F. Javier Rubio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
F. Javier Rubio has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Edward Todd Urbansky
United States Environmental Protection Agency, Office of Research and Development, National Risk Management Research Laboratory, Water Supply and Water Resources Division, 26 West Martin Luther King Drive, Cincinnati, OH 45268, USA
2 shared publications David M. Freeman
United States Environmental Protection Agency, Office of Research and Development, National Risk Management Research Laboratory, Water Supply and Water Resources Division, 26 West Martin Luther King Drive, Cincinnati, USA
1 shared publicationMatthew L. Magnuson
United States Environmental Protection Agency, Office of Research and Development, National Risk Management Research Laboratory, Water Supply and Water Resources Division, Cincinnati, USA
1 shared publication
Latest Publications
- 9 May 2000
- Published by Royal Society of Chemistry (RSC) in Journal of Environmental Monitoring
- Vol. 2 (3) , 253-256
Ascorbic acid reduction of residual active chlorine in potable water prior to halocarboxylate determination
In studies on the formation of disinfection byproducts (DBPs), it is necessary to scavenge residual active (oxidizing) chlorine in order to fix the chlorination byproducts (such as haloethanoates) at a point in time. Such research projects often have distinct needs from requirements for regulatory compliance monitoring. Thus, methods designed for compliance monitoring are not always directly applicable, but must be adapted. This research describes an adaptation of EPA Method 552 in which ascorbic acid treatment is shown to be a satisfactory means for reducing residual oxidizing chlorine, i.e., HOCl, ClO−, and Cl2, prior to determining concentrations of halocarboxylates. Ascorbic acid rapidly reduces oxidizing chlorine compounds, and it has the advantage of producing inorganic halides and dehydroascorbic acid as opposed to halogenated organic molecules as byproducts. In deionized water and a sample of chlorinated tap water, systematic biases relative to strict adherence to Method 552 were precise and could be corrected for using similarly treated standards and analyte-fortified (spiked) samples. This was demonstrated for the quantitation of chloroethanoate, bromoethanoate, 2,2-dichloropropanoate (dalapon), trichloroethanoate, bromochloroethanoate, and bromodichloroethanoate when extracted, as the acids, into tert-butyl methyl ether (MTBE) and esterified with diazomethane prior to gas chromatography with electron capture detection (GC-ECD). Recoveries for chloroethanoate, bromoethanoate, dalapon, dichloroethanoate, trichloroethanoate, bromochloroethanoate, bromodichloroethanoate, dibromoethanoate, and 2-bromopropanoate at concentrations near the lower limit of detection were acceptable. Ascorbic acid reduction appears to be the best option presently available when there is a need to quench residual oxidants fast in a DBP formation study without generating other halospecies but must be implemented cautiously to ensure no untoward interactions in the matrix.
- 9 May 2000
- Published by Royal Society of Chemistry (RSC) in Journal of Environmental Monitoring
- Vol. 2 (3) , 253-256
Ascorbic acid reduction of residual active chlorine in potable water prior to halocarboxylate determination
In studies on the formation of disinfection byproducts (DBPs), it is necessary to scavenge residual active (oxidizing) chlorine in order to fix the chlorination byproducts (such as haloethanoates) at a point in time. Such research projects often have distinct needs from requirements for regulatory compliance monitoring. Thus, methods designed for compliance monitoring are not always directly applicable, but must be adapted. This research describes an adaptation of EPA Method 552 in which ascorbic acid treatment is shown to be a satisfactory means for reducing residual oxidizing chlorine, i.e., HOCl, ClO−, and Cl2, prior to determining concentrations of halocarboxylates. Ascorbic acid rapidly reduces oxidizing chlorine compounds, and it has the advantage of producing inorganic halides and dehydroascorbic acid as opposed to halogenated organic molecules as byproducts. In deionized water and a sample of chlorinated tap water, systematic biases relative to strict adherence to Method 552 were precise and could be corrected for using similarly treated standards and analyte-fortified (spiked) samples. This was demonstrated for the quantitation of chloroethanoate, bromoethanoate, 2,2-dichloropropanoate (dalapon), trichloroethanoate, bromochloroethanoate, and bromodichloroethanoate when extracted, as the acids, into tert-butyl methyl ether (MTBE) and esterified with diazomethane prior to gas chromatography with electron capture detection (GC-ECD). Recoveries for chloroethanoate, bromoethanoate, dalapon, dichloroethanoate, trichloroethanoate, bromochloroethanoate, bromodichloroethanoate, dibromoethanoate, and 2-bromopropanoate at concentrations near the lower limit of detection were acceptable. Ascorbic acid reduction appears to be the best option presently available when there is a need to quench residual oxidants fast in a DBP formation study without generating other halospecies but must be implemented cautiously to ensure no untoward interactions in the matrix.
- 12 April 2000
- Published by Royal Society of Chemistry (RSC)
- Vol. 2 (3) , 248-252
Avoiding pitfalls in the determination of halocarboxylic acids: the photochemistry of methylation
Haloethanoic (haloacetic) acids are formed during chlorination of drinking water and are regulated by the Environmental Protection Agency (EPA). These compounds are normally quantified by gas chromatography with electron capture detection (GC-ECD) as the methyl esters. EPA Method 552 uses diazomethane (CH2N2) for this purpose, but has only been validated by EPA for HAA6: chloro-, dichloro-, bromo-, dibromo-, bromochloro- and trichloroacetic acids. EPA Method 552.2 was developed and validated for all nine analytes (HAA9 = HAA6 + dibromochloro-, bromodichloro- and tribromoethanoic acids). Since the promulgation of Method 552.2, which uses acidic methanol, a debate has ensued over discrepancies observed by various laboratories when using diazomethane instead. In an effort to identify and eliminate potential sources for these discrepancies, a comparative study was undertaken for HAA9. Better accuracy and precision were observed for all HAA9 species by Method 552.2; recoveries were satisfactory in de-ionized and tap water. Method 552 remains satisfactory for HAA6. Systematic differences in instrumental response are observed for the two methods, but these are precise and may be accounted for using similarly treated standards and analyte-fortified (spiked) samples. That notwithstanding, Method 552 (CH2N2) was shown to be unsuitable for dibromochloro-, bromodichloro- and tribromoethanoic acids (HAA9–6). The primary problem appears to be a photoactivated reaction between diazomethane and the HAA9–6 analytes; however, side reactions were found to occur even in the dark. Analyte loss is most pronounced under typical laboratory lighting (white F40 fluorescent lamps + sunlight), but it is also observed under Philips gold F40 lamps (λ ≥ 520 nm), and in the dark.
- 12 April 2000
- Published by Royal Society of Chemistry (RSC)
- Vol. 2 (3) , 248-252
Avoiding pitfalls in the determination of halocarboxylic acids: the photochemistry of methylation
Haloethanoic (haloacetic) acids are formed during chlorination of drinking water and are regulated by the Environmental Protection Agency (EPA). These compounds are normally quantified by gas chromatography with electron capture detection (GC-ECD) as the methyl esters. EPA Method 552 uses diazomethane (CH2N2) for this purpose, but has only been validated by EPA for HAA6: chloro-, dichloro-, bromo-, dibromo-, bromochloro- and trichloroacetic acids. EPA Method 552.2 was developed and validated for all nine analytes (HAA9 = HAA6 + dibromochloro-, bromodichloro- and tribromoethanoic acids). Since the promulgation of Method 552.2, which uses acidic methanol, a debate has ensued over discrepancies observed by various laboratories when using diazomethane instead. In an effort to identify and eliminate potential sources for these discrepancies, a comparative study was undertaken for HAA9. Better accuracy and precision were observed for all HAA9 species by Method 552.2; recoveries were satisfactory in de-ionized and tap water. Method 552 remains satisfactory for HAA6. Systematic differences in instrumental response are observed for the two methods, but these are precise and may be accounted for using similarly treated standards and analyte-fortified (spiked) samples. That notwithstanding, Method 552 (CH2N2) was shown to be unsuitable for dibromochloro-, bromodichloro- and tribromoethanoic acids (HAA9–6). The primary problem appears to be a photoactivated reaction between diazomethane and the HAA9–6 analytes; however, side reactions were found to occur even in the dark. Analyte loss is most pronounced under typical laboratory lighting (white F40 fluorescent lamps + sunlight), but it is also observed under Philips gold F40 lamps (λ ≥ 520 nm), and in the dark.