S Gallego
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
S Gallego has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
E Truy
4 shared publicationsC Berger-Vachon
3 shared publicationsA Morgon
2 shared publicationsL Collet
2 shared publicationsE Ionescu
1 shared publicationF Seldran
1 shared publication
Latest Publications
- 30 June 2008
- Published by Lavoisier in Sciences et Technologies pour le Handicap
- Vol. 2 (1) , 25-39
Réhabilitation de la surdité par la stimulation électrique-acoustique (EAS) : indications pour l'implantation
Réhabilitation de la surdité par la stimulation électrique-acoustique (EAS) : indications pour l'implantation
- 30 June 2008
- Published by Lavoisier in Sciences et Technologies pour le Handicap
- Vol. 2 (1) , 25-39
Réhabilitation de la surdité par la stimulation électrique-acoustique (EAS) : indications pour l'implantation
Réhabilitation de la surdité par la stimulation électrique-acoustique (EAS) : indications pour l'implantation
- 1 January 2002
- Vol. 119 (3) , 150-8
[Binaural cochlear implantation: general concept, surgical technique and electrophysiology].
Cochlear implant have been proven to be safe and cost-effective in deafened adults. Generally, a single cochlear implants is proposed providing monaural audition. Some teams have published interesting results in patients wearing two cochlear implants. The cost of the surgical procedure is greatly increased for bilateral implantation. In an attempt to provide patients with binaural hearing and a better chance to improve their capacity for frequency discrimination without an excessive increase in cost, we developed an new concept and design for binaural cochlear implants. The aim of the present study was to establish the surgical technique for binaural cochlear implantation with a single internal receptor-stimulator. We report descriptive data on surgical procedures performed in two cadavers and in two deafened adults. The special implant is composed of a single receptor-stimulator and two electrode arrays: a short one implanted into the ipsilateral ear and a long one in the contralateral ear. A specially designed tool for endoscopic facial lifting was used to create subcutaneous tunnels from the ipsilateral to the contralateral ear. Insertion into cochleas was unremarkable. Additional time for surgery (compared with mean operative time for routine adult surgery in our unit), and surgical details are discussed. Binaural cochlear implantation is feasible, easy and not very time consuming. Studies are in progress to determine patient benefit. Obtaining auditory brainstem evoked potentials electrically in patients with binaural cochlear implants is possible and provides an interesting mode for in vivo analysis of the long-term effect of profound/total deafness on neural transmission. In our patients, results have demonstrated that neural response properties in auditory pathways are negatively related to duration of deafness.
- 1 January 2002
- Vol. 119 (3) , 150-8
[Binaural cochlear implantation: general concept, surgical technique and electrophysiology].
Cochlear implant have been proven to be safe and cost-effective in deafened adults. Generally, a single cochlear implants is proposed providing monaural audition. Some teams have published interesting results in patients wearing two cochlear implants. The cost of the surgical procedure is greatly increased for bilateral implantation. In an attempt to provide patients with binaural hearing and a better chance to improve their capacity for frequency discrimination without an excessive increase in cost, we developed an new concept and design for binaural cochlear implants. The aim of the present study was to establish the surgical technique for binaural cochlear implantation with a single internal receptor-stimulator. We report descriptive data on surgical procedures performed in two cadavers and in two deafened adults. The special implant is composed of a single receptor-stimulator and two electrode arrays: a short one implanted into the ipsilateral ear and a long one in the contralateral ear. A specially designed tool for endoscopic facial lifting was used to create subcutaneous tunnels from the ipsilateral to the contralateral ear. Insertion into cochleas was unremarkable. Additional time for surgery (compared with mean operative time for routine adult surgery in our unit), and surgical details are discussed. Binaural cochlear implantation is feasible, easy and not very time consuming. Studies are in progress to determine patient benefit. Obtaining auditory brainstem evoked potentials electrically in patients with binaural cochlear implants is possible and provides an interesting mode for in vivo analysis of the long-term effect of profound/total deafness on neural transmission. In our patients, results have demonstrated that neural response properties in auditory pathways are negatively related to duration of deafness.
- 1 January 1999
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 119 (2) , 234-238
Loudness Growth Functions and EABR Characteristics in Digisonic Cochlear Implantees
Electrically evoked auditory brainstem responses (EABRs) and loudness functions were measured in 14 subjects equipped with an MXM Digisonic cochlear implant. EABRs were evoked by 75-Hz pulse trains presented on the apical electrode. Loudness functions at the same rate and at a rate more conventional for psychoacoustic measurements (300 Hz) were measured using a categorical loudness-scaling procedure. The results revealed a significant difference in the loudness functions measured at 75 and 300 Hz, loudness increasing more steeply with stimulus intensity for the latter rate. Significant correlations between EABR wave V thresholds and perceptual thresholds measured at both 75 and 300 Hz were observed. Furthermore, in 8 out of the 14 patients, EABR wave V saturated at a stimulus level corresponding precisely to the loudest bearable, i.e. "Too loud" level for the 300-Hz stimulation rate; this same level corresponded to the "Comfortable" loudness level for the 75-Hz stimulation rate. On average, an almost linear relationship was observed over the first half of the loudness range between the stimulus intensity, expressed as a pulse duration in log units, and wave V amplitude in dB. Although further investigation is required before maximum comfort levels can be predicted reliably from EABR measures in individual subjects, these results indicate new directions regarding the estimation of perceptual dynamic range limits on the basis of EABR measures in cochlear implantees.
- 1 January 1999
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 119 (2) , 234-238
Loudness Growth Functions and EABR Characteristics in Digisonic Cochlear Implantees
Electrically evoked auditory brainstem responses (EABRs) and loudness functions were measured in 14 subjects equipped with an MXM Digisonic cochlear implant. EABRs were evoked by 75-Hz pulse trains presented on the apical electrode. Loudness functions at the same rate and at a rate more conventional for psychoacoustic measurements (300 Hz) were measured using a categorical loudness-scaling procedure. The results revealed a significant difference in the loudness functions measured at 75 and 300 Hz, loudness increasing more steeply with stimulus intensity for the latter rate. Significant correlations between EABR wave V thresholds and perceptual thresholds measured at both 75 and 300 Hz were observed. Furthermore, in 8 out of the 14 patients, EABR wave V saturated at a stimulus level corresponding precisely to the loudest bearable, i.e. "Too loud" level for the 300-Hz stimulation rate; this same level corresponded to the "Comfortable" loudness level for the 75-Hz stimulation rate. On average, an almost linear relationship was observed over the first half of the loudness range between the stimulus intensity, expressed as a pulse duration in log units, and wave V amplitude in dB. Although further investigation is required before maximum comfort levels can be predicted reliably from EABR measures in individual subjects, these results indicate new directions regarding the estimation of perceptual dynamic range limits on the basis of EABR measures in cochlear implantees.
- 1 January 1997
- Vol. 114 (4) , 116-24
[Value of auditory evoked potentials of the brain stem in patients with a Digisonic cochlear implant].
We report our techniques of electrically elicited Auditory Brainstem Responses (eABR) in Digisonic DX 10 cochlear implanted patients and summarize the theoretical interests of objectives measures in pre-, per- and post-operative periods of the cochlear implantation process. This report demonstrates the major interest of eABR during rehabilitation with a cochlear implant. EABR allowed us to detect the lack of device integrity in one electrode in one patient. The quality of electrically elicited responses can contribute to appreciate the electrophysiological responses during electrical stimulation. We found a very strong correlation between the objective thresholds (obtained by means of eABR) and subjective ones (obtained by means of behavioral methods); this is of major interest in the pediatric populations.
- 1 January 1997
- Vol. 114 (4) , 116-24
[Value of auditory evoked potentials of the brain stem in patients with a Digisonic cochlear implant].
We report our techniques of electrically elicited Auditory Brainstem Responses (eABR) in Digisonic DX 10 cochlear implanted patients and summarize the theoretical interests of objectives measures in pre-, per- and post-operative periods of the cochlear implantation process. This report demonstrates the major interest of eABR during rehabilitation with a cochlear implant. EABR allowed us to detect the lack of device integrity in one electrode in one patient. The quality of electrically elicited responses can contribute to appreciate the electrophysiological responses during electrical stimulation. We found a very strong correlation between the objective thresholds (obtained by means of eABR) and subjective ones (obtained by means of behavioral methods); this is of major interest in the pediatric populations.
- 1 September 1995
- Vol. 166, 351-3
Analytic importance of the coding features for the discrimination of vowels in the cochlear implant signal.
The present study considers the analytic importance of the excitation pulse features delivered by a Nucleus cochlear implant using the F0F1F2 strategy. Four cochlear implant patients and 10 speakers uttering two 48-item lists constructed from four basic French vowels participated in this study. Patterns were presented to the patients and played at the input of an acquisition system in order to record the pulse features. Confusion matrices obtained with the patients and with automatic recognition procedures were then compared in order to find out the best-matching models simulating the patients' performances, out of 255 possibilities. The automatic recognition was carried out according to fuzzy logic based on the elementary features of the pulses coding the vowels. Results show that the essential features strongly depended on the subject.
- 1 September 1995
- Vol. 166, 351-3
Analytic importance of the coding features for the discrimination of vowels in the cochlear implant signal.
The present study considers the analytic importance of the excitation pulse features delivered by a Nucleus cochlear implant using the F0F1F2 strategy. Four cochlear implant patients and 10 speakers uttering two 48-item lists constructed from four basic French vowels participated in this study. Patterns were presented to the patients and played at the input of an acquisition system in order to record the pulse features. Confusion matrices obtained with the patients and with automatic recognition procedures were then compared in order to find out the best-matching models simulating the patients' performances, out of 255 possibilities. The automatic recognition was carried out according to fuzzy logic based on the elementary features of the pulses coding the vowels. Results show that the essential features strongly depended on the subject.