J P Frölke
Research Subjects
J P Frölke has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
F C Bakker
2 shared publicationsH J Haarman
2 shared publicationsFred C Bakker
VU University Amsterdam
1 shared publicationH Van De Krol
1 shared publicationHenk J.TH.M Haarman
VU University Amsterdam
1 shared publicationKlaas Boshuizen
VU University Amsterdam
1 shared publication
Latest Publications
- 1 January 2001
- Published by Wolters Kluwer Health in The Journal of Trauma: Injury, Infection, and Critical Care
- Vol. 50 (1) , 65-70
Reaming Debris in Osteotomized Sheep Tibiae
Reamed nailing gives better fracture healing than unreamed nailing in operative treatment of fractures and nonunions. This study investigates the effect of isolated reaming debris on fracture healing in an animal model. Thirty sheep were treated with an osteotomy of the tibia with 5-mm distraction. In one group, the osteotomy gap was left empty; in the second group, the gap was packed with reaming debris from the ipsilateral femur; and in the third group, the gap was packed with cancellous bone from the iliac crest. At follow-up, callus volume was measured on standard radiographs. After 3 weeks, callus volume from the reaming debris group as well as the iliac crest group had increased significantly compared with the empty group. This study shows that isolated reaming debris supports callus building as much as conventional bone grafting, which might explain why fractures heal with more callus formation when treated with reamed nailing compared with unreamed nailing.
- 1 January 2001
- Published by Wolters Kluwer Health in The Journal of Trauma: Injury, Infection, and Critical Care
- Vol. 50 (1) , 65-70
Reaming Debris in Osteotomized Sheep Tibiae
Reamed nailing gives better fracture healing than unreamed nailing in operative treatment of fractures and nonunions. This study investigates the effect of isolated reaming debris on fracture healing in an animal model. Thirty sheep were treated with an osteotomy of the tibia with 5-mm distraction. In one group, the osteotomy gap was left empty; in the second group, the gap was packed with reaming debris from the ipsilateral femur; and in the third group, the gap was packed with cancellous bone from the iliac crest. At follow-up, callus volume was measured on standard radiographs. After 3 weeks, callus volume from the reaming debris group as well as the iliac crest group had increased significantly compared with the empty group. This study shows that isolated reaming debris supports callus building as much as conventional bone grafting, which might explain why fractures heal with more callus formation when treated with reamed nailing compared with unreamed nailing.
- 1 October 2000
- Vol. 66 (4) , 337-40
Destination of debris during intramedullary reaming. An experimental study on sheep femurs.
This study was designed to further explain the better fracture healing in fractures treated with a reamed nail. It investigates the location and quantity of the reaming debris in an ex vivo animal model to test the autograft theory. In 10 cadaveric sheep femurs, a 5-mm semicircular gap was created at the midshaft. The medullary cavity was opened and the reaming debris that dropped from the gap during reaming and the debris from the proximal opening were collected and weighed separately. The mean harvest of reaming debris at the gap was 0.99 g +/- 0.12 g (24%) and from the proximal opening at the medullary cavity 3.08 g +/- 0.31 g (76%) (total 4.07 +/- 0.34 g). This study proves that a significant amount of reaming debris collects at an artificial fracture gap during reaming of the medullary cavity. This finding supports the theory of bone autografting.
- 1 October 2000
- Vol. 66 (4) , 337-40
Destination of debris during intramedullary reaming. An experimental study on sheep femurs.
This study was designed to further explain the better fracture healing in fractures treated with a reamed nail. It investigates the location and quantity of the reaming debris in an ex vivo animal model to test the autograft theory. In 10 cadaveric sheep femurs, a 5-mm semicircular gap was created at the midshaft. The medullary cavity was opened and the reaming debris that dropped from the gap during reaming and the debris from the proximal opening were collected and weighed separately. The mean harvest of reaming debris at the gap was 0.99 g +/- 0.12 g (24%) and from the proximal opening at the medullary cavity 3.08 g +/- 0.31 g (76%) (total 4.07 +/- 0.34 g). This study proves that a significant amount of reaming debris collects at an artificial fracture gap during reaming of the medullary cavity. This finding supports the theory of bone autografting.