EMEsther Moreno-Barriuso

Esther Moreno-Barriuso

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Esther Moreno-Barriuso has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 1 May 2001
      • Vol. 42  (6) , 1396-403

    Ocular aberrations before and after myopic corneal refractive surgery: LASIK-induced changes measured with laser ray tracing.

    by E Moreno-Barriuso, J M Lloves, S Marcos, R Navarro, L Llorente, S Barbero

    To determine objectively the changes in the ocular aberrations (3rd order and above) induced by myopic LASIK refractive surgery and its impact on image quality. The ocular aberrations of 22 normal myopic eyes (preoperative refraction ranged from -13 to -2 D) were measured before (2.9 +/- 4.3 weeks) and after (7.7 +/- 3.2 weeks) LASIK refractive surgery using a laser ray tracing technique. A set of laser pencils is sequentially delivered onto the eye through different pupil locations. For each ray, the corresponding retinal image is collected on a CCD camera. The displacement of the image centroid with respect to a reference provides direct information of the ocular aberrations. Root-mean-square (RMS) wavefront error was taken as image quality metric. RMS wavefront error increased significantly in all eyes but two after surgery. On average, LASIK induced a significant (P = 0.0003) 1.9-fold increase in the RMS error for a 6.5-mm pupil. The main contribution was due to the increase (fourfold, P < 0.0001) of spherical aberration. The increase in the RMS for a 3-mm pupil (1.7-fold) was also significant (P = 0.02). The modulation transfer (computed for 6.5-mm pupil) decreased on average by a factor of 2 for middle-high spatial frequencies. (1) Laser ray tracing is a well-suited, robust, and reliable technique for the evaluation of the change of ocular aberrations with refractive surgery. (2) Refractive surgery induces important amounts of 3rd and higher order aberrations. The largest increase occurs for spherical aberration. Decentration of the ablation pattern seems to generate 3rd order aberrations. (3) This result is important for the design of customized ablation algorithms, which should cancel existing preoperative aberrations while avoiding the generation of new aberrations.


  • Comparing Laser Ray Tracing, the Spatially Resolved Refractometer, and the Hartmann-Shack Sensor to Measure the Ocular Wave Aberration

    by Esther Moreno-Barriuso, Susana Marcos, Rafael Navarro, Stephen A. Burns

    To compare quantitatively three techniques to measure the optical aberrations of the human eye: laser ray tracing (LRT), the Hartmann-Shack wavefront sensor (H-S), and the spatially resolved refractometer (SRR). LRT and H-S are objective imaging techniques, whereas SRR is psychophysical. Wave aberrations were measured in two normal subjects with all three techniques implemented in two different laboratories. We compared the experimental variability of the results obtained with each technique with the overall variability across the three methods. For the two subjects measured (RMS wavefront error 0.5 μm and 0.9 μm, respectively), we found a close agreement; the average standard deviation of the Zernike coefficients within a given method was 0.07 μm, whereas the average global standard deviation across techniques was 0.09 μm, which is only slightly higher. There is a close match between the Zernike coefficients obtained by LRT, H-S, and SRR. Thus, all three techniques provide similar information concerning wave aberration when applied to normal human eyes. However, the methods are operationally different, and each has advantages and disadvantages depending on the particular application.


  • Laser Ray Tracing versus Hartmann–Shack sensor for measuring optical aberrations in the human eye

    by Esther Moreno-Barriuso, Rafael Navarro

    A comparison and validation study of Laser Ray Tracing (LRT) and Hartmann–Shack wave-front-sensor (to be referred to as H–S) methods was carried out on both artificial and human eyes. The aim of this work was double. First, we wanted to verify experimentally the equivalence of single- and double-pass measurements for both H–S and LRT. This interest is due to the impossibility of making single-pass measurements in human eyes. In addition, we wanted to validate the LRT technique by comparing it with the H–S wave-front sensor, currently used in many physiological optics laboratories. Comparison of the different methods and configurations carried out in the artificial eye yielded basically the same results in all cases, which means a reciprocal validation of both LRT and H–S, in either single- or double-pass configurations. Other aspects, such as robustness against speckle noise or the influence of the size of the entrance (H–S) or exit (LRT) pupil were studied as well. As a global reference, the point-spread function (PSF) of the artificial eye was recorded directly on a CCD camera and compared with simulated PSF’s computed from the experimental aberration data. We also applied these two methods to real eyes (double pass), finding again a close match between the resulting aberration coefficients and also between the standard errors for two normal subjects. However, for one myopic eye with an especially low optical quality (RMS wave-front error >2 μm) and asymmetric aberrations, the array of spots recorded with the H–S sensor was highly distorted and too difficult to analyze.