HSHellmut von Specht

Hellmut von Specht

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hellmut von Specht has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Linear versus non-linear recordings of transiently-evoked otoacoustic emissions - methodological considerations

    by Hellmut von Specht, Micheal Ganz, Joachim Pethe, Steffen Leuschner, Joseph Pytel

    A non-linear technique is predominantly used for the recording of transiently-evoked otoacoustic emissions (TEOAEs). The aim of this study was to compare linear and non-linear TEOAE recordings. TEOAEs were recorded in 22 normal hearing subjects to clicks from 90 to 30 dB SPL in 10 dB steps with the ILO88 system using both linear and non-linear recording techniques. The non-linear recording technique reduces stimulus artifacts for early latencies, but total elimination could not be proved. Both artifact reduction and significant differences between the two kinds of TEOAE recordings were reduced for longer latencies and lower stimulus intensities. For longer latencies (>10 ms) there was no significant difference between ''linear'' and ''non-linear'' TEOAEs. A higher signal-to-noise ratio was found for ''linear'' TEOAEs, resulting in better identification and a higher test-retest correlation. The linear recording technique, which includes new methods of artifact cancellation in comparison to the mainly utilized non-linear recording technique, should be used especially in hearing screening.


  • Der Einfluß der Reizanstiegszeit und der Hochpaßmaskierung auf die frühen auditorisch evozierten Potentiale

    by D. Bunke, H. von Specht, R. Mühler, J. Pethe, Z. Kevanishvili

    Problems of frequency-specific objective assessment of hearing threshold by means of auditory brainstem response (ABR) have been discussed recently. While a number of workers have recommended methods of selective masking to improve the frequency specificity, others believe that frequency-specific potentials can also be obtained without masking. In this context, the effects of rise-decay time and high-pass masking on ABRs were investigated. ABRs were recorded in normal-hearing subjects and patients with high and low frequency hearing loss by means of surface electrodes between the vertex and the ipsilateral mastoid. The frequency of the stimulus was 1 kHz, and the rise-decay time 1 ms (1-0-1) or 2 ms (2-0-2). High-pass filtered noise (cutoff frequency 1.5 kHz; filter slope 250 dB/octave) was employed for masking. Particular attention was paid to the problem of efficient masking. In normal-hearing subjects under the influence of high-pass masking compared to non-masked ABRs, longer mean latencies and diminished means of the amplitudes of wave V were found, with differences in the near-threshold domain being less pronounced. Similar results were observed in patients with high frequency hearing loss. In patients with low frequency hearing loss, the influence of high-pass masking was especially marked distinctly near to threshold. Furthermore, latency and amplitude differences of wave V of the 1-0-1 and the 2-0-2 stimuli were determined from the ABRs obtained with and without high-pass masking. The differences between the latency differences of both stimuli in the suprathreshold range (70 dB nHL) only were statistically significant. The results are suggestive of an inadequate frequency specificity of unmasked stimuli in the suprathreshold range. Evaluation of the latencies revealed for both rise-decay times a similar frequency specificity near the threshold and a higher frequency specificity of the longer stimulus in the suprathreshold range.


  • Eine optimale Elektrodenposition für die Ableitung auditorisch evozierter Hirnstammpotentiale im Rahmen der Pädaudiologie*

    by J. Pethe, K. Begall, R. Mühler, K. Smukalla, H. von Specht

    Estimation of hearing threshold in children is based on reliable identification of a response to a stimulus in the near-threshold range. It is well known that only wave V can be detected in brainstem potentials evoked by near-threshold stimuli. So the question arises as to whether or not a noncephalic reference electrode compared to the common lateral postition of the reference electrode on the ipsilateral mastoid produces a more stable wave V of increased amplitude. Thirty-three normal hearing children in three age groups (< 6 years, 6-10 years, > 10 years) were investigated. For a near-threshold stimulation with 100-microsecond-clicks (10, 20, 30 dB nHL), bioactivity was simultaneously recorded with the reference electrode in four different locations (ipsilateral mastoid, contralateral mastoid, ipsilateral earlobe, and noncephalic electrode). The noncephalic reference produced the highest absolute and scaled amplitudes. This finding was statistically significant. For all investigated intensities, recording with the noncephalic reference electrode yielded the highest number of reliable detectable potentials. Evaluation of the residual noise in the four recording locations revealed a significantly increased noise level for the noncephalic electrode at the nape of the neck. Even if the residual noise is increased, the use of noncephalic reference results in a more reliable detection of wave V compared to the conventional locations of the reference electrode.


  • Kontralaterale Beeinflussung transitorisch evozierter otoakustischer Emissionen*

    by M. Ganz, H. von Specht, Z. Kevanishvili

    In recent publications the influence of contralateral white noise on transient evoked otoacoustic emissions (TEOAE) is discussed with regard on contributions of the efferent auditory system. In the present study the effects have been investigated with regards to middle-ear muscles, efferents and cross hearing. TEOAE to monaural 40-80 dB SPL clicks were recorded in normal-hearing adults under simultaneous presentation of 20-60 dB SPL broadband noise to the contralateral ear. Control runs were performed before, during a short break of, and after contralateral stimulation. The control run before contralateral stimulation was used as a reference. Decrease in TEOAE, and increase in accompanying noise floor, were found to follow the contralateral stimulation. In particular a 1-3 dB decrease was found for contralateral noise levels of 40 and 60 dB SPL, even though the readings at 60 dB only were statistically significant (paired-samples t test, p = 0.05). For both TEOAE and noise floor no systematic dependence on click intensity was seen. The control runs during temporary break and after contralateral noise revealed an increase in both TEOAE and noise floor. As a rule, the TEOAE adapted to the reference within 2-3 min following the cessation of contralateral stimulation, whereas the increased noise floor level was still noted after 10 min. Traditionally, suppressing effects of contralateral stimulation on TEOAE have been attributed to cochlear efferents (CEs). Occasionally, the middle-ear muscle and cross hearing involvement have been considered as well. Substantially, the present results and findings of other workers are inconsistent with the basic knowledge of CE functioning: (I) The decrease in TEOAE under contralateral stimulation is in conflict with an increase in cochlear microphonics and summating potentials observed during activation of CEs: (II) contralateral suppression of TEOAE exhibited no significant dependence on the test-stimulus level while the CEs are known to be efficient in the range of the low signal intensities only, and (III) acoustic activation of the CEs can hardly be expected to reach levels sufficient to influence the TEOAE mechanism. The present findings, i.e. decrease in TEOAE and increase in noise floor level, can more reasonably be explained as being mainly attributable to activation of the middle-ear muscles.

    • 1 January 1993
      • Vol. 31  (5) , 321-9

    [Diagnosis of hearing disorders in premature infants].

    by K Begall, J Pethe, H Von Specht, H Köditz

    In cases of severe hearing loss in babies an early rehabilitation should prevent a delay in development. More than a half of all hearing disorders in children are acquired; to a large extend these hearing disorders are caused by premature birth and can be detected by suitable screening. Two methods are used for testing: (1) reflex audiometry with a standardized stimulus generator; and (2) bedside recording of brainstem potentials. Having tested the method of bedside recording of brainstem potentials a group of 60 premature infants of varied body weights and no additional diseases was examined as "normal" control group. Only premature birth with all signs of maturation adequate for gestational age is not a greater risk for hearing disorders. In premature infants with birth weights less than 1500 g, having marked hyperbilirubinemia and extensive intracranial bleeding always increased wave V latencies has been observed. In about 10% of these children severe hearing disorders were diagnosed and after leaving the premature department were sent to a paedaudiological dispensaire.


    • 1 January 1988
      • Vol. 27  (3) , 183-8

    [Use of auditory evoked potentials of early and medium latency in pediatric audiology].

    by K Begall, J Pethe, H Von Specht, R Preibisch-Effenberger