T. Nikaido
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
T. Nikaido has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
J. Tagami
Tokyo Medical and Dental University, Tokyo, Japan
4 shared publicationsJ Tagami
3 shared publications- Michael Francis Burrow
The University of Melbourne
3 shared publications A. Sadr
Tokyo Medical and Dental University
2 shared publications- N. Hiraishi
Paediatric Dentistry and Orthodontics, Faculty of Dentistry, The University of Hong Kong, Prince Philip Dental Hospital, 34 Hospital Road, Pokfulam, Hong Kong SAR, China
2 shared publications A. Nazari
Tokyo Medical and Dental University
1 shared publication
Latest Publications
- 1 January 2018
- Published by Elsevier in Dental Materials
- Vol. 34, e104
Assessment of S-PRG fillers’ effect on enamel demineralization using SS-OCT
- 1 January 2018
- Published by Elsevier in Dental Materials
- Vol. 34, e104
Assessment of S-PRG fillers’ effect on enamel demineralization using SS-OCT
- 31 December 2011
- Published by Elsevier in Dental Materials
- Vol. 27, e78
Quantitative measurement of enamel lesion using micro-computed tomography and micro-radiography
- 31 December 2011
- Published by Elsevier in Dental Materials
- Vol. 27, e78
Quantitative measurement of enamel lesion using micro-computed tomography and micro-radiography
- 31 December 2011
- Published by Elsevier in Dental Materials
- Vol. 27, e22-e23
Nano-structural analysis of enamel-adhesive interface with using FIB-TEM
- 31 December 2011
- Published by Elsevier in Dental Materials
- Vol. 27, e22-e23
Nano-structural analysis of enamel-adhesive interface with using FIB-TEM
- 31 December 2011
- Published by Elsevier in Dental Materials
- Vol. 27, e18-e19
Evaluation of dentin sealing and bond strength of adhesive systems
- 31 December 2011
- Published by Elsevier in Dental Materials
- Vol. 27, e18-e19
Evaluation of dentin sealing and bond strength of adhesive systems
- 18 July 2002
- Vol. 27 (4) , 354-9
In vitro surface analysis of active and arrested dentinal caries using a pH-imaging microscope.
This in vitro study evaluated the pH value of active and arrested caries lesions in deep dentinal caries using a pH-imaging microscope (SCHEM-100, HORIBA Ltd, Kyoto, Japan). Buccal-lingual cut sections of extracted human teeth that had either active or arrested dentinal caries lesions were placed on the pH-imaging sensor of the microscope. The pH values were compared statistically by one-way ANOVA and Fisher's PLSD test (p<0.05). In addition, both types of caries lesions were compared with a caries detector solution for this pH-imaging characterization. For both active and arrested lesions in dentin, the lowest pH values in the caries lesions (range from 5.3 to 6.6) were lower than that of intact dentin (range from 6.8 to 7.4). There were statistical differences between the lowest pH value within the active lesion (range from 5.3 to 5.8) and the arrested lesion (range from 6.3 to 6.6) (p<0.05). Although the arrested lesion was unstainable and impermeable to the dye, there was a close relationship between dye staining and pH-imaging characterization within the active lesion from visual inspection.
- 18 July 2002
- Vol. 27 (4) , 354-9
In vitro surface analysis of active and arrested dentinal caries using a pH-imaging microscope.
This in vitro study evaluated the pH value of active and arrested caries lesions in deep dentinal caries using a pH-imaging microscope (SCHEM-100, HORIBA Ltd, Kyoto, Japan). Buccal-lingual cut sections of extracted human teeth that had either active or arrested dentinal caries lesions were placed on the pH-imaging sensor of the microscope. The pH values were compared statistically by one-way ANOVA and Fisher's PLSD test (p<0.05). In addition, both types of caries lesions were compared with a caries detector solution for this pH-imaging characterization. For both active and arrested lesions in dentin, the lowest pH values in the caries lesions (range from 5.3 to 6.6) were lower than that of intact dentin (range from 6.8 to 7.4). There were statistical differences between the lowest pH value within the active lesion (range from 5.3 to 5.8) and the arrested lesion (range from 6.3 to 6.6) (p<0.05). Although the arrested lesion was unstainable and impermeable to the dye, there was a close relationship between dye staining and pH-imaging characterization within the active lesion from visual inspection.
- 1 August 1999
- Vol. 12 (4) , 177-80
Bond strengths to endodontically-treated teeth.
To evaluate the bond strengths of three different types of resin bonding systems to teeth prepared for endodontic treatment. Access cavity preparation and removal of pulpal tissue were performed in bovine incisors. The root canals were chemically irrigated with saline (control), 5% sodium hypochlorite, 3% hydrogen peroxide, or combinations of both for 60 s. After storage in water for 1 d, the dentin surface was ground to a flat surface with 600-grit SiC under water. The area for bonding was demarcated with a vinyl tape (4 mm-in-diameter hole), and bonded using either Clearfil Liner Bond II, Single Bond, or Superbond C&B. After storage in 37 degrees C water for 1 d, tensile bond strengths were measured using a universal testing machine at a crosshead speed of 2 mm/min. Ten teeth were tested for each group. One-way ANOVA and Fisher's PLSD test revealed that Single Bond and Superbond C&B had a statistically lower (P < 0.05) bond strengths in the chemical irrigation groups compared with the control group.
- 1 August 1999
- Vol. 12 (4) , 177-80
Bond strengths to endodontically-treated teeth.
To evaluate the bond strengths of three different types of resin bonding systems to teeth prepared for endodontic treatment. Access cavity preparation and removal of pulpal tissue were performed in bovine incisors. The root canals were chemically irrigated with saline (control), 5% sodium hypochlorite, 3% hydrogen peroxide, or combinations of both for 60 s. After storage in water for 1 d, the dentin surface was ground to a flat surface with 600-grit SiC under water. The area for bonding was demarcated with a vinyl tape (4 mm-in-diameter hole), and bonded using either Clearfil Liner Bond II, Single Bond, or Superbond C&B. After storage in 37 degrees C water for 1 d, tensile bond strengths were measured using a universal testing machine at a crosshead speed of 2 mm/min. Ten teeth were tested for each group. One-way ANOVA and Fisher's PLSD test revealed that Single Bond and Superbond C&B had a statistically lower (P < 0.05) bond strengths in the chemical irrigation groups compared with the control group.
- 1 September 1996
- Vol. 21 (5) , 196-202
Early bonding of resin cements to dentin--effect of bonding environment.
The aim of this study was to evaluate early tensile bond strengths of three commercial resin cements (a dual-cured and two chemically cured) to bovine dentin. Bonding was performed in two environmental conditions, namely room environment (23 degrees C/50% RH) and oral environment (30 degrees C/80% RH). Tensile bond strengths were recorded at 10 minutes, 1 hour, and 1 day after the bonding procedure was completed and were analyzed using one-way ANOVA, Fisher's PLSD test, and Student's t-test. The results showed that bond strengths were statistically greater for all materials (P < 0.05) over time, except for Bistite Resin Cement between 10 minutes and 1 hour (P > 0.05). Variation between the bonding environments was observed only for Bistite Resin Cement at both 10 minutes and 1 hour, and Panavia 21 at 10 minutes. It was concluded that bond strengths were initially weak for the chemically cured materials, and all materials showed significantly greater bond strengths over the first 24 hours, but bonding environment had little influence.
- 1 September 1996
- Vol. 21 (5) , 196-202
Early bonding of resin cements to dentin--effect of bonding environment.
The aim of this study was to evaluate early tensile bond strengths of three commercial resin cements (a dual-cured and two chemically cured) to bovine dentin. Bonding was performed in two environmental conditions, namely room environment (23 degrees C/50% RH) and oral environment (30 degrees C/80% RH). Tensile bond strengths were recorded at 10 minutes, 1 hour, and 1 day after the bonding procedure was completed and were analyzed using one-way ANOVA, Fisher's PLSD test, and Student's t-test. The results showed that bond strengths were statistically greater for all materials (P < 0.05) over time, except for Bistite Resin Cement between 10 minutes and 1 hour (P > 0.05). Variation between the bonding environments was observed only for Bistite Resin Cement at both 10 minutes and 1 hour, and Panavia 21 at 10 minutes. It was concluded that bond strengths were initially weak for the chemically cured materials, and all materials showed significantly greater bond strengths over the first 24 hours, but bonding environment had little influence.
- 1 September 1996
- Vol. 21 (5) , 218-24
Bond strengths of resin to enamel and dentin treated with low-pressure air abrasion.
The effect of low-pressure (41.8 psi) air abrasion with alumina and glass beads on bonding to tooth substrates was evaluated. Tensile bond strengths of a bonding resin to air-abraded bovine enamel and dentin were measured. Scanning electron microscopy was used to observe (1) air-abraded surfaces, (2) fractured surfaces after the tensile bond test, and (3) interfaces of bonded specimens. Air abrasion with glass beads significantly decreased the bond strengths to enamel and dentin, whereas air abrasion with alumina decreased adhesion to enamel but not to dentin. The air-abraded enamel and dentin surfaces were irregularly roughened, and smear layers were created by air abrasion. Hybrid layers were observed at the interface between the bonding resin and the air-abraded dentin. The SEM photographs suggested that air abrasion may weaken the tooth surfaces, which could account for the decrease of the bond strengths.
- 1 September 1996
- Vol. 21 (5) , 218-24
Bond strengths of resin to enamel and dentin treated with low-pressure air abrasion.
The effect of low-pressure (41.8 psi) air abrasion with alumina and glass beads on bonding to tooth substrates was evaluated. Tensile bond strengths of a bonding resin to air-abraded bovine enamel and dentin were measured. Scanning electron microscopy was used to observe (1) air-abraded surfaces, (2) fractured surfaces after the tensile bond test, and (3) interfaces of bonded specimens. Air abrasion with glass beads significantly decreased the bond strengths to enamel and dentin, whereas air abrasion with alumina decreased adhesion to enamel but not to dentin. The air-abraded enamel and dentin surfaces were irregularly roughened, and smear layers were created by air abrasion. Hybrid layers were observed at the interface between the bonding resin and the air-abraded dentin. The SEM photographs suggested that air abrasion may weaken the tooth surfaces, which could account for the decrease of the bond strengths.