PAP F Abate

P F Abate

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


P F Abate has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 1 January 2001
      • Vol. 14, 14-7

    Adhesion of composite to air-abraded enamel and dentin.

    by P F Abate, M J Molina, R L Macchi

    The purpose of this study was to compare the shear bond strength of a resin composite to air abraded and not air abraded enamel and dentin surfaces, and to evaluate the need for acid conditioning before the application of a single component adhesive. Enamel (E) and dentin (D) flat surfaces were obtained from a pool of recently extracted human teeth (30 incisors and 30 molars) and prepared with different treatments with and without the application of air abrasion (AA) and phosphoric acid (PA). Composite samples were bonded to the surfaces and stored in distilled water at 37 degrees C. After 24 hours, shear bond strength tests were carried out with an Instron machine and the results were subjected to statistical analysis. Maximum bond strength was obtained in the E + AA + PA group (34.74 MPa--2.70), followed by: E + PA (31.26 MPa--1.87); D + PA (24.09-1.72); D + AA + PA (20.61 MPa--1.79); D + AA (8.96 MPa--0.82) and E + AA (7.17 MPa--1.75). The results were significantly lower in those groups that were not acid conditioned (P < 0.01). The bond strength of composite to enamel was slightly increased as a result of the combination of AA with PA. However, the opposite effect was observed on dentin surfaces. Acid etching is a necessary clinical step even on air abraded surfaces.


  • Evaporation of solvent in one-bottle adhesives

    by P.F. Abate, V.I. Rodriguez, R.L. Macchi


    • 1 March 1999
      • Vol. 30  (3) , 193-7

    Solubility and fluoride release in ionomers and compomers.

    by S M Bertacchini, P F Abate, A Blank, M F Baglieto, R L Macchi

    The degree of solubility and the fluoride release of glass-ionomer cements and "compomers" were determined as a function of time. Three conventional glass-ionomer cements, three hybrid ionomers, and two compomers were included in the study. Disk-shaped specimens were prepared and immersed in a lactic acid solution. Solubility was evaluated from determinations of loss of mass as a function of time. To evaluate fluoride release, similar specimens were immersed in 50 mL of deionized water to which 50 mL of buffer solution was added. A fluoride ion detector was used to read the concentration of fluoride ion in the overall solution at different times after immersion. Material and time factors had a significant influence on results. The compomers showed less corrosion and fluoride release than the ionomers. Some correlation was found between solubility and fluoride leakage values. Components of both the ionomers and compomers that were studied can dissolve in water. The materials leak fluoride ions in amounts that differ according to the characteristics of the individual products.


  • Antimicrobial effect of six endodontic sealers: an in vitro evaluation

    by A. E. Kaplan, M. Picca, M. I. Gonzalez, R. L. Macchi, S. L. Molgatini

    — The aim of this study was to determine the in vitro antimicrobial effect of six endodontic sealers after 2, 20 and 40 days. The sealers studied were Apexit, Endion, AH26, AH‐Plus, Procosol and Ketac Endo. The microorganisms used were Candida albicans, Stnphylococcus aureus, Streptococcus mutans and Actinomyces israelii. Petri dishes were filled with sterile agar and 0.1‐ml wells were prepared and filled with the sealers. The agar plates were stored for 24 h at 37°C. The samples were then removed, immersed in 4.5 ml of culture medium and divided into three groups. The samples in group 1 were stored for 2 days at 37°C whereas the samples of groups 2 and 3 were stored at 4°C for 20 and 40 days respectively. The samples were then removed and discarded, and 0.1 ml of the culture medium was seeded on the agar plates in order to perform colony forming unit counts. Apexit, Endion and AH‐Plus produced slight inhibition on Streptococcus mutans at 20 days and on Actinomyces israelii at every time interval. No effect was found on Candida albicans and Staphylococcus aureus. Ketac Endo only produced an antimicrobial effect on Actinomyces israelii at 2 and 40 days. AH26 and Procosol showed antimicrobial effect at 40 days on Candida albicans, at 20 and 40 days on Streptococcus mutans and Staphylococcus aureus, and an effective inhibition on Actinomyces israelii at every time interval. Statistical analysis revealed both sealers and microorganisms to be significant factors affecting results in groups 2 and 3. In conclusion, the sealers evaluated in this study showed different inhibitory effects depending on time span. Overall, sealers containing eugenol and formaldehyde proved to be most effective against the microorganisms at the time intervals studied.


    • 1 August 1997
      • Vol. 28  (8) , 509-12

    Adhesion of a compomer to dental structures.

    by P F Abate, S M Bertacchini, M A Polack, R L Macchi

    The objective of this study was to evaluate the bond strength of a compomer to dental enamel, dentin, and cementum. Flat surfaces of these tissues were obtained from recently extracted human teeth. The different substrates were either treated with PSA (a primer and adhesive) or acid etched (35% phosphoric acid gel) and treated with PSA. Cylindrical specimens of compomer were then bonded to the substrates. Shear bond strength was determined after a 24-hour immersion in 37 degrees C water. Significant differences were found between both treatments on enamel, while none were found on dentin or cementum. The use of acid etchant on enamel as a surface-conditioning step previous to priming with PSA allowed a better bond between Dyract compomer and that substrate; acid etching was not particularly needed on dentin and cementum.


    • 1 May 1997
      • Vol. 28  (5) , 345-8

    Barcoll hardness of resin-modified glass-ionomer cements and a compomer.

    by P F Abate, M A Polack, R L Macchi

    The objective of this study was to evaluate the influence of several factors on the hardness of resin-modified glass-ionomer cements (hybrid ionomers) and polyacid-modified resin composites (compomers). Disk-shaped specimens were prepared from the following materials: Vitremer, Fuji II LC, Photac-Fil, and Dyract. Three specimens of each product were irradiated with a light-curing device and three were not. Barcoll hardness was determined on both sides of the specimen 10 minutes after irradiation and after 48 hours of immersion in 37 degrees C water. A factorial design was used to evaluate the factors that influenced the results. The Dyract group that was not light cured was not included in the analysis because the product did not harden under this circumstance. Analysis of variance revealed a significant effect of material, time, and specimen side when light curing was carried out. The use or nonuse of light curing was also significant. For some hybrid ionomers (e.g., Photac-Fil), light curing is a more essential step than for others to obtain adequate hardness values.


    • 1 January 1996
      • Vol. 9  (1) , 13-9

    Germicide effect of several glass ionomer cements.

    by S L Molgatini, S M Bertacchini, P F Abate, R L Macchi, M B Negroni

    One the most significant characteristics of glass ionomer cements is their ability to release fluoride compounds. This study was carried out to try establish relationships between this property and the possible effect on the growth of microorganisms that are found in carious lesions, Agar BHI medium containing Petri dishes were flooded with strains of Actinomyces naeslundii, Actinomyces israelii and Actinomyces odontolyticus. Cavities were then prepared in the agar and filled with mixtures of several glass ionomer cements. Some of them were polymerizable resin containing products. A zinc phosphate and a zinc oxide-eugenol cement were used as controls. After a seven day incubation at 37 degrees C under anaerobic conditions the inhibition halos around the specimens were measured in a way similar to that used for antibiograms. The statistical analysis of the results showed no significant differences among Actinomyces strains but a significant difference one among cements. Even when no definitive conclusions could be drawn it is worth taking into consideration the effect of glass ionomer cements on microorganisms such as the Actinomyces and continuing studies to establish more clearly what is required from the material to produce a clinically significant outcome.

    • 1 January 1996
      • Vol. 9  (1) , 21-6

    Shear bond strength of adhesive composite systems to human dentin.

    by P F Abate, M Polack, J I Stefanoni, R L Macchi

    This study was carried out to evaluate the following adhesive systems under different conditions from the point of view of the bond strength that is obtained on dentin: Scotchbond Multipurpose, 3M: Denthesive II, Kulzer; Optibond, Kerr with techniques # 1 and 5; and A.R.T. Bond. Coltene. Composite resin (Z100, 3M) cylindrical specimens were bonded to flat dentin surfaces and the adhesive strength was determined under shear. No significant differences were found between the group in which products were used with a separate step of dentin demineralization and the group in which this step is not recommended or was omitted. It can be concluded that the use of dentin acid treatment as a separate step is not necessarily required for high composite bond strength even when it could represent a convenient clinical step to prepare enamel surfaces simultaneously.