glaucoma
- 1 June 2001
- Vol. 42 (7) , 1487-94
Correlation of optic nerve head tomography with visual field sensitivity in papilledema.
To quantify the relationship between optic nerve head tomography and perimetric sensitivity in patients with papilledema. Eight patients with variable degrees of recently diagnosed papilledema associated with idiopathic intracranial hypertension (IIH) were evaluated with confocal scanning laser ophthalmoscopy (CSLO) and automated perimetry. Patients were followed up with serial measurements over a period of 5 to 30 months (mean +/- SD, 17.1 +/- 9), while under medical treatment (acetazolamide). The tomographic parameters, volume above reference (VAR), volume above surface (VAS), effective mean height (EMH), and maximum height in contour (MxHC), were obtained by tomography, either globally or from predefined disc sectors. The perimetric indices, mean deviation (MD) and pattern SD (PSD), were evaluated. The results from patients' right eyes and the individual intereye differences in both tomographic and perimetric parameters, were statistically evaluated by nonparametric correlational (Spearman) and repeated measures (Wilcoxon) analyses. At baseline, all tomographic parameters were negatively correlated with MD in global (r = -0.8) and sectorial (r = -0.6) evaluations. The interocular differences in overall tomographic parameters were correlated with corresponding differences in perimetric MD (r = -0.8) and PSD (r = 0.6). During the follow-up period, volumetric disc parameters decreased (P < 0.02), whereas perimetric MD increased (P = 0.02) at comparable times. In patients with recently diagnosed papilledema, optic nerve head tomographic abnormalities are quantitatively correlated with visual field sensitivity losses. Therapeutic improvement of volumetric parameters may be paralleled by recovery in perimetric sensitivity. The data support the possible use of both techniques in combination to monitor the amount of papilledema and the effectiveness of treatments designed to reduce intracranial hypertension.
- 1 June 2001
- Vol. 42 (7) , 1487-94
Correlation of optic nerve head tomography with visual field sensitivity in papilledema.
To quantify the relationship between optic nerve head tomography and perimetric sensitivity in patients with papilledema. Eight patients with variable degrees of recently diagnosed papilledema associated with idiopathic intracranial hypertension (IIH) were evaluated with confocal scanning laser ophthalmoscopy (CSLO) and automated perimetry. Patients were followed up with serial measurements over a period of 5 to 30 months (mean +/- SD, 17.1 +/- 9), while under medical treatment (acetazolamide). The tomographic parameters, volume above reference (VAR), volume above surface (VAS), effective mean height (EMH), and maximum height in contour (MxHC), were obtained by tomography, either globally or from predefined disc sectors. The perimetric indices, mean deviation (MD) and pattern SD (PSD), were evaluated. The results from patients' right eyes and the individual intereye differences in both tomographic and perimetric parameters, were statistically evaluated by nonparametric correlational (Spearman) and repeated measures (Wilcoxon) analyses. At baseline, all tomographic parameters were negatively correlated with MD in global (r = -0.8) and sectorial (r = -0.6) evaluations. The interocular differences in overall tomographic parameters were correlated with corresponding differences in perimetric MD (r = -0.8) and PSD (r = 0.6). During the follow-up period, volumetric disc parameters decreased (P < 0.02), whereas perimetric MD increased (P = 0.02) at comparable times. In patients with recently diagnosed papilledema, optic nerve head tomographic abnormalities are quantitatively correlated with visual field sensitivity losses. Therapeutic improvement of volumetric parameters may be paralleled by recovery in perimetric sensitivity. The data support the possible use of both techniques in combination to monitor the amount of papilledema and the effectiveness of treatments designed to reduce intracranial hypertension.
- 1 September 2000
- Vol. 41 (10) , 2960-6
Ultrasonographic evaluation of optic disc swelling: comparison with CSLO in idiopathic intracranial hypertension.
To determine the accuracy and reproducibility of ultrasonographic (US) readings of optic disc elevations in patients with papilledema compared with confocal scanning laser ophthalmoscope (CSLO) measurements. One randomly selected eye of 22 patients with idiopathic intracranial hypertension (IIH) and a variable degree of optic disc swelling underwent five and three repeated measurements of disc height using high-resolution ultrasonography (Biovision unit; Quantel Medical, Clermont-Ferrand, France) and CSLO (Heidelberg Retina Tomograph [HRT]; Heidelberg Engineering, Heidelberg, Germany), respectively. The same procedure was assessed in 14 subjects with variable degrees of physiologic optic disc cupping. US and HRT measurements from each group were individually compared with each other to estimate the accuracy of US readings in both disc conditions in comparison with HRT data. Ultrasonographic readings were positively correlated with HRT measurements in both swollen (r = 0.62, P: = 0.002) and excavated disc (r = 0.84, P: < 0.0002). The 95% limits of agreement between the instruments were 0.24 +/- 0.59 mm (mean +/- 2 SD) and 0. 05 +/- 0.3 mm for swelling and cupping measurements, respectively. The coefficient of variation was 7.63% and 1.8% for swelling and 7. 93% and 5.91% for cupping, with US and HRT, respectively. The results indicate that US and CSLO readings are correlated i: both disc swelling and cupping conditions, but to a different extent because of a significant discrepancy in papilledema. US assessment can be considered highly reproducible. Combined US and HRT optic disc analysis may be recommended in papilledema evaluation as long as a better correlation can be demonstrated in further studies.
- 1 September 2000
- Vol. 41 (10) , 2960-6
Ultrasonographic evaluation of optic disc swelling: comparison with CSLO in idiopathic intracranial hypertension.
To determine the accuracy and reproducibility of ultrasonographic (US) readings of optic disc elevations in patients with papilledema compared with confocal scanning laser ophthalmoscope (CSLO) measurements. One randomly selected eye of 22 patients with idiopathic intracranial hypertension (IIH) and a variable degree of optic disc swelling underwent five and three repeated measurements of disc height using high-resolution ultrasonography (Biovision unit; Quantel Medical, Clermont-Ferrand, France) and CSLO (Heidelberg Retina Tomograph [HRT]; Heidelberg Engineering, Heidelberg, Germany), respectively. The same procedure was assessed in 14 subjects with variable degrees of physiologic optic disc cupping. US and HRT measurements from each group were individually compared with each other to estimate the accuracy of US readings in both disc conditions in comparison with HRT data. Ultrasonographic readings were positively correlated with HRT measurements in both swollen (r = 0.62, P: = 0.002) and excavated disc (r = 0.84, P: < 0.0002). The 95% limits of agreement between the instruments were 0.24 +/- 0.59 mm (mean +/- 2 SD) and 0. 05 +/- 0.3 mm for swelling and cupping measurements, respectively. The coefficient of variation was 7.63% and 1.8% for swelling and 7. 93% and 5.91% for cupping, with US and HRT, respectively. The results indicate that US and CSLO readings are correlated i: both disc swelling and cupping conditions, but to a different extent because of a significant discrepancy in papilledema. US assessment can be considered highly reproducible. Combined US and HRT optic disc analysis may be recommended in papilledema evaluation as long as a better correlation can be demonstrated in further studies.
- 1 July 2000
- Vol. 41 (8) , 2205-11
Photopic negative response of the human ERG: losses associated with glaucomatous damage.
To evaluate in glaucomatous eyes the photopic electroretinogram (ERG) negative response (PhNR), a component that follows the b-wave peak and is thought to be correlated with inner retinal activity. Eleven patients with open-angle glaucoma (OAG) and moderate field loss (Humphrey 30-2 [Humphrey Instruments, San Leandro, CA] mean deviation < or = -6 dB), eight with ocular hypertension (OHT), and eight age-matched normal subjects were tested. Optic discs of patients and control subjects were evaluated by confocal scanning laser ophthalmoscopy. ERGs were recorded to long-duration stimuli (250 msec) of photopic luminance (78 candelas [cd] /m2), presented in the macular region (12 degrees x 12 degrees field size) on a steady, adapting background. Amplitudes of the a-wave and b-wave and the PhNR were measured. Pattern reversal ERGs to 30-minute checkerboards were also recorded from patients and control subjects. Compared with control subjects, patients with OAG showed reduced PhNR (average reduction: 62%, P < 0.01), but normal a- and b-wave amplitudes. In patients with OHT, PhNR and a- and b-wave amplitudes did not differ from control values. In individual patients with OAG, PhNR amplitudes were correlated positively with pattern ERG amplitudes (r = 0.80; P < 0.01) and central (12 degrees) perimetric mean deviations (r = 0.68; P < 0.05) and negatively with cup-to-disc area ratios (r = -0.79; P < 0.01) and cup shape measures (r = -0.78; P < 0.01). Similar to that found in monkeys with experimentally induced glaucoma, the PhNR is selectively altered in human glaucoma. The correlation between PhNR losses and clinical parameter abnormalities suggests that this component depends on inner retina integrity and may be of clinical value for detecting glaucomatous damage.
- 1 July 2000
- Vol. 41 (8) , 2205-11
Photopic negative response of the human ERG: losses associated with glaucomatous damage.
To evaluate in glaucomatous eyes the photopic electroretinogram (ERG) negative response (PhNR), a component that follows the b-wave peak and is thought to be correlated with inner retinal activity. Eleven patients with open-angle glaucoma (OAG) and moderate field loss (Humphrey 30-2 [Humphrey Instruments, San Leandro, CA] mean deviation < or = -6 dB), eight with ocular hypertension (OHT), and eight age-matched normal subjects were tested. Optic discs of patients and control subjects were evaluated by confocal scanning laser ophthalmoscopy. ERGs were recorded to long-duration stimuli (250 msec) of photopic luminance (78 candelas [cd] /m2), presented in the macular region (12 degrees x 12 degrees field size) on a steady, adapting background. Amplitudes of the a-wave and b-wave and the PhNR were measured. Pattern reversal ERGs to 30-minute checkerboards were also recorded from patients and control subjects. Compared with control subjects, patients with OAG showed reduced PhNR (average reduction: 62%, P < 0.01), but normal a- and b-wave amplitudes. In patients with OHT, PhNR and a- and b-wave amplitudes did not differ from control values. In individual patients with OAG, PhNR amplitudes were correlated positively with pattern ERG amplitudes (r = 0.80; P < 0.01) and central (12 degrees) perimetric mean deviations (r = 0.68; P < 0.05) and negatively with cup-to-disc area ratios (r = -0.79; P < 0.01) and cup shape measures (r = -0.78; P < 0.01). Similar to that found in monkeys with experimentally induced glaucoma, the PhNR is selectively altered in human glaucoma. The correlation between PhNR losses and clinical parameter abnormalities suggests that this component depends on inner retina integrity and may be of clinical value for detecting glaucomatous damage.
- 1 August 1999
- Vol. 40 (9) , 1989-97
Correlation of pattern electroretinogram with optic disc cup shape in ocular hypertension.
To evaluate the correlation of pattern electroretinogram (PERG), an index of inner retinal function, with confocal scanning laser (CSLO) optic disc structural parameters in ocular hypertension (OHT). Thirty-four patients with OHT, normal white-on-white (Humphrey 30-2) perimetry, and normal clinical optic discs were examined with PERG and CSLO disc analysis. Two groups of normal subjects (n = 38 and 18, for PERG and CSLO, respectively) and a group of 12 patients with early open-angle glaucoma (EOAG) were also tested. Pattern electroretinogram amplitudes were measured in response to sinusoidal gratings of variable spatial frequency (0.58-5.8 cycles/degree), modulated in counter-phase at 7.5 Hz. Morphometric optic disc parameters were obtained by the Heidelberg Retina Tomograph (HRT), either globally or from predefined disc sectors. In addition to standard parameters, the cup shape measure, an index of depth variation and steepness of the cup walls, was determined. In individual OHT patients, PERG amplitudes at 2.6 cycles/degree were negatively correlated with cup shape measures (r = -0.43, P < 0.01) obtained from analysis of the inferotemporal (IT) sector. No significant correlations were found for the other parameters. On average, the cup shape measures derived from IT sector or global analysis were significantly (P < 0.01) worse, and closer to the measures of EOAG patients, in OHT patients with abnormal PERG compared with those with normal PERGs. The cup shape measure displayed a low sensitivity (20%) and a high specificity (100%) in predicting PERG abnormalities in individual OHT patients. The results indicate that in OHT there is a significant although weak correlation between PERG amplitude and the shape of the optic disc cup, suggesting a parallel involvement of both function and morphology. Combined PERG and optic disc cup structural analysis is of potential diagnostic value to detect early damage to optic nerve head in individual OHT patients.
- 1 August 1999
- Vol. 40 (9) , 1989-97
Correlation of pattern electroretinogram with optic disc cup shape in ocular hypertension.
To evaluate the correlation of pattern electroretinogram (PERG), an index of inner retinal function, with confocal scanning laser (CSLO) optic disc structural parameters in ocular hypertension (OHT). Thirty-four patients with OHT, normal white-on-white (Humphrey 30-2) perimetry, and normal clinical optic discs were examined with PERG and CSLO disc analysis. Two groups of normal subjects (n = 38 and 18, for PERG and CSLO, respectively) and a group of 12 patients with early open-angle glaucoma (EOAG) were also tested. Pattern electroretinogram amplitudes were measured in response to sinusoidal gratings of variable spatial frequency (0.58-5.8 cycles/degree), modulated in counter-phase at 7.5 Hz. Morphometric optic disc parameters were obtained by the Heidelberg Retina Tomograph (HRT), either globally or from predefined disc sectors. In addition to standard parameters, the cup shape measure, an index of depth variation and steepness of the cup walls, was determined. In individual OHT patients, PERG amplitudes at 2.6 cycles/degree were negatively correlated with cup shape measures (r = -0.43, P < 0.01) obtained from analysis of the inferotemporal (IT) sector. No significant correlations were found for the other parameters. On average, the cup shape measures derived from IT sector or global analysis were significantly (P < 0.01) worse, and closer to the measures of EOAG patients, in OHT patients with abnormal PERG compared with those with normal PERGs. The cup shape measure displayed a low sensitivity (20%) and a high specificity (100%) in predicting PERG abnormalities in individual OHT patients. The results indicate that in OHT there is a significant although weak correlation between PERG amplitude and the shape of the optic disc cup, suggesting a parallel involvement of both function and morphology. Combined PERG and optic disc cup structural analysis is of potential diagnostic value to detect early damage to optic nerve head in individual OHT patients.
- 1 December 1996
- Vol. 37 (13) , 2663-70
Transiently raised intraocular pressure reveals pattern electroretinogram losses in ocular hypertension.
It is known that the pattern electroretinogram (PERG) of normal subjects is reduced temporarily after short-term elevation of intraocular pressure (IOP). The authors evaluated PERG changes in ocular hypertension during and after transient IOP elevation. Steady state (8 Hz) PERGs to sinusoidal gratings (1.7 cyc/deg spatial frequency) were recorded in seven untreated patients with ocular hypertension at medium risk (maximum IOP, 22 to 25 mm Hg; cup-disk ratio, 0.6 to 0.7; normal Humphrey 30-2 visual field results; positive family history), as well as in six age-matched normal subjects. Recordings were obtained for the baseline condition during a short-term (6-minute) IOP elevation (to 30 mm Hg) by using a suction cup apparatus and during a 6-minute recovery period after removal of the apparatus. During IOP elevation, PERG amplitudes were reduced significantly from baseline values in normal subjects and patients. However, PERG losses were significantly greater in patients (average loss from baseline after 4 minutes of IOP elevation: 72% +/- 7.6%) compared to controls (average loss after 2 minutes of IOP elevation: 40% +/- 7.5%). In the recovery phase, mean PERG amplitude returned to baseline values in normal subjects but not in patients, whose recovery took longer. In normal subjects, PERG phase did not change either during or after IOP elevation. In patients, however, PERG phase showed a delay from baseline during and after IOP elevation (average delay after 6 minutes of recovery: -41.1 degrees +/- 13 degrees). Results indicate that increasing IOP with scleral suction produces greater PERG losses in eyes with ocular hypertension than in normal eyes. This suggests that the inner retina of eyes with ocular hypertension may have a heightened sensitivity to vascular or mechanical changes induced by transient IOP elevation.
- 1 December 1996
- Vol. 37 (13) , 2663-70
Transiently raised intraocular pressure reveals pattern electroretinogram losses in ocular hypertension.
It is known that the pattern electroretinogram (PERG) of normal subjects is reduced temporarily after short-term elevation of intraocular pressure (IOP). The authors evaluated PERG changes in ocular hypertension during and after transient IOP elevation. Steady state (8 Hz) PERGs to sinusoidal gratings (1.7 cyc/deg spatial frequency) were recorded in seven untreated patients with ocular hypertension at medium risk (maximum IOP, 22 to 25 mm Hg; cup-disk ratio, 0.6 to 0.7; normal Humphrey 30-2 visual field results; positive family history), as well as in six age-matched normal subjects. Recordings were obtained for the baseline condition during a short-term (6-minute) IOP elevation (to 30 mm Hg) by using a suction cup apparatus and during a 6-minute recovery period after removal of the apparatus. During IOP elevation, PERG amplitudes were reduced significantly from baseline values in normal subjects and patients. However, PERG losses were significantly greater in patients (average loss from baseline after 4 minutes of IOP elevation: 72% +/- 7.6%) compared to controls (average loss after 2 minutes of IOP elevation: 40% +/- 7.5%). In the recovery phase, mean PERG amplitude returned to baseline values in normal subjects but not in patients, whose recovery took longer. In normal subjects, PERG phase did not change either during or after IOP elevation. In patients, however, PERG phase showed a delay from baseline during and after IOP elevation (average delay after 6 minutes of recovery: -41.1 degrees +/- 13 degrees). Results indicate that increasing IOP with scleral suction produces greater PERG losses in eyes with ocular hypertension than in normal eyes. This suggests that the inner retina of eyes with ocular hypertension may have a heightened sensitivity to vascular or mechanical changes induced by transient IOP elevation.