  • Comprehensive diagnostics of DC interruption process of pure-water arc discharge under high-pressure conditions

    by Kai Yokouchi, Naoto Kodama, Sota Nonoyama, Yasunobu Yokomizu, Yasushi Yamano, Yuki Inada

    In recent years, the demand for direct-current (DC) power supply systems has increased with the widespread adoption of electric vehicles and renewable energy, leading to a growing need for low-cost, highly reliable DC protection devices. A power fuse is a widely accepted choice as a DC protection device; however, conventional arc-quenching media inside the fuse, such as silica sand, exhibit a significant reduction in current-limiting ability in the low-current region, resulting in degraded interruption reliability. In this study, pure water is employed as a new arc-quenching medium to maintain current-limiting performance in the low-current region. Its effectiveness is verified through DC 100 V interruption tests.

  • Open Access

    Optimization-Based Cost-Frequency Trade-Off Analysis of Active Power Reallocation in Bipolar MTDC Systems

    by Ayaka Nakamura, Mikimasa Iwata, Yasunobu Yokomizu, Naoto Kodama, Takuto Ohsawa

    In multi-terminal DC (MTDC) systems, converter outages require immediate active power reallocation among healthy converters to maintain the stability of interconnected AC grids. While previous studies mainly focused on control strategies for DC power flow, the economic implications for AC systems including operational costs and frequency stability impacts remain insufficiently addressed. This study proposes an optimization framework to simultaneously minimize the total adjustment cost and frequency deviation by determining optimal active power reallocation among converter stations. The proposed model incorporates multiple types of balancing reserves characterized by distinct cost structures and activation conditions. A four-terminal bipolar VSC-MTDC system is simulated during a converter trip scenario, and the impact of active power reallocation is evaluated in terms of system stability and adjustment cost. By varying the cost-weighting factor, a Pareto front is obtained with three representative operating points: cost-minimization,compromise, and frequency-minimization cases, yielding total adjustment costs of 5.524-5.973 million JPY and cumulative frequency deviations across all interconnected AC systems of 10.125-10.884 Hz. Compared with a baseline scenario without optimization, the proposed framework achieves 20.7-26.7% cost reduction and 26.1-31.3% frequency improvement. The results show that the system operator can select the operation point of the MTDC system based on the specific priorities and system conditions.

  • Improving the Practicality of Innovative DC Circuit Breakers Using Linear Motors

    by Reon Sasaki, Wataru Ohnishi, Naoto Kodama, Yusuke Nakano, Shungo Zen, Yasushi Yamano, Yuki Inada

  • Experimental comparison of arc resistance and current limiting rate in low-current phase between SiO2-sand and pure water in DC electric fuse

    by Taihei Kobayashi, Naoto Kodama, Sota Nonoyama, Yasunobu Yokomizu, Yuki Inada

    The present paper carried out the direct-current(DC) arc quenching experiment using the SiO2-sand, which is conventional DC arc quenching medium. Based on the experiment, we experimentally clarified that the drawback of the SiO2-sand was cheap current limiting rate |di/dt| at low current phase. Therefore, through theoretical calculation of gas properties, we selected pure-water(H2O) as novel arc quenching medium that can overcome the drawback of the SiO2-sand. Then, we conducted DC arc quenching experiment using H2O under 1.3 kA/100 V condition. As an experimental result, the H2O utilization successfully increased |di/dt| at low current phase. For instance, |di/dt| under the H2O condition was 1000 A/ms, which was higher than 200 A/ms under the SiO2-sand condition. This high |di/dt| under the H2O condition arises from high arc resistance at low current phase. The present result is convenient to improve DC interruption performance of the electric fuses.


  • Open Access

    Proposal of Emergency Operation and Active Power Dispatch Control Scheme for Bipolar VSC-MTDC System

    by Ayaka Nakamura, Mikimasa Iwata, Yasunobu Yokomizu, Naoto Kodama

    In a bipolar voltage source converter-based multi-terminal DC (VSC-MTDC) system, the power flow of the positive and negative pole networks can be controlled independently. This advantage allows bipolar systems to maintain operation with only the healthy pole even in the event of DC faults. However, existing power flow control methods for bipolar systems do not include the optimal mode-switching of each converter’s operation and may not be sufficiently reliable during fault conditions. Thus, this paper proposes a new control scheme considering coordination between the poles and flexibility in power shifting. The proposed method consists of two steps: (a) a mode-switching method of converters to maintain DC voltage stability during converter trips and (b) an active power dispatch control method to enable power shifting from the faulty pole to the healthy pole, mitigating the risk of power surplus and ensuring a robust response to AC grid stability issues. The power assurance coefficient $\omega _{ass,i}^{m}$ is defined as critical factor for determining the interpolar power dispatch. The simulation results show that an average transmission power outage of approximately 220 MW can be prevented during a single-pole trip while maintaining the operation within the rated VSC capacity when $\omega _{ass,i}^{m}$ is set to 0.5. This highlights the effectiveness of the proposed method in maintaining the system reliability and stability. Overall, the proposed method enhances the transmission capability by maintaining the operation within the rated capacity, enabling interpolar power shifting, and mitigating the AC grid instability during fault conditions regardless of the bipolar configuration.


  • Open Access

    Additive effect of silicone resin on direct current arc quenching performance of a model electric fuse: electrical resistivity and thermal diffusivity of high-temperature Cu/SiO2 vapor mixed with C2H6SiO vapor decomposition

    by Waku Takenaka, Naoto Kodama, Yasunobu Yokomizu, Kaito Hasegawa, Kanata Nakamura, Mikimasa Iwata

    Concerning DC fuses equipped with silica sand (SiO2) as an arc quenching material, the authors have proposed an additive installation of silicone resin (C2H6SiO) on a fuse-element surface to improve the limitation and interruption ability of high DC. This paper describes the additive effect of the silicone resin on the transient resistance of the arc that has formed during the DC interrupting process in a model fuse, based on the measurement result that the arc resistance markedly rises with the silicone mass coated on the fuse element. This phenomenon is subsequently explained as resulting from a thermal diffusivity of high-temperature C2H6SiO/SiO2/Cu vapor. In other words, the mixing of C2H6SiO decomposition vapor into the arc can promote vapor temperature decay through the higher thermal diffusivity, resulting in a rapid increase in the electrical resistivity of the vapor during the DC interrupting process.

  • Fault and Load Current Interruption in Low-Voltage System Using Fuse-Semiconductor Current-Limiting Circuit Breaker

    by Yuki Inada, Shungo Zen, Wataru Ohnishi, Naoto Kodama, Yusuke Nakano, Yasuhiro Takada, Reon Sasaki, Yuta Miyaoka, Kosuke Tsukamoto, Keiya Yamada, et al.

    For the realization of carbon neutrality and an advanced information society, we have previously developed a novel current-limiting circuit breaker composed of a fuse, a power semiconductor and a fuse exchanger. However, its feasibility has been confirmed only for fault current interruption in a low voltage range of 100-500V. In this paper, the current-limiting circuit breaker was successfully used for fault and load current interruption at DC 1.5kV, thus demonstrating the high versatility of the circuit breaker.


  • A mixture of Si3N4 powder and SiO2 sand as a novel DC arc quenching medium for improvement of the current-limiting performance of a model electric fuse

    by Naoto Kodama, Yasunobu Yokomizu, Waku Takenaka

    A current-limiting and consequent direct current (DC) arc interruption requires an increase in arc resistance r a r c for a DC fuse. Flattery silica (SiO2) sand has been used as an arc quenching medium in fuses for decades. However, there are few reports about a novel arc quenching medium which enables more r a r c increases compared to flattery SiO2 sand. This paper uniquely selected a novel arc quenching medium based on the following material properties: (1) electrical resistivity and thermal conductivity in the solid phase, (2) the possibility of r a r c increasing in the gas phase, (3) the possibility of electrical insulation after re-solidification, and (4) the cost of materials. As a result, we originally selected a powder mixture of silicon-nitride (Si3N4) and flattery SiO2 sand as a promising novel arc quenching medium. Therefore, DC interruption experiments were performed using a Si3N4/flattery SiO2 sand powder mixture under different Si3N4 concentration conditions. As a result of 1000 A DC arc quenching experiments, the utilization of Si3N4 powder with the flattery SiO2 sand successfully increased the arc resistance r a r c during the arc quenching process. The increasing Si3N4 concentration exhibited a further increase in r a r c during the arc quenching process. As a result of the r a r c increase, the arc quenching time was significantly shortened to 30 ms for 30 wt.% Si3N4 conditions from 54 ms for the SiO2 sand conditions. In addition, utilization of Si3N4 powder achieved high insulation resistance over few MΩ after DC arc interruption. The above results clearly indicate that utilization of Si3N4 powder with flattery SiO2 sand can increase the DC interruption performance of the fuse.

  • High-temperature properties of dry air used as arc quenching medium and its mixture with vaporized C 2 F 4 : reaction products and critical reduced electric field strength at 300–3000 K

    by Y Yokomizu, N Kodama, I Yamamoto, S Uchiyama, M Sato, Y Nakamura, T Edo

    Recently, electric power equipment manufacturers released a joint statement with the aim of developing high-voltage electrical equipment completely free of fluorinated gases such as fluoroketones and fluoronitriles, which are considered as alternatives to S F 6 and artificially produced compounds of F. This paper considers air as a typical gas present naturally in the environment to investigate its high-temperature properties, including an air mixture with C 2 F 4 vapor injected from a polytetrafluoroethylene nozzle, for application as an arc-quenching medium in a high-voltage circuit breaker equipped with a nozzle. Chemical composition results for the reaction products at 300–3000 K show that the admixture of C 2 F 4 vapor causes a decrease in the molar number of O 2 contained in the air, owing to the production of O-containing compounds such as C O 2 and C O . Additionally, the results reveal that the admixture of C 2 F 4 vapor lead to the production of C F 4 as the predominant F-containing compound. Furthermore, the boundary condition for O 2 production in terms of O 2 molar number X O 2 and C 2 F 4 molar number X C 2 F 4 is formulated. Such evaluation of the mixture composition enables the determination of a reduced effective collision ionization coefficient α ˉ / N and a critical reduced electric field strength E c r / N , resulting in α ˉ / N = 0. The strength E c r / N for the mixture with 30%–100% C 2 F 4 molar fraction rises to approximately 150 Td (1 Td = 1 × 10 − 21 V m2) over 300–3000 K, which is 20–50 Td higher than that for high-temperature air unmixed with C 2 F 4 vapor. The variation in E c r / N is discussed in terms of predominant electron impact processes and the electron energy distribution function in the mixture.


  • Spatiotemporal evolution of electrical conductivity in current-limiting-fuse arc

    by Yuki Inada, Yusuke Fukai, Naoki Takayasu, Yusuke Nakano, Shungo Zen, Wataru Ohnishi, Yasushi Yamano, Mitsuaki Maeyama, Naoto Kodama

    To improve the interruption capacity of a current-limiting fuse, a detailed diagnosis of the spatial electrical conductivity distribution inside the fuse arc under the current limiting phase around current zero is required, because this distribution determines the distribution of transient recovery voltage inside the fuse. However, well-established methodologies applicable to fuse arcs are lacking, so the spatial distribution remains unknown. This study presents a borescope-integrated spectroscopic system that simultaneously obtains single-shot recordings of the axial distributions of the electron density and arc temperature in the fuse arc just before extinction. Combining the electron densities and arc temperatures, we can identify the fuse arc composition and hence calculate the axial electrical conductivity distribution under the first Chapman–Enskog approximation. The electrical conductivity provided by this systematic methodology includes no large uncertainties, thus demonstrating its superiority against previous estimation methods of the electrical conductivity.