ULU Lekholm

U Lekholm

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


U Lekholm has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 4 March 2000
      • Vol. 15  (1) , 103-10

    Influence of bicortical or monocortical anchorage on maxillary implant stability: a 15-year retrospective study of Brånemark System implants.

    by C J Ivanoff, K Gröndahl, C Bergström, U Lekholm, P I Brånemark

    The present study evaluated implant survival and marginal bone loss in maxillae over a 15-year follow-up period as a function of either monocortical or bicortical implant anchorage. Of 207 standard Brånemark implants (10 mm in length) followed, 110 implants were judged to be monocortically anchored and 97 as bicortically anchored. The bicortically anchored implants failed nearly 4 times more often than the monocortical ones. Implant fractures accounted for over 80% of the observed failures and were found to affect the bicortical group almost 3 times more often. As tentative explanations, induction of increased stress and bending forces resulting from possible prosthetic misfit, presence of unfavorable arch relationships, or high occlusal tables in combination with bicortically anchored implants have been suggested, all indicating an overambitious fixation of the bicortical anchorage. Total marginal bone loss was low over the 15-year period and close to identical for the 2 groups, suggesting that the mode of cortical anchorage did not have any clinically significant influence on marginal bone remodeling.


    • 26 October 1999
      • Vol. 14  (5) , 639-45

    Survival of the Brånemark implant in partially edentulous jaws: a 10-year prospective multicenter study.

    by U Lekholm, J Gunne, P Henry, K Higuchi, U Lindén, C Bergström, D Van Steenberghe

    A total of 127 partially edentulous patients, treated according to the Brånemark protocol, was followed for 10 years after completion of prosthetic treatment. The patients ranged in age from 18 to 70 years, and 57% were female. Four hundred sixty-one implants were placed in 56 maxillae and 71 mandibles. In 125 patients, 163 fixed partial prostheses were attached to the implants; a majority of the prostheses (83%) were located in posterior regions. At the end of the 10-year period, 73% of the implants could be traced either as failed or in function, providing cumulative implant survival rates of 90.2% and 93.7% for the maxilla and mandible, respectively. Of the original fixed prostheses, 63% (cumulatively 86.5%) were still in use, whereas the level of continuous cumulative prosthesis function, including primary and remade restorations, was 94.3% at the end of the evaluation period. Marginal bone resorption at the implants was low (mean = 0.7 mm), and mucosal health was good. No severe complications apart from the above-mentioned implant and prosthetic failures were reported. The Brånemark Implant System is a safe and predictable method for restoring partially edentulous patients, as demonstrated by this 10-year follow-up investigation.


    • 23 April 1999
      • Vol. 14  (2) , 173-80

    Influence of variations in implant diameters: a 3- to 5-year retrospective clinical report.

    by C J Ivanoff, K Gröndahl, L Sennerby, C Bergström, U Lekholm

    Sixty-seven patients ranging in age from 16 to 86 years were included in this 3- to 5-year retrospective report focusing on implant survival and marginal bone remodeling in relation to implant diameter. A total of 299 Brånemark implants (3.75-mm diameter: 141; 4.0-mm diameter: 61; 5.0-mm diameter: 97) were placed in 16 completely and 51 partially edentulous arches. Seven of the 141 implants in the 3.75-mm-diameter group failed (5%). The corresponding value for the 4.0-mm-wide implants was 2 of 61 (3%). The highest failure rate, 18% (17/97), was seen for the 5.0-mm-diameter implants. The least favorable cumulative survival rates were seen in mandibles after 5 years and involving 4.0-mm- and 5.0-mm-diameter implants (84.8% and 73.0%, respectively). The marginal bone loss was generally low over the 5-year period. When the data were evaluated by the Cox regression analysis, a relationship was found between implant failure and implant diameter (P < .05), with a higher failure rate for the 5.0-mm-diameter implant. However, no relationship could be seen between implant failure and jaw type, or bone quality and quantity (P > .05). Neither was any relationship seen between marginal bone loss and bone quality and quantity, implant diameter, or jaw type when tested by multiple linear regression analysis (P > .05). A learning curve, poor bone quality, and changed implant design were suggested as possible reasons for the less positive outcome seen for the 5.0-mm-diameter implant. The fact that this implant was often used as a rescue implant when the standard ones were not considered suitable or did not reach initial stability was another plausible explanation.


    • 1 May 1995
      • Vol. 10  (3) , 312-8

    Treatment of fenestration and dehiscence bone defects around oral implants using the guided tissue regeneration technique: a prospective multicenter study.

    by C Dahlin, U Lekholm, W Becker, B Becker, K Higuchi, A Callens, D Van Steenberghe

    Four clinical centers, using the Brånemark System and with personnel trained in the use of Gore-Tex Augmentation Material (GTAM), participated in a prospective study of 45 patients 18 to 83 years of age. A total of 55 implants were placed with membranes because of local bony defects (fenestration or dehiscence). Dehiscence and fenestration defects were evaluated as one group. The mean initial defect height was 4.7 mm (SD = 3.0). After healing, the remaining defect height was reduced to 1.1 mm (SD = 2.3). The decrease in surface exposure was significant. Complications were primarily attributed to exposure of six membranes during the early healing period. The cumulative survival rate was 84.7% in maxillae and 95.0% in mandibles after 2 years of follow-up. The surgical application of GTAM to produce bone in localized bony defects around oral implants seems to be a predictable method that may reduce the need for extensive augmentation surgery in patients with insufficient jaw bone volume.