KPKarine Provost

Karine Provost

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Karine Provost has a total of 112 co-authors. Here are the top co-authors by number of shared publications:

  • Amelia Strom

    Memory and Aging Center, Department of Neurology, Weill Institute for Neurosciences, University of California San Francisco, San Francisco, CA, USA

    3 shared publications
  • Lauren Edwards

    Memory and Aging Center, Department of Neurology, Weill Institute for Neurosciences, University of California San Francisco, San Francisco, CA, USA

    3 shared publications
  • Leonardo Iaccarino

    Memory and Aging Center, Department of Neurology, Weill Institute for Neurosciences, University of California San Francisco, San Francisco, CA, USA

    3 shared publications
  • Mustafa Janabi

    Molecular Biophysics and Integrated Bioimaging, Lawrence Berkeley National Laboratory, Berkeley, CA, USA

    3 shared publications
  • Gil D Rabinovici

    Molecular Biophysics and Integrated Bioimaging, Lawrence Berkeley National Laboratory, Berkeley, CA, USA

    2 shared publications
  • Gil D. Rabinovici

    Memory and Aging Center, Department of Neurology, University of California San Francisco, San Francisco, USA

    2 shared publications

Latest Publications

  • Open Access

    Comparison of Plasma p-tau217 and [ 18 F]FDG-PET for Identifying Alzheimer Disease in People With Early-Onset or Atypical Dementia

    by Kely Monica Quispialaya, Joseph Therriault, Antonio Aliaga, Andrea L. Benedet, Nicholas J. Ashton, Thomas Karikari, Arthur Cassa Macedo, Nesrine Rahmouni, Cécile Tissot, Jaime Fernandez Arias, et al.

    To compare the diagnostic performance of an immunoassay for plasma concentrations of phosphorylated tau (p-tau) 217 with visual assessments of fluorine-18 fluorodeoxyglucose [18F]FDG-PET in individuals who meet appropriate use criteria for Alzheimer dementia (AD) biomarker assessments. We performed a retrospective analysis of individuals with early-onset (age 18F]FDG-PET scans, amyloid-PET scans, and plasma p-tau217 quantifications. To determine whether the [18F]FDG-PET images were compatible with AD, images were visually rated by 2 nuclear medicine experts. Using a contingency analysis, we evaluated the accuracy of [18F]FDG-PET scan interpretation and plasma p-tau217 for an AD biomarker profile in CSF and for amyloid-PET positivity. A total of 81 individuals with early onset and/or atypical dementia were included in this study (mean age = 65 years; 48/81 female (59%). Both [18F]FDG-PET and plasma p-tau217 showed high levels of agreement with reference standard AD biomarkers ([18F]FDG-PET area under the curve [AUC]: 71%; plasma p-tau217 AUC: 81%). Although both biomarkers had similar specificity for AD [18F]FDG-PET: 70%, CI: 0.56-0.81; plasma p-tau217: 70%, CI: 0.56-0.81), plasma p-tau217 had higher sensitivity for AD (plasma p-tau217: 97%, CI: 0.85-0.99 vs [18F]FDG-PET: 73%, CI: 0.57-0.85) (p = 0.01). Overall accuracy was also higher for plasma p-tau217 (AUC = 84%, CI: 0.75-0.93 vs 72%, CI: 0.60-0.83 of [18F]FDG-PET) (p = 0.02). The same pattern of results was observed when using amyloid-PET as the reference standard. Our study provides evidence that plasma p-tau217 has strong discriminative accuracy for AD among patients with early-onset and/or atypical dementia assessed in specialized settings. Future work should replicate these findings in secondary care settings.


  • A retinal deep phenotypingTM platform to predict the cerebral amyloid PET status in older adults

    by Jean‐Paul Soucy, Claudia Chevrefils, Sam Osseiran, Jean‐Philippe Sylvestre, Frédéric Lesage, Sylvain Beaulieu, Tharick A. Pascoal, Karine Provost, Jean Daniel Arbour, Marc‐André Rhéaume, et al.

    Background: As the only optically accessible part of the central nervous system, the retina represents an intriguing opportunity for the detection of biomarkers for Alzheimer’s disease (AD). This study evaluated the performance of the Retinal Deep PhenotypingTM platform, a digital biomarker platform comprising a hyperspectral retinal camera and image analysis algorithms, for the detection of likely positron‐emission tomography (PET) amyloid status (negative or positive) in older adults. A set of phenotypic features that correlates with the cerebral amyloid status as determined by amyloid PET scan were identified and used to train a classifying algorithm.Method: Hyperspectral retinal images acquired with a Mydriatic Hyperspectral Retinal Camera from 194 participants (age ≥ 50 years), including cognitively normal and cognitively impaired (mild cognitive impairment and dementia) across 5 imaging sites were processed in order to train the model. Of these 194 participants, 73 individuals (38%) were amyloid‐positive, as confirmed by unanimous readings of PET scans by a panel of 3 expert reviewers. The pre‐processed hyperspectral images were segmented into various anatomical sites, and a texture‐based approach was used to extract several thousands of spatial‐spectral features. The most relevant features for the classification task were selected using a minimum redundancy maximum relevance (MRMR) algorithm and used to train a linear support vector machine (SVM) classifier. A nested, cross‐validation technique was used to evaluate the performance of the classifier.Result: The resulting model based on the 17 most significant features showed high performance to discriminate between amyloid positive and negative subjects with an area under the receiver operating curve (AUCROC) of 0.87 (95% CI: 0.83 – 0.92).Conclusion: The Retinal Deep PhenotypingTM platform shows promise for detecting the likely cerebral amyloid PET status in adults 50 years and older from a simple, non‐invasive retinal scan and could provide an accessible means to identify individuals with abnormal cerebral amyloid in a clinical or drug development context. This phenotyping platform provides a flexible approach that could also be used for the detection of multiple biomarkers involved in cognitive decline from the same hyperspectral images of the retina.


  • Phase diagram and order-disorder transitions in Y0.9Gd0.1Fe2Hx hydrides (x ≥ 2.9)

    by V. Paul-Boncour, K. Provost, E. Alleno, A. N’diaye, F. Couturas, E. Elkaim


  • Abnormal tau in amyloid PET negative individuals

    by Bora Yoon, Tengfei Guo, Karine Provost, Deniz Korman, Tyler J. Ward, Susan M. Landau, William J Jagust


  • Evaluation of [18F]-JNJ-64326067-AAA tau PET tracer in humans

    by Suzanne L Baker, Karine Provost, Wesley Thomas, Aj Whitman, Mustafa Janabi, Mark E Schmidt, Maarten Timmers, Hartmuth C Kolb, Gil D Rabinovici, William J Jagust

    The [18F]-JNJ-64326067-AAA ([18F]-JNJ-067) tau tracer was evaluated in healthy older controls (HCs), mild cognitive impairment (MCI), Alzheimer’s disease (AD), and progressive supranuclear palsy (PSP) participants. Seventeen subjects (4 HCs, 5 MCIs, 5 ADs, and 3 PSPs) received a [11C]-PIB amyloid PET scan, and a tau [18F]-JNJ-067 PET scan 0-90 minutes post-injection. Only MCIs and ADs were amyloid positive. The simplified reference tissue model, Logan graphical analysis distribution volume ratio, and SUVR were evaluated for quantification. The [18F]-JNJ-067 tau signal relative to the reference region continued to increase to 90 min, indicating the tracer had not reached steady state. There was no significant difference in any bilateral ROIs for MCIs or PSPs relative to HCs; AD participants showed elevated tracer relative to controls in most cortical ROIs (P < 0.05). Only AD participants showed elevated retention in the entorhinal cortex. There was off-target signal in the putamen, pallidum, thalamus, midbrain, superior cerebellar gray, and white matter. [18F]-JNJ-067 significantly correlated (p < 0.05) with Mini-Mental State Exam in entorhinal cortex and temporal meta regions. There is clear binding of [18F]-JNJ-067 in AD participants. Lack of binding in HCs, MCIs and PSPs suggests [18F]-JNJ-067 may not bind to low levels of AD-related tau or 4 R tau.


  • Crossed cerebellar diaschisis on 18F-FDG PET: Frequency across neurodegenerative syndromes and association with 11C-PIB and 18F-Flortaucipir

    by Karine Provost, Renaud La Joie, Amelia Strom, Leonardo Iaccarino, Lauren Edwards, Taylor J Mellinger, Julie Pham, Suzanne L Baker, Bruce L Miller, William J Jagust, et al.

    We used 18F-FDG-PET to investigate the frequency of crossed cerebellar diaschisis (CCD) in 197 patients with various syndromes associated with neurodegenerative diseases. In a subset of 117 patients, we studied relationships between CCD and cortical asymmetry of Alzheimer’s pathology (β-amyloid (11C-PIB) and tau (18F-Flortaucipir)). PET images were processed using MRIs to derive parametric SUVR images and define regions of interest. Indices of asymmetry were calculated in the cerebral cortex, basal ganglia and cerebellar cortex. Across all patients, cerebellar 18F-FDG asymmetry was associated with reverse asymmetry of 18F-FDG in the cerebral cortex (especially frontal and parietal areas) and basal ganglia. Based on our operational definition (cerebellar asymmetry >3% with contralateral supratentorial hypometabolism), significant CCD was present in 47/197 (24%) patients and was most frequent in corticobasal syndrome and semantic and logopenic variants of primary progressive aphasia. In β-amyloid-positive patients, mediation analyses showed that 18F-Flortaucipir cortical asymmetry was associated with cerebellar 18F-FDG asymmetry, but that cortical 18F-FDG asymmetry mediated this relationship. Analysis of 18F-FDG-SUVR values suggested that CCD might also occur in the absence of frank cerebellar 18F-FDG asymmetry due to symmetrical supratentorial degeneration resulting in a bilateral diaschisis process.


  • Comparing ATN-T designation by tau PET visual reads, tau PET quantification, and CSF PTau181 across three cohorts

    by Karine Provost, Leonardo Iaccarino, David N. Soleimani-Meigooni, Suzanne Baker, Lauren Edwards, Udo Eichenlaub, Oskar Hansson, William Jagust, Mustafa Janabi, Renaud La Joie, et al.

    Purpose To compare rates of tau biomarker positivity (T-status) per the 2018 Alzheimer’s Disease (AD) Research Framework derived from [18F]flortaucipir (FTP) PET visual assessment, FTP quantification, and cerebrospinal fluid (CSF) phosphorylated Tau-181 (PTau181). Methods We included 351 subjects with varying clinical diagnoses from three cohorts with available FTP PET and CSF PTau181 within 18 months. T-status was derived from (1) FTP visual assessment by two blinded raters; (2) FTP standardized uptake value ratio (SUVR) quantification from a temporal meta-ROI (threshold: SUVR ≥1.27); and (3) Elecsys® Phospho-Tau (181P) CSF (Roche Diagnostics) concentrations (threshold: PTau181 ≥ 24.5 pg/mL). Results FTP visual reads yielded the highest rates of T+, while T+ by SUVR increased progressively from cognitively normal (CN) through mild cognitive impairment (MCI) and AD dementia. T+ designation by CSF PTau181 was intermediate between FTP visual reads and SUVR values in CN, similar to SUVR in MCI, and lower in AD dementia. Concordance in T-status between modality pairs ranged from 68 to 76% and varied by clinical diagnosis, being highest in patients with AD dementia. In discriminating Aβ + MCI and AD subjects from healthy controls and non-AD participants, FTP visual assessment was most sensitive (0.96) but least specific (0.60). Specificity was highest with FTP SUVR (0.91) with sensitivity of 0.89. Sensitivity (0.73) and specificity (0.72) were balanced for PTau181. Conclusion The choice of tau biomarker may differ by disease stage and research goals that seek to maximize sensitivity or specificity. Visual interpretations of tau PET enhance sensitivity compared to quantification alone, particularly in early disease stages.


  • Comparison of 18F‐Flortaucipir visual assessment, SUVR quantification and CSF pTau for defining T‐status in the AT(N) framework

    by Karine Provost, Leonardo Iaccarino, David N. Soleimani‐Meigooni, Orit H. Lesman‐Segev, Renaud Joie, Niklas Mattsson, Oskar Hansson, Udo Eichenlaub, Lauren Edwards, Amelia Strom, et al.

    Background: Tau‐PET is included in the AT(N) research framework to define T‐status. However, no consensus exists as to how to classify patients as T+ or T‐ with this modality. We aim to compare T‐status derived from 18F‐Flortaucipir (FTP) PET visual assessment, 18F‐FTP SUVR quantification, and CSF pTau.Methods: 278 subjects who underwent 18F‐FTP PET and CSF analysis within 1 year were included from UCSF and ADNI. The cohort consisted of a continuum from cognitively normal controls (CN) to Alzheimer’s disease dementia (AD), and non‐Alzheimer’s disorders (clinical diagnoses, Table 1). T‐status was derived from: (1) 18F‐FTP consensus between two readers performing blinded visual assessment based on a priori criteria (Figure 1, inter‐rater k=0.68, 95%CI 0.59‐0.76; Provost et al, HAI Conference, 2020); (2) 18F‐FTP SUVR quantification of from a temporal meta‐ROI using a previously validated threshold (SUVR >1.27, Ossenkoppele et al. 2018); (3) Elecsys® Phospho‐Tau (181P) CSF (Roche Diagnostics) applying a ROC‐based threshold derived from an external ADNI cohort comparing amyloid‐positive AD vs. healthy controls (pTau >24.5 pg/mL).Results: T+ was assigned in a higher proportion of AD, MCI and amyloid‐positive CN with 18F‐FTP visual assessment compared to 18F‐FTP SUVR and CSF pTau (Table 2). However, visual ratings also yielded the highest proportion of T+ in amyloid‐negative CN and MCI. Contrasting amyloid‐positive AD/MCI with other groups, sensitivity was highest for 18F‐FTP visual assessment, while specificity was highest for 18F‐FTP SUVR (Table 3). In a subset of patients with autopsy (n=11), T‐status derived from 18F‐FTP visual assessment had an accuracy of 100%, compared to 82% for SUVR quantification and 64% for CSF pTau. Overall agreement between the 3 classification criteria ranged from 68% to 76% in the whole cohort (Figure 2) and was highest in patients with AD (94%). Patients with concordant T‐status across all three modalities were significantly younger, had higher CSF pTau, higher 18F‐FTP SUVR (Figure 3), and were more likely to be amyloid positive.Conclusions: Concordance of T‐status derived from 18F‐FTP visual assessment, SUVR quantification and CSF pTau varies across disease stage, being highest in AD. 18F‐FTP visual assessment offers highest sensitivity, while SUVR threshold maximizes specificity.

  • Open Access

    Reproducibility of Lobar Perfusion and Ventilation Quantification Using SPECT/CT Segmentation Software in Lung Cancer Patients

    by Karine Provost, Antoine Leblond, Annie Gauthier-Lemire, Édith Filion, Houda Bahig, Martin Lord

    Planar perfusion scintigraphy with Tc99m-labelled macroaggregated albumin (Tc99m-MAA) is often used for pre-therapy quantification of regional lung perfusion in lung cancer patients, particularly in patients with poor respiratory function. However, subdividing lung parenchyma in rectangular regions of interests, as done on planar images, is a poor reflection of true lobar anatomy. New tridimensional methods using SPECT and SPECT/CT have been introduced, including a semi-automatic lung segmentation software (Hermes Medical Solutions). The present study evaluates inter- and intraobserver agreement of quantification using a SPECT/CT software, and compares results of regional lung contribution obtained with SPECT/CT and planar scintigraphy. Methods: Thirty (30) lung cancer patients underwent ventilation perfusion (V/Q) scintigraphy with Tc99m-MAA and Tc99m-Technegas. Regional lung contribution to perfusion and ventilation was measured on both planar scintigraphy and SPECT/CT using a semi-automatic lung segmentation software by two observers. Interobserver and intraobserver agreement for SPECT/CT software were assessed using intra-class correlation coefficient (ICC), Bland Altman plots, and absolute differences of measurements. Measurements from planar and tridimensional methods were compared using paired sample t-tests, and mean absolute differences. Results: ICC were in the excellent range (above 0.9) for both interobserver and intraobserver agreement using the SPECT/CT software. Bland Altman analyses showed very narrow limits of agreement. Absolute differences were below 2.0% in 96% of both interobserver and intraobserver measurements. There was a statistically significant difference between planar and SPECT/CT methods (P<.001) for quantification of perfusion and ventilation for all right lung lobes, with a maximal mean absolute difference of 20.7% for the right middle lobe. There was no statistically significant difference for quantification of perfusion and ventilation for left lung lobes using both methods, however absolute differences reached 12.0%. Total right and left lung contribution were very similar using both methods, with a mean difference of 1.2% for perfusion and 2.0% for ventilation. Conclusion: Quantification of regional lung perfusion and ventilation using a SPECT/CT-based lung segmentation software is highly reproducible. This tridimensional method yields statistically significant differences in measurements for right lung lobes when compared to planar scintigraphy. We recommend that SPECT/CT based quantification be used for all lung cancer patients undergoing pre-therapy evaluation of regional lung function.


  • Open Access

    Detection of Intrathoracic Bleeding by 99mTc-Labeled Red Blood Cell SPECT/CT After Wedge Biopsy of Pulmonary Angiosarcoma

    by Karine Provost, Mathieu Charest

    A 52 year-old male presenting with dyspnea and massive right pleural effusion was diagnosed with pleural angiosarcoma following wedge biopsies of pulmonary lesions. Patient was investigated for post-operative bleed with CT angiography, which failed to identify the bleeding site. Technetium-99m labelled red blood cell (Tc99m-RBC) scintigraphy with SPECT/CT of the chest was performed, and the bleeding site was rapidly localized. To our knowledge, this is the first case reported in the literature of intra-thoracic bleeding localisation with SPECT/CT Tc99m-red blood cell scintigraphy.