Raymond R. Raylman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Raymond R. Raylman has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
R L Wahl
5 shared publicationsAnaira C. Clavo
Department of Internal Medicine, Division of Nuclear Medicine, University of Michigan Medical Center, Ann Arbor, MI, USA
1 shared publicationBetty Recker
Department of Internal Medicine, Division of Nuclear Medicine, University of Michigan Medical Center, Ann Arbor, MI, USA
1 shared publicationE P Ficaro
1 shared publicationR S Brown
1 shared publicationRichard L. Wahl
Department of Radiology, University of Michigan Medical Center, Ann Arbor, MI, USA
1 shared publication
Latest Publications
- 1 March 1997
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 37 (5) , 1201-1206
Magnetically-enhanced radionuclide therapy (MERiT): In vitro evaluation
- 1 March 1997
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 37 (5) , 1201-1206
Magnetically-enhanced radionuclide therapy (MERiT): In vitro evaluation
- 1 November 1996
- Vol. 37 (11) , 1914-5
Don't forget MERiT.
- 1 September 1996
- Vol. 37 (9) , 1562-7
Stereotactic coordinates from ECT sinograms for radionuclide-guided breast biopsy.
Raw data from emission scanners contained in ECT sinograms can provide an abundance of information about the position of an object in the camera's field-of-view. Since some cancers can be detected by PET and SPECT which are not seen clearly on mammograms, CT or other scans, sinogram data could potentially be used to guide tumor biopsy. For example, positron-emitting (18F-labeled Fluoro-deoxyglucose) and single-photon emitting (99mTc-labeled-sestamibi) radiopharmaceuticals have been used successfully to detect many types of breast cancer. By utilizing some relatively simple geometric relationships, a sinogram-based method for biopsy of radiopharmaceutical-avid breast masses guided by data from PET and SPECT scanners has been developed and validated in phantom studies. A pair of projection views from a series of sinograms is used to calculate the position of photon-emitting objects. Calculated positions of spheres ranging in size from 1.6 to 3.4 cm diameters containing 18F and 99mTc were compared with measured positions. By adding a single radioactive fiducial marker, emission-guided biopsy of simulated breast lesions was performed with a specially designed phantom containing photon-emitting spheres 12.7 mm in diameter. Correlation between calculated and measured object coordinates were excellent (R = 1.0, R = 1.0 and R = 0.998; x, y and z coordinates, respectively). The maximum error in localization was +/- 3 mm. One hundred percent (10 of 10) of the attempted biopsies of simulated tumors were successful. A method for rapidly determining the position of photon-emitting objects in an emission scanner has been developed and tested. This technique, which does not require standard emission or anatomic images, could be used with dedicated biopsy machines or incorporated into "add-on" biopsy devices for existing PET or SPECT cameras.
- 1 September 1996
- Vol. 37 (9) , 1562-7
Stereotactic coordinates from ECT sinograms for radionuclide-guided breast biopsy.
Raw data from emission scanners contained in ECT sinograms can provide an abundance of information about the position of an object in the camera's field-of-view. Since some cancers can be detected by PET and SPECT which are not seen clearly on mammograms, CT or other scans, sinogram data could potentially be used to guide tumor biopsy. For example, positron-emitting (18F-labeled Fluoro-deoxyglucose) and single-photon emitting (99mTc-labeled-sestamibi) radiopharmaceuticals have been used successfully to detect many types of breast cancer. By utilizing some relatively simple geometric relationships, a sinogram-based method for biopsy of radiopharmaceutical-avid breast masses guided by data from PET and SPECT scanners has been developed and validated in phantom studies. A pair of projection views from a series of sinograms is used to calculate the position of photon-emitting objects. Calculated positions of spheres ranging in size from 1.6 to 3.4 cm diameters containing 18F and 99mTc were compared with measured positions. By adding a single radioactive fiducial marker, emission-guided biopsy of simulated breast lesions was performed with a specially designed phantom containing photon-emitting spheres 12.7 mm in diameter. Correlation between calculated and measured object coordinates were excellent (R = 1.0, R = 1.0 and R = 0.998; x, y and z coordinates, respectively). The maximum error in localization was +/- 3 mm. One hundred percent (10 of 10) of the attempted biopsies of simulated tumors were successful. A method for rapidly determining the position of photon-emitting objects in an emission scanner has been developed and tested. This technique, which does not require standard emission or anatomic images, could be used with dedicated biopsy machines or incorporated into "add-on" biopsy devices for existing PET or SPECT cameras.
- 1 October 1995
- Vol. 36 (10) , 1869-74
Fluorine-18-fluorodeoxyglucose-guided breast cancer surgery with a positron-sensitive probe: validation in preclinical studies.
In this study, the feasibility of utilizing 2-deoxy-2-fluoro-d-glucose (FDG) in conjunction with a positron-sensitive intraoperative probe to guide breast tumor excision was investigated. The probe was constructed with a plastic scintillator tip coupled to a photomultiplier tube with fiber optic cable. Anticipated resolution degradation was evaluated by measurement of line spread functions in the presence of background radiation. Realistic photon background distributions were simulated with a human torso phantom and a cardiac insert. The relationship between resolution and energy threshold was measured to find the optimal discriminator settings. In addition, probe sensitivity as a function of energy threshold was determined for various size-simulated tumors. Finally, the ability to localize breast cancers in vivo was tested in a rodent model. Mammary rat tumors implanted in Lewis rats were examined after injection with FDG; these results were correlated with those of histologic analyses. Measurements of line spread functions indicated that resolution could be maximized in a realistic background photon environment by increasing the energy threshold to levels at or above the Compton continuum edge (340 keV). At this setting, the probe's sensitivity was determined to be 58 and 11 cps/muCi for 3.18- and 6.35-mm diameter simulated tumors, respectively. Probe readings correlated well with histologic results: the probe was generally able to discriminate between tumor and normal tissue. This study indicates that breast cancer surgery guided by a positron-sensitive probe warrants future evaluation in breast-conserving surgery of patients with breast cancer.
- 1 October 1995
- Vol. 36 (10) , 1869-74
Fluorine-18-fluorodeoxyglucose-guided breast cancer surgery with a positron-sensitive probe: validation in preclinical studies.
In this study, the feasibility of utilizing 2-deoxy-2-fluoro-d-glucose (FDG) in conjunction with a positron-sensitive intraoperative probe to guide breast tumor excision was investigated. The probe was constructed with a plastic scintillator tip coupled to a photomultiplier tube with fiber optic cable. Anticipated resolution degradation was evaluated by measurement of line spread functions in the presence of background radiation. Realistic photon background distributions were simulated with a human torso phantom and a cardiac insert. The relationship between resolution and energy threshold was measured to find the optimal discriminator settings. In addition, probe sensitivity as a function of energy threshold was determined for various size-simulated tumors. Finally, the ability to localize breast cancers in vivo was tested in a rodent model. Mammary rat tumors implanted in Lewis rats were examined after injection with FDG; these results were correlated with those of histologic analyses. Measurements of line spread functions indicated that resolution could be maximized in a realistic background photon environment by increasing the energy threshold to levels at or above the Compton continuum edge (340 keV). At this setting, the probe's sensitivity was determined to be 58 and 11 cps/muCi for 3.18- and 6.35-mm diameter simulated tumors, respectively. Probe readings correlated well with histologic results: the probe was generally able to discriminate between tumor and normal tissue. This study indicates that breast cancer surgery guided by a positron-sensitive probe warrants future evaluation in breast-conserving surgery of patients with breast cancer.
- 1 May 1994
- Vol. 35 (5) , 909-13
A fiber-optically coupled positron-sensitive surgical probe.
Positron-emitting radiopharmaceuticals such as 18F-labeled 2-deoxy-D-glucose (FDG) have considerable utility in the noninvasive imaging of cancers due to their rapid and excellent tumor-localizing properties. In addition, the relatively short range of positions in tissue facilitates the precise delineation of FDG-avid tumors. Therefore, FDG used in conjunction with a positron-sensitive probe may be capable of guiding surgical procedures. Many of the current probe systems, however, are sensitive to the intense flux of background photons produced by positron annihilation. We describe the design, manufacture and initial in vitro and in vivo testing of a probe well-suited to the detection of positron-emitting isotopes in a high-photon background. The device consists of a small piece of plastic scintillator coupled by fiber-optic cable to a photomultiplier tube. Measurements of resolution and detector sensitivity were obtained. In addition, the reduction in resolution caused by the effects of various levels of background photon flux was determined. These measurements indicate that resolution is degraded minimally (approximately 5% with a background-to-source ratio of 2:1) due to annihilation photon background. Sensitivity for positrons is good, detecting amounts of radioactivity as low as 10.2 nCi of FDG in vitro. In rats given FDG subcutaneously, lymph nodes containing as little as 11 nCi of FDG could be detected above the background activity levels present in normal surrounding tissues. A plastic scintillator probe system has been devised which may be highly suitable for intraoperative FDG-guided (or other positron or beta emitting-tracer) surgery.
- 1 May 1994
- Vol. 35 (5) , 909-13
A fiber-optically coupled positron-sensitive surgical probe.
Positron-emitting radiopharmaceuticals such as 18F-labeled 2-deoxy-D-glucose (FDG) have considerable utility in the noninvasive imaging of cancers due to their rapid and excellent tumor-localizing properties. In addition, the relatively short range of positions in tissue facilitates the precise delineation of FDG-avid tumors. Therefore, FDG used in conjunction with a positron-sensitive probe may be capable of guiding surgical procedures. Many of the current probe systems, however, are sensitive to the intense flux of background photons produced by positron annihilation. We describe the design, manufacture and initial in vitro and in vivo testing of a probe well-suited to the detection of positron-emitting isotopes in a high-photon background. The device consists of a small piece of plastic scintillator coupled by fiber-optic cable to a photomultiplier tube. Measurements of resolution and detector sensitivity were obtained. In addition, the reduction in resolution caused by the effects of various levels of background photon flux was determined. These measurements indicate that resolution is degraded minimally (approximately 5% with a background-to-source ratio of 2:1) due to annihilation photon background. Sensitivity for positrons is good, detecting amounts of radioactivity as low as 10.2 nCi of FDG in vitro. In rats given FDG subcutaneously, lymph nodes containing as little as 11 nCi of FDG could be detected above the background activity levels present in normal surrounding tissues. A plastic scintillator probe system has been devised which may be highly suitable for intraoperative FDG-guided (or other positron or beta emitting-tracer) surgery.
- 1 January 1994
- Vol. 35 (1) , 157-63
Magnetically enhanced radionuclide therapy.
Radiopharmaceutical therapy is an increasingly common treatment for cancer. This therapy involves the injection of radiolabeled tumor-specific agents into the patient with subsequent preferential accumulation in the tumor sites. Particulate radiation (usually beta particles) emitted by the radioisotope kill or damage the tumor cells. The effectiveness of radiopharmaceutical therapy, however, is limited by the size of the tumor treated. Energetic particles can easily exist small tumors before they are able to deposit their energy and inflict significant damage. We propose the use of a static magnetic field to be applied after the radiopharmaceutical has localized in the tumors, constraining these particles to helical paths. This application would result in substantially confining the emitted particles within the tumor's boundaries, thus increasing radiation dose to the tumor. Computer simulations of radionuclide treatments using 131I, 186Re and 90Y show that a magnetic field of 10 Tesla can increase the radiation dose achieved by conventional radionuclide therapy by up to 71%. In addition, total radiation dose to surrounding normal tissues is substantially reduced. Magnetically enhanced radionuclide therapy (MERiT) therefore shows promise as an effective treatment of cancer and warrants further study.
- 1 January 1994
- Vol. 35 (1) , 157-63
Magnetically enhanced radionuclide therapy.
Radiopharmaceutical therapy is an increasingly common treatment for cancer. This therapy involves the injection of radiolabeled tumor-specific agents into the patient with subsequent preferential accumulation in the tumor sites. Particulate radiation (usually beta particles) emitted by the radioisotope kill or damage the tumor cells. The effectiveness of radiopharmaceutical therapy, however, is limited by the size of the tumor treated. Energetic particles can easily exist small tumors before they are able to deposit their energy and inflict significant damage. We propose the use of a static magnetic field to be applied after the radiopharmaceutical has localized in the tumors, constraining these particles to helical paths. This application would result in substantially confining the emitted particles within the tumor's boundaries, thus increasing radiation dose to the tumor. Computer simulations of radionuclide treatments using 131I, 186Re and 90Y show that a magnetic field of 10 Tesla can increase the radiation dose achieved by conventional radionuclide therapy by up to 71%. In addition, total radiation dose to surrounding normal tissues is substantially reduced. Magnetically enhanced radionuclide therapy (MERiT) therefore shows promise as an effective treatment of cancer and warrants further study.