Nico Van Eeckhout
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nico Van Eeckhout has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Carlos Van Peteghem
Laboratory of Food Analysis, Faculty of Pharmaceutical Sciences, Ghent University, Harelbekestraat 72, 9000 Ghent, Belgium
2 shared publicationsJosé Castro Perez
Micromass UK Limited, Floats Road, Wythenshawe, Manchester M23 9LZ, UK
2 shared publicationsCarlos H. Van Peteghem
1 shared publicationGuy C. Maghuin-Rogister
1 shared publicationJan Claereboudt
Micromass Belgium, Bedrijvencentrum Vilvoorde, Mechelsesteenweg 227 bus 9, 1800 Vilvoorde, Belgium
1 shared publicationMarc R. Cornelis
1 shared publication
Latest Publications
- 23 November 2000
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 14 (24) , 2331-2338
Determination of eight sulfonamides in bovine kidney by liquid chromatography/tandem mass spectrometry with on-line extraction and sample clean-up
A sensitive, high performance liquid chromatography/tandem mass spectrometric (i.e. mass spectrometry/mass spectrometry; LC/MS/MS) method with on‐line extraction and sample clean‐up for the screening and confirmation of residues of sulfonamides in kidney is described. The sulfonamides are extracted from homogenized kidney with methanol. After centrifugation of the extract, an aliquot of the extract is directly injected on the LC/MS/MS system with further extraction and clean‐up of the sample on‐line. Detection of the analytes was achieved by positive electrospray ionization (ESI) followed by multiple reaction monitoring. For each sulfonamide the collisional decomposition of the protonated molecule to a common, abundant fragment ion was monitored. The method has been validated for sulfadimethoxine, sulfaquinoxaline, sulfamethazine, sulfamerazine, sulfathiazole, sulfamethoxazole, sulfadiazine and sulfapyridine. Calibration curves resulting from spiked blank kidney samples at the 10–200 µg/kg level showed good linear correlation. At the level of 50, 100 and 200 µg/kg both within‐ and between‐day precision, as measured by relative standard deviation (RSD), were less than 16%. The limits of detection (LODs) ranged from 5 to 13.5 µg/kg. The recoveries ranged from 78 to 82%. The procedure provides a rapid, reliable and sensitive method for the determination of residues of sulfonamides in bovine kidney. The advantage of this method over existing methods is its decreased sample preparation and analysis time, which makes the method more suitable for routine analysis. Copyright © 2000 John Wiley & Sons, Ltd.
- 23 November 2000
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 14 (24) , 2331-2338
Determination of eight sulfonamides in bovine kidney by liquid chromatography/tandem mass spectrometry with on-line extraction and sample clean-up
A sensitive, high performance liquid chromatography/tandem mass spectrometric (i.e. mass spectrometry/mass spectrometry; LC/MS/MS) method with on‐line extraction and sample clean‐up for the screening and confirmation of residues of sulfonamides in kidney is described. The sulfonamides are extracted from homogenized kidney with methanol. After centrifugation of the extract, an aliquot of the extract is directly injected on the LC/MS/MS system with further extraction and clean‐up of the sample on‐line. Detection of the analytes was achieved by positive electrospray ionization (ESI) followed by multiple reaction monitoring. For each sulfonamide the collisional decomposition of the protonated molecule to a common, abundant fragment ion was monitored. The method has been validated for sulfadimethoxine, sulfaquinoxaline, sulfamethazine, sulfamerazine, sulfathiazole, sulfamethoxazole, sulfadiazine and sulfapyridine. Calibration curves resulting from spiked blank kidney samples at the 10–200 µg/kg level showed good linear correlation. At the level of 50, 100 and 200 µg/kg both within‐ and between‐day precision, as measured by relative standard deviation (RSD), were less than 16%. The limits of detection (LODs) ranged from 5 to 13.5 µg/kg. The recoveries ranged from 78 to 82%. The procedure provides a rapid, reliable and sensitive method for the determination of residues of sulfonamides in bovine kidney. The advantage of this method over existing methods is its decreased sample preparation and analysis time, which makes the method more suitable for routine analysis. Copyright © 2000 John Wiley & Sons, Ltd.
- 9 February 2000
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 14 (4) , 280-285
Determination of tetracyclines in bovine kidney by liquid chromatography/tandem mass spectrometry with on‐line extraction and clean‐up
- 9 February 2000
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 14 (4) , 280-285
Determination of tetracyclines in bovine kidney by liquid chromatography/tandem mass spectrometry with on‐line extraction and clean‐up
- 1 January 1998
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 123 (12) , 2423-2427
New database on hormone and veterinary drug residue determination in animal products†
A new database was created which provides a carefully judged inventory of analytical methods available for the determination of residues of growth promoters (steroidal anabolic hormones, β-agonists and glucocorticoids) and veterinary drugs (antibiotics and growth inhibitors), which are or will be regulated by EU legal acts. This database is available on the Internet at http://cemu10.fmv.ulg.ac.be/OSTC.
- 1 January 1998
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 123 (12) , 2423-2427
New database on hormone and veterinary drug residue determination in animal products†
A new database was created which provides a carefully judged inventory of analytical methods available for the determination of residues of growth promoters (steroidal anabolic hormones, β-agonists and glucocorticoids) and veterinary drugs (antibiotics and growth inhibitors), which are or will be regulated by EU legal acts. This database is available on the Internet at http://cemu10.fmv.ulg.ac.be/OSTC.