BSBernd-Jan Sanson

Bernd-Jan Sanson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Bernd-Jan Sanson has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparison of a Clinical Probability Estimate and Two Clinical Models in Patients with Suspected Pulmonary Embolism

    by Jeroen G. Lijmer, Jeroen G. Lijmer, Melvin R. Mac Gillavry, Melvin R. Mac Gillavry, Franktien Turkstra, Franktien Turkstra, Martin H. Prins, Martin H. Prins, Harry R. Büller, Harry R. Büller, et al.

    Recent studies have suggested that both the subjective judgement of a physician and standardized clinical models can be helpful in the estimation of the probability of the disease in patients with suspected pulmonary embolism (PE). We performed a multi-center study in consecutive in- and outpatients with suspected PE to compare the potential diagnostic utility of these methods. Of the 517 study patients, 160 (31%) were classified as having PE. Of these patients, 14% had a low probability as estimated by the treating physician, while 25 to 36% were categorized as having a low clinical probability with the use of two previously described clinical models. The objectively confirmed prevalence of PE in these three low probability categories was 19%, 28% and 28%, respectively. The three methods yielded comparable predictive values for PE in the other probability categories. We conclude that a physician’s clinical judgement alone and two standardized clinical models, although comparable, perform disappointingly in categorizing the pre-test probability in patients with suspected PE. ** Participating centers are listed in the appendix, p. 202.


  • Use of a New Monoclonal Antibody-Based Enzyme Immunoassay for Soluble Fibrin to Exclude Pulmonary Embolism

    by Bernd-Jan Sanson, Wouter de Monyé, Jeroen G. Lijmer, Menno V. Huisman, Harry R. Büller, Willem Nieuwenhuizen, Dees P. M. Brandjes, Melvin R. Mac Gillavry, the ANTELOPE-Study Group

    We prospectively evaluated the diagnostic performance of a new soluble fibrin assay in 303 consecutive patients with suspected pulmonary embolism and examined potentially useful cut-off levels at which this disease can be safely excluded. In addition, the diagnostic accuracy was calculated in the subgroups of in- and outpatients. The ROC curve of the assay in the total study cohort had an area under the curve of 0.69. The cut-off level associated with a sensitivity and negative predictive value of 100% was 20 ng/ml, but the specificity was only 4%. The cut-off level with a sensitivity of 90% was 30 ng/ml, which corresponded with a specificity and negative predictive value of 27% and 86%, respectively. The diagnostic performance was comparable in the subgroups of in- and outpatients. We conclude that the soluble fibrin assay has a low diagnostic accuracy and seems unsuitable as a screening test for the exclusion of pulmonary embolism. * Study investigators are listed in the appendix


    • 1 December 1999
      • Vol. 94  (11) , 3702-6

    The incidence of venous thromboembolism in asymptomatic carriers of a deficiency of antithrombin, protein C, or protein S: a prospective cohort study.

    by B J Sanson, P Simioni, D Tormene, M Moia, P W Friederich, M V Huisman, P Prandoni, A Bura, L Rejto, P Wells, et al.

    Deficiencies of antithrombin, protein C, and protein S are associated with an increased risk of venous thromboembolism. The objective of this study was to prospectively assess the incidence of venous thromboembolism in nontreated asymptomatic subjects with such a deficiency. We conducted a prospective cohort study in asymptomatic family members of unselected patients who presented with a venous thromboembolic event and who were found to have a deficiency of antithrombin, protein C, or protein S. No anticoagulant prophylaxis was given to the study participants, except during risk periods for venous thromboembolism. All venous thromboembolic events were diagnosed by objective diagnostic tests. A total of 208 individuals with a mean age of 37 years (range, 15 to 79) were included in the study. A total of 611 patient observation years was obtained. Nine venous thromboembolic events occurred, resulting in an annual incidence of 1.5% (95% confidence interval [CI], 0.7 to 2.8) for the 3 deficiencies combined. Five of these events occurred spontaneously, resulting in an annual incidence of spontaneous venous thromboembolism of 0.8% (95% CI, 0.3 to 1.9). For antithrombin, protein C, and protein S deficiencies separately, this figure was 1.6%, 1.0%, and 0.4%, respectively. Thirty-four subjects experienced a total of 40 risk periods during which 4 venous thromboembolic events occurred (10% per risk period). We conclude that the use of continuous anticoagulant prophylaxis seems not warranted in asymptomatic individuals with a deficiency of antithrombin, protein C, or protein S. During risk periods for venous thromboembolism, adequate anticoagulant prophylaxis is necessary.


  • Safety of Low-Molecular-Weight Heparin in Pregnancy: A Systematic Review

    by Bernd-Jan Sanson, Anthonie W. A. Lensing, Martin H. Prins, Jeffrey S. Ginsberg, Zinoviy S. Barkagan, Edith Lavenne-Pardonge, Benjamin Brenner, Mordechay Dulitzky, Jørn D. Nielsen, Zoltan Boda, et al.

    Summary: Unfractionated heparin (UFH) remains the anticoagulant of choice during pregnancy. Low-molecular-weight heparins (LMWH) are an attractive alternative to UFH due to their logistic advantages and their association with a lower incidence of osteoporosis and HIT. We reviewed all published clinical reports concerning the use of LMWH during pregnancy. In addition, participants of an international interest group contributed a cohort of pregnant women treated with LMWH. Pregnancies were divided into two groups; those with and those without maternal comorbid conditions. The number of adverse fetal outcomes and the occurrence of maternal complications were evaluated in the two groups. In the group of women with comorbid conditions (n = 290), 13.4% of the pregnancies were associated with an adverse fetal outcome. In contrast, in the group of women without comorbid conditions (n = 196), 3.1% were associated with an adverse outcome, which is comparable to that seen in the normal population. We conclude that LMWH appear to be a safe alternative to unfractionated heparin as an anticoagulant during pregnancy.