FFFang Fang

Fang Fang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fang Fang has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Measurement of Ultra-Low Frequency Vibrations Using an Atom Interferometer

    by Zenghan Ma, Wei Zhuang, Yang Zhao, Chuanjing Ruan, Qin Tian, Jiamin Yao, Jinyang Feng, Shuqing Wu, Fang Fang, Ling Wan

    Measuring low-frequency and ultra-low-frequency vibration signals is of critical importance in fields such as structural mechanics, geological exploration, aerospace, precision machining, and biomedicine. Existing methods face limitations in achieving both ultra-low-frequency range and high precision. We present an ultra-low-frequency vibration measurement method based on the atom interferometer, capable of measuring vibration signals from 0.01 Hz to DC. The performance of measurement was experimentally demonstrated for vibrations between 0.007 Hz and 0.01 Hz, achieving a sensitivity of 1.1 μm/s2/Hz. Incorporating active vibration isolation can further enhance the measurement range, increasing the optimal sensitivity to 0.2 μm/s2/Hz.

  • Open Access

    Uncertainty evaluation of the caesium fountain primary frequency standard NIM6

    by Fasong Zheng, Weiliang Chen, Kun Liu, Shaoyang Dai, Nianfeng Liu, Yuzhuo Wang, Fang Fang

    A new caesium (Cs) fountain clock NIM6 has been developed at the National Institute of Metrology (NIM) in China, for which a comprehensive uncertainty evaluation is presented. A three-dimensional magneto-optical trap loading optical molasses is employed to obtain more cold atoms rapidly and efficiently with a tunable, uniform density distribution. A heat pipe surrounding the flight tube maintains a consistent and stable temperature within the interrogation region. Additionally, a Ramsey cavity with four azimuthally distribution feeds is utilized to mitigate distributed cavity phase shifts. The Cs fountain clock NIM6 achieves a short-term fractional frequency instability of 1.0 × 10 −13 τ −1/2 at high atomic density, and a typical overall fractional type-B uncertainty is estimated to be 2.2 × 10 −16 . Comparisons of frequency between the Cs fountain NIM6 and other Cs fountain primary frequency standards through Coordinated Universal Time have demonstrated an agreement within the stated uncertainties.


  • Open Access

    Uncertainty Evaluation of the Caesium Fountain Primary Frequency Standard NIM6

    by Fasong Zheng, Weiliang Chen, Kun Liu, Shaoyang Dai, Nianfeng Liu, Yuzhuo Wang, Fang Fang

    A new caesium (Cs) fountain clock NIM6 has been developed at the National Institute of Metrology (NIM) in China, for which a comprehensive uncertainty evaluation is presented. A three-dimensional magneto-optical trap (3D MOT) loading optical molasses is employed to obtain more cold atoms rapidly and efficiently with a tunable, uniform density distribution. A heat pipe surrounding the flight tube maintains a consistent and stable temperature within the interrogation region. Additionally, a Ramsey cavity with four azimuthally distribution feeds is utilized to mitigate distributed cavity phase shifts. The Cs fountain clock NIM6 achieves a short-term stability of 1.0x10-13 τ-1/2 at high atomic density, and a typical overall fractional type-B uncertainty is estimated to be 2.3x10-16. Comparisons of frequency between the Cs fountain NIM6 and other Cs fountain Primary Frequency Standards (PFSs) through Coordinated Universal Time (UTC) have demonstrated an agreement within the stated uncertainties.

  • Open Access

    A Transportable Atomic Gravimeter with Constraint-Structured Active Vibration Isolation

    by Chuanjing Ruan, Wei Zhuang, Jiamin Yao, Yang Zhao, Zenghan Ma, Cong Yi, Qin Tian, Shuqing Wu, Fang Fang, Yinghong Wen

    Many efforts have been taken in recent years to push atomic gravimeters toward practical applications. We demonstrate an atomic gravimeter named NIM-AGRb2 that is transportable and suitable for high-precision gravity measurements. Constraint-structured active vibration isolation (CS-AVI) is used to reduce the ground vibration noise. The constraint structure in CS-AVI ensures that the isolation platform only has vertical translation, with all other degrees of freedom (DoFs) being constrained. Therefore, the stability of active vibration isolation is enhanced. With the implementation of CS-AVI, the sensitivity of NIM-AGRb2 reached as low as 20.5 μGal/Hz1/2. The short-term sensitivity could be further reduced to 10.8 μGal/Hz1/2 in a seismologic observation station. Moreover, we evaluated the system noise of the gravimeter, and the results were consistent with our observations.


  • Open Access

    Development and Evaluation of a Narrow Linewidth Laser System for 171Yb+ E2 Transition

    by Yani Zuo, Shiying Cao, Shaoyang Dai, Yige Lin, Tao Yang, Baike Lin, Fei Meng, Weiliang Chen, Kun Liu, Fasong Zheng, et al.

    We report the construction and characterization of a narrow-linewidth laser system to interrogate the E2 clock transitions at 436 nm of ytterbium ions trapped in end-cap traps. The 871 nm seed laser at the fundamental frequency is referenced to a 10 cm long notched ULE cavity. The output of the laser system is delivered to a narrow-linewidth femtosecond fiber comb, which has been referenced to an ultrastable 698 nm laser, with a phase noise-canceled fiber link. The beat between the laser and the comb shows a sub-Hz linewidth, and with a stability better than 2E-15@1~100 s. The performance of the self-developed wavelength extension ports at 871 nm of the narrow linewidth erbium-doped fiber comb with single-point frequency-doubling technique is also verified.

  • Bimetal Temperature-Compensated Ramsey Cavity for Atomic Fountain Frequency Standards

    by Fasong Zheng, Fang Fang, Weiliang Chen, Kun Liu, Shaoyang Dai, Shiying Cao, Yani Zuo, Tianchu Li

    A typical Ramsey cavity, commonly used in atomic fountain frequency standards (AFFSs) for microwave interrogation, is sensitive to ambient temperature variation. Then, it becomes one of the main limiting factors for the AFFSs operating in a narrow operating-temperature range and a temperature-well-controlled environment up to now. In this article, a new design of bimetal temperature-compensated Ramsey cavity (BTCRC) based on the thermal expansion self-compensating mechanism is presented and experimentally demonstrated. This cavity is a typical TE $_{011}$ -mode cylindrical microwave resonator with a titanium tube and two oxygen-free copper (OFC) caps. The resonance frequency (RF) of the cavity can be immune to temperature variations if the dimensions of the tube and caps are properly designed. To validate this self-compensating mechanism, a BTCRC resonating at the Rb clock frequency with a $Q$ -factor of about 17 000 is constructed. And its RF thermal coefficient is measured to be 0.73 kHz/ $^{\circ}$ C, which is about 150 times superior to $-$ 115.9 kHz/ $^{\circ}$ C of a typical OFC Rb cavity in the temperature range of 22.48 $^{\circ}$ C–37.48 $^{\circ}$ C. During the operation of AFFSs, this BTCRC ensures that the microwave field amplitude inside the cavity, which dictates the transition probability and thus the contrast of the Ramsey fringes, will be stable in time. In addition, the potential temperature variation-induced frequency shifts due to cavity pulling are significantly minimized.


  • Open Access

    Development of Rb fountain clock for time keeping

    by Chen Weiliang, Fang Fang, Liu Kun, Zheng Fasong, Dai Shaoyang, Zuo Yani, Li Tianchu

    A new Rb fountain clock was built at the National Institute of Metrology with the aim to realize robustness and excellent long-term instability for time keeping. While some basic designs have been adopted from our Cs fountain clocks, new features have been included for improved performance. A double-metal interrogation microwave cavity with a thermal expansion self-compensating mechanism was used to reduce the clock sensitivity to temperature fluctuations for the first time, to our knowledge. Moreover, a compact optical system was developed to ensure robustness. These features dramatically increased the ambient temperature range. The developed Rb fountain clock achieved a typical fractional frequency instability of 1.49×10−13(τ/s)−1/2within 10 days of continuous operation without any intervention, demonstrating the potential for time keeping.


  • A Low Temperature-Sensitive Ramsey Cavity for Rb Fountain Clocks

    by Fasong Zheng, Fang Fang, Xiumei Wang, Weiliang Chen, Kun Liu, Shaoyang Dai, Shiying Cao, Yani Zuo, Tianchu Li


  • Improvement of the short-term stability of atomic fountain clock with state preparation by two-laser optical pumping*

    by Lei Han, Fang Fang, Wei-Liang Chen, Kun Liu, Shao-Yang Dai, Ya-Ni Zuo, Tian-Chu Li

    To improve the signal to noise ratio (SNR) and the short-term stability of cesium atomic fountain clocks, the work of two-laser optical pumping is presented theoretically and experimentally. The short-term stability of the NIM6 fountain clock has been improved by preparing more cold atoms in the | F = 4, mF = 0〉 clock state with a shortened cycle time. Two π-polarized laser beams overlapped in the horizontal plane have been applied after launching, one is resonant with | F = 4〉 → | F′ = 4〉 transition and the other is resonant with | F = 3〉 → | F′ = 4〉 transition. With optical pumping, the population accumulated in the | mF = 0〉 clock state is improved from 11% to 63%, and the detection signal is increased by a factor of 4.2, the SNR of the clock transition probability and the short-term stability are also improved accordingly.


  • Cold atom clocks and their applications in precision measurements*

    by Shao-Yang Dai, Fa-Song Zheng, Kun Liu, Wei-Liang Chen, Yi-Ge Lin, Tian-Chu Li, Fang Fang

    Cold atom clocks have made remarkable progresses in the last two decades and played critical roles in precision measurements. Primary Cs fountain frequency standards have achieved a total uncertainty of a few parts in 1016, and the best optical clock has reached a type B uncertainty below 10−18. Besides applications in the metrology, navigation, etc., ultra-stable and ultra-accurate atomic clocks have also become powerful tools in the basic scientific investigations. In this paper, we focus on the recent developments in the high-performance cold atomic clocks which can be used as frequency standards to calibrate atomic time scales. The basic principles, performances, and limitations of fountain clocks and optical clocks based on signal trapped ion or neutral atoms are summarized. Their applications in metrology and other areas are briefly introduced.