Russell H. Taylor
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Russell H. Taylor has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Peter Kazanzides
Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD 21218, USA
2 shared publications A Bzostek
1 shared publicationAlan Kalvin
1 shared publicationAlind Sahay
1 shared publication- Alison C. Barnes
Human Nutrition Research Centre, Population Health Sciences Institute, Newcastle University, Newcastle upon Tyne, UK
1 shared publication Andrew Bzostek
1 shared publication
Latest Publications
- 24 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1933-1935
Redundant Consistency Checking In A Precise Surgical Robot
- 24 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1933-1935
Redundant Consistency Checking In A Precise Surgical Robot
- 31 December 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 901-908
Hip implant insertability analysis: a medical instance of the peg-in-hole problem
An implemented algorithm for determining if an implant can be successfully inserted into a cavity is presented. The program computes an insertion trajectory consisting of small implant motion steps. Motion steps are computed by solving a series of linear optimization problems whose solution corresponds to the maximum allows displacement in a preferred direction satisfying localized motion constraints. The program implements a greedy, search-free algorithm to find a monotone trajectory in a preferred direction to any desired resolution. The program has been successfully tested on real cases Author(s) Joskowicz, L. IBM T.J. Watson Res. Center, Yorktown Heights, NY, USA Taylor, R.H.
- 31 December 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 901-908
Hip implant insertability analysis: a medical instance of the peg-in-hole problem
An implemented algorithm for determining if an implant can be successfully inserted into a cavity is presented. The program computes an insertion trajectory consisting of small implant motion steps. Motion steps are computed by solving a series of linear optimization problems whose solution corresponds to the maximum allows displacement in a preferred direction satisfying localized motion constraints. The program implements a greedy, search-free algorithm to find a monotone trajectory in a preferred direction to any desired resolution. The program has been successfully tested on real cases Author(s) Joskowicz, L. IBM T.J. Watson Res. Center, Yorktown Heights, NY, USA Taylor, R.H.
- Open Access
- 1 September 1999
- Published by Elsevier in Medical Image Analysis
- Vol. 3 (3) , 301-319
Computer-integrated revision total hip replacement surgery: concept and preliminary results
- 1 September 1999
- Published by Elsevier in Medical Image Analysis
- Vol. 3 (3) , 301-319
Open AccessComputer-integrated revision total hip replacement surgery: concept and preliminary results
- 1 October 1997
- Vol. 158 (4) , 1589-93
A robotic system for percutaneous renal access.
Percutaneous renal access can be challenging, particularly when the collecting system is not distended. Precise entry into a selected calyx facilitates subsequent percutaneous manipulations, but this skill requires extensive experience. In an attempt to improve accuracy while decreasing technical challenges, we developed a robotic system that automates the task of fluoroscopic image-guided percutaneous needle placement. The prototype system consisted of a three degree-of-freedom robot with a needle injector end-effector. Imaging was provided by a biplanar fluoroscope. After correction of image distortion and fluoroscope calibration, robot to image-space registration was completed. To validate the system's ability to insert a needle into a calyx, ex vivo porcine kidneys suspended in agarose gel and distended with iodinated contrast solution were used as a model. In situ renal access tests with three 20 kg. pigs were performed. Access was confirmed by passing a flexible wire or aspirating iodinated contrast from the collecting system. The diameter of target calyces ranged from 3 to 7 mm. The in vitro accuracy of final needle tip positioning was 0.43 mm. In the ex vivo model, successful "one stick" access occurred on 10 of 12 attempts (83%). In situ access on the first attempt was successful for 6 of 12 target calyces (50%). Needle or tissue deflection accounted for each failure. The feasibility of a robotic system to assist in the percutaneous access of small and delicate renal calyces has been demonstrated. Additional work in reducing procedural steps and correcting for tissue deflection during needle passage is necessary to improve accuracy and to allow for clinical application.
- 1 October 1997
- Vol. 158 (4) , 1589-93
A robotic system for percutaneous renal access.
Percutaneous renal access can be challenging, particularly when the collecting system is not distended. Precise entry into a selected calyx facilitates subsequent percutaneous manipulations, but this skill requires extensive experience. In an attempt to improve accuracy while decreasing technical challenges, we developed a robotic system that automates the task of fluoroscopic image-guided percutaneous needle placement. The prototype system consisted of a three degree-of-freedom robot with a needle injector end-effector. Imaging was provided by a biplanar fluoroscope. After correction of image distortion and fluoroscope calibration, robot to image-space registration was completed. To validate the system's ability to insert a needle into a calyx, ex vivo porcine kidneys suspended in agarose gel and distended with iodinated contrast solution were used as a model. In situ renal access tests with three 20 kg. pigs were performed. Access was confirmed by passing a flexible wire or aspirating iodinated contrast from the collecting system. The diameter of target calyces ranged from 3 to 7 mm. The in vitro accuracy of final needle tip positioning was 0.43 mm. In the ex vivo model, successful "one stick" access occurred on 10 of 12 attempts (83%). In situ access on the first attempt was successful for 6 of 12 target calyces (50%). Needle or tissue deflection accounted for each failure. The feasibility of a robotic system to assist in the percutaneous access of small and delicate renal calyces has been demonstrated. Additional work in reducing procedural steps and correcting for tissue deflection during needle passage is necessary to improve accuracy and to allow for clinical application.
- 1 January 1997
- Published by Springer Nature
- p. 1-11
Robots as surgical assistants: Where we are, wither we are tending, and how to get there
- 1 January 1997
- Published by Springer Nature
- p. 1-11
Robots as surgical assistants: Where we are, wither we are tending, and how to get there