Ki-Sik Tae
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ki-Sik Tae has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Hyun-Ju Lee
Department of Physical Therapy, Konyang University, Daejeon 35365, Republic of Korea
4 shared publications Hui-Gyeong Gong
Department of Biomedical Engineering, Konyang University, Daejeon, Republic of Korea
3 shared publicationsHyun-Ju Lee
Department of Physical Therapy, Konyang University, Daejeon, Republic of Korea
2 shared publicationsA. Yoon Kim
Department of Orthopedic Surgery, Konyang University Hospital, Daejeon, Republic of Korea
1 shared publication- Bo Sun Kang
Department of Radiological Science, Konyang University, Daejeon 35365, Republic of Korea
1 shared publication - Byung Hak Oh
Department of Orthopedic Surgery, Konyang University College of Medicine, Daejeon 35365, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 14 August 2026
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 27 (1)
A novel stiffness-distribution-controlled hybrid locking compression plate for osteoporotic midshaft clavicle fractures: a finite element study
Background: Fixation of osteoporotic midshaft clavicle fractures in elderly patients requires a careful balance between mechanical integrity and anatomical compatibility. Conventional single-diameter locking plate systems present an inherent trade-off, as larger plates provide robust fixation but often cause soft tissue irritation, whereas low-profile plates often lack the mechanical integrity in osteoporotic bone. This study aimed to biomechanically evaluate a stiffness-distribution–controlled hybrid locking compression plate (Hybrid LCP) designed to mitigate this trade-off using a patient-derived finite element analysis. Methods: A three-dimensional finite element model of a clavicle was reconstructed from CT data of a 73-year-old female, incorporating severe osteoporotic cortical thinning (1.0 mm). A Hybrid LCP combining a 3.5-mm central segment with 2.7-mm lateral segments was compared with conventional 3.5-mm and 2.7-mm plates under cantilever bending, axial compression, and axial torsion. Plate stress and peak cortical and cancellous bone stress-strain responses were evaluated to assess structural integrity and the risk of localized bone failure. Results: Cantilever bending produced the highest stress levels among all loading scenarios. Under this condition, the maximum von Mises stress in the Hybrid LCP (453.4 MPa) was lower than those of the 2.7-mm systems and the conventional 3.5-mm plate (629.5 MPa), indicating a more favorable plate stress distribution. Also, the Hybrid LCP exhibited 50.4% lower peak cancellous bone strain than the conventional curved 2.7-mm plate (6,300 µε vs. 12,700 µε). Conclusion: Under the standardized computational conditions evaluated in this study, the stiffness-distribution–controlled Hybrid LCP reduced stress concentrations associated with low-profile plates and decreased peak cancellous bone strain compared with the curved 2.7-mm plate. These findings suggest that targeted stiffness modulation may provide a promising biomechanical design approach for osteoporotic midshaft clavicle fixation. Further experimental and clinical validation is required before its clinical applicability can be established.
- 14 August 2026
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 27 (1)
Open AccessA novel stiffness-distribution-controlled hybrid locking compression plate for osteoporotic midshaft clavicle fractures: a finite element study
Background: Fixation of osteoporotic midshaft clavicle fractures in elderly patients requires a careful balance between mechanical integrity and anatomical compatibility. Conventional single-diameter locking plate systems present an inherent trade-off, as larger plates provide robust fixation but often cause soft tissue irritation, whereas low-profile plates often lack the mechanical integrity in osteoporotic bone. This study aimed to biomechanically evaluate a stiffness-distribution–controlled hybrid locking compression plate (Hybrid LCP) designed to mitigate this trade-off using a patient-derived finite element analysis. Methods: A three-dimensional finite element model of a clavicle was reconstructed from CT data of a 73-year-old female, incorporating severe osteoporotic cortical thinning (1.0 mm). A Hybrid LCP combining a 3.5-mm central segment with 2.7-mm lateral segments was compared with conventional 3.5-mm and 2.7-mm plates under cantilever bending, axial compression, and axial torsion. Plate stress and peak cortical and cancellous bone stress-strain responses were evaluated to assess structural integrity and the risk of localized bone failure. Results: Cantilever bending produced the highest stress levels among all loading scenarios. Under this condition, the maximum von Mises stress in the Hybrid LCP (453.4 MPa) was lower than those of the 2.7-mm systems and the conventional 3.5-mm plate (629.5 MPa), indicating a more favorable plate stress distribution. Also, the Hybrid LCP exhibited 50.4% lower peak cancellous bone strain than the conventional curved 2.7-mm plate (6,300 µε vs. 12,700 µε). Conclusion: Under the standardized computational conditions evaluated in this study, the stiffness-distribution–controlled Hybrid LCP reduced stress concentrations associated with low-profile plates and decreased peak cancellous bone strain compared with the curved 2.7-mm plate. These findings suggest that targeted stiffness modulation may provide a promising biomechanical design approach for osteoporotic midshaft clavicle fixation. Further experimental and clinical validation is required before its clinical applicability can be established.
- Open Access
- 8 June 2026
- Published by MDPI AG in Healthcare
- Vol. 14 (12) , 1606
Multimodal Validation of an sEMG-Based Visual Biofeedback System for Deep Abdominal Muscle Activation in Healthy Adults: A Randomized Controlled Proof-of-Concept Trial
Background: Portable biofeedback technologies are increasingly used in rehabilitation; however, the validity of surface electromyography (sEMG) as a surrogate indicator of deep abdominal muscle function remains unclear. This study aimed to validate a portable sEMG-based visual biofeedback system by examining its relationship with ultrasound-derived measures of deep abdominal muscle activation. Methods: Twenty-nine healthy adults were randomly assigned to a Visual Biofeedback group (n = 14) or a Verbal Feedback group (n = 15). Both groups performed a standardized 2-week core stabilization program. Muscle activation of the deep abdominal muscle complex (transversus abdominis–internal oblique; TrA–IO) and external oblique (EO) was measured using sEMG (%MVIC), while ultrasound imaging was used to assess transversus abdominis thickness and contractile activity (ADIM–Rest index). Between-group differences and correlations between EMG and ultrasound variables were analyzed. Results: The Visual Biofeedback group demonstrated significantly greater improvements in TrA–IO activation and in the preferential activation ratio (TrA–IO/EO) compared to the Verbal group (p = 0.004). Ultrasound analysis revealed significantly greater increases in TrA thickness and contractile activity in the Visual group (p < 0.001). A significant positive correlation was observed between changes in TrA–IO activation and TrA thickness (ρ = 0.51, p < 0.001). Conclusions: Portable sEMG-based visual biofeedback demonstrated physiological relevance by reflecting ultrasound-derived changes in deep abdominal muscle function. These findings support the use of sEMG as a practical surrogate tool for monitoring deep core muscle activation and highlight the potential of portable biofeedback systems in scalable and accessible rehabilitation.
- 8 June 2026
- Published by MDPI AG in Healthcare
- Vol. 14 (12) , 1606
Open AccessMultimodal Validation of an sEMG-Based Visual Biofeedback System for Deep Abdominal Muscle Activation in Healthy Adults: A Randomized Controlled Proof-of-Concept Trial
Background: Portable biofeedback technologies are increasingly used in rehabilitation; however, the validity of surface electromyography (sEMG) as a surrogate indicator of deep abdominal muscle function remains unclear. This study aimed to validate a portable sEMG-based visual biofeedback system by examining its relationship with ultrasound-derived measures of deep abdominal muscle activation. Methods: Twenty-nine healthy adults were randomly assigned to a Visual Biofeedback group (n = 14) or a Verbal Feedback group (n = 15). Both groups performed a standardized 2-week core stabilization program. Muscle activation of the deep abdominal muscle complex (transversus abdominis–internal oblique; TrA–IO) and external oblique (EO) was measured using sEMG (%MVIC), while ultrasound imaging was used to assess transversus abdominis thickness and contractile activity (ADIM–Rest index). Between-group differences and correlations between EMG and ultrasound variables were analyzed. Results: The Visual Biofeedback group demonstrated significantly greater improvements in TrA–IO activation and in the preferential activation ratio (TrA–IO/EO) compared to the Verbal group (p = 0.004). Ultrasound analysis revealed significantly greater increases in TrA thickness and contractile activity in the Visual group (p < 0.001). A significant positive correlation was observed between changes in TrA–IO activation and TrA thickness (ρ = 0.51, p < 0.001). Conclusions: Portable sEMG-based visual biofeedback demonstrated physiological relevance by reflecting ultrasound-derived changes in deep abdominal muscle function. These findings support the use of sEMG as a practical surrogate tool for monitoring deep core muscle activation and highlight the potential of portable biofeedback systems in scalable and accessible rehabilitation.
- 28 February 2026
- Published by Institute of Control, Robotics and Systems in Journal of Institute of Control, Robotics and Systems
- Vol. 32 (2) , 141-149
Real-time Exercise Posture and Muscle Strength Feedback System: Integrating Pose Tracking Model, ArUco Marker, and EMG Sensor
Improper posture during exercise can lead to injuries, and the use of visual feedback has been demonstrated to positively affect exercise efficacy and injury prevention. Individuals who exercise independently often follow instructional videos for guidance. To improve exercise effectiveness and minimize the risk of injury, we propose a system that provides real-time visual feedback. This system utilizes MediaPipe for movement estimation and incorporates ArUco markers to compensate for occlusions caused by exercise equipment. Furthermore, electromyography (EMG) is employed to assess whether the appropriate muscles are being activated. In instances where correct posture and muscle activation are not achieved, the system prevents further progress in the exercise repetitions and notifies the user of a failure to meet the required conditions. The experimental results demonstrated that the proposed compensation algorithm reduced the mean absolute error of posture estimation from 9.010° to 2.270°, a reduction of approximately 74.8%. Consequently, the exercise success rate significantly improved from 62.7% to 87.3%, confirming that the system is effective in enhancing exercise performance while preventing injuries.
- 28 February 2026
- Published by Institute of Control, Robotics and Systems in Journal of Institute of Control, Robotics and Systems
- Vol. 32 (2) , 141-149
Real-time Exercise Posture and Muscle Strength Feedback System: Integrating Pose Tracking Model, ArUco Marker, and EMG Sensor
Improper posture during exercise can lead to injuries, and the use of visual feedback has been demonstrated to positively affect exercise efficacy and injury prevention. Individuals who exercise independently often follow instructional videos for guidance. To improve exercise effectiveness and minimize the risk of injury, we propose a system that provides real-time visual feedback. This system utilizes MediaPipe for movement estimation and incorporates ArUco markers to compensate for occlusions caused by exercise equipment. Furthermore, electromyography (EMG) is employed to assess whether the appropriate muscles are being activated. In instances where correct posture and muscle activation are not achieved, the system prevents further progress in the exercise repetitions and notifies the user of a failure to meet the required conditions. The experimental results demonstrated that the proposed compensation algorithm reduced the mean absolute error of posture estimation from 9.010° to 2.270°, a reduction of approximately 74.8%. Consequently, the exercise success rate significantly improved from 62.7% to 87.3%, confirming that the system is effective in enhancing exercise performance while preventing injuries.
- Open Access
- 19 January 2026
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 27 (5) , 2111-2120
Comparative Effects of Low-Frequency High-Intensity and High-Frequency Low-Intensity TENS on Neuromuscular Activation in Myofascial Pain Syndrome: A Randomized Controlled Trial
Myofascial pain syndrome (MPS) of the upper trapezius is characterized by trigger-point–related pain, restricted cervical motion, and altered muscle activation patterns. Electrical stimulation is a widely used noninvasive intervention, yet the influence of different frequency–intensity combinations remains insufficiently defined. This randomized controlled trial compared the short-term effects of low-frequency high-intensity (LFHI) and high-frequency low-intensity (HFLI) transcutaneous electrical nerve stimulation (TENS) on pain, cervical range of motion (ROM), muscle tone, and muscle activation in adults with upper trapezius MPS. Thirty participants were randomly assigned to either the LFHI or HFLI protocol and received 20-minute treatments twice daily for five days. Pain intensity (numeric rating scale), pressure pain threshold, cervical ROM, upper trapezius muscle tone, and surface electromyography (sEMG) of the upper trapezius, middle deltoid, and levator scapulae were assessed before and after intervention. Both LFHI and HFLI stimulation significantly reduced pain intensity and increased pressure pain threshold ( p < .01). Cervical ROM in all directions improved significantly in both groups ( p < .01), accompanied by reductions in upper trapezius muscle tone ( p < .01). sEMG analysis revealed decreased upper trapezius and levator scapulae activity and increased deltoid activation in both groups ( p < .01). Although no significant intergroup differences were observed for most parameters, the deltoid-to–upper trapezius activation ratio increased significantly only in the HFLI group ( p < .05), indicating a more favorable motor recruitment pattern. These findings demonstrate that both LFHI and HFLI electrical stimulation protocols effectively relieve pain, reduce muscle hypertonicity, and enhance cervical mobility in individuals with MPS. While clinical outcomes were comparable, HFLI stimulation may provide additional benefits in normalizing shoulder muscle activation. Electrical stimulation represents a practical and accessible modality for restoring short-term neuromuscular function in MPS.
- 19 January 2026
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 27 (5) , 2111-2120
Open AccessComparative Effects of Low-Frequency High-Intensity and High-Frequency Low-Intensity TENS on Neuromuscular Activation in Myofascial Pain Syndrome: A Randomized Controlled Trial
Myofascial pain syndrome (MPS) of the upper trapezius is characterized by trigger-point–related pain, restricted cervical motion, and altered muscle activation patterns. Electrical stimulation is a widely used noninvasive intervention, yet the influence of different frequency–intensity combinations remains insufficiently defined. This randomized controlled trial compared the short-term effects of low-frequency high-intensity (LFHI) and high-frequency low-intensity (HFLI) transcutaneous electrical nerve stimulation (TENS) on pain, cervical range of motion (ROM), muscle tone, and muscle activation in adults with upper trapezius MPS. Thirty participants were randomly assigned to either the LFHI or HFLI protocol and received 20-minute treatments twice daily for five days. Pain intensity (numeric rating scale), pressure pain threshold, cervical ROM, upper trapezius muscle tone, and surface electromyography (sEMG) of the upper trapezius, middle deltoid, and levator scapulae were assessed before and after intervention. Both LFHI and HFLI stimulation significantly reduced pain intensity and increased pressure pain threshold ( p < .01). Cervical ROM in all directions improved significantly in both groups ( p < .01), accompanied by reductions in upper trapezius muscle tone ( p < .01). sEMG analysis revealed decreased upper trapezius and levator scapulae activity and increased deltoid activation in both groups ( p < .01). Although no significant intergroup differences were observed for most parameters, the deltoid-to–upper trapezius activation ratio increased significantly only in the HFLI group ( p < .05), indicating a more favorable motor recruitment pattern. These findings demonstrate that both LFHI and HFLI electrical stimulation protocols effectively relieve pain, reduce muscle hypertonicity, and enhance cervical mobility in individuals with MPS. While clinical outcomes were comparable, HFLI stimulation may provide additional benefits in normalizing shoulder muscle activation. Electrical stimulation represents a practical and accessible modality for restoring short-term neuromuscular function in MPS.
- Open Access
- 25 December 2025
- Published by American Chemical Society (ACS) in ACS Polymers Au
- Vol. 6 (1) , 445-453
Tunable Wetting and Chemical Coating-Free Slip on Wrinkled PDMS for Droplet Microfluidics
Microfluidic systems offer significant advantages in handling small sample volumes while enabling high-throughput experimentation and precise flow control. Surface wettability critically governs droplet-generation efficiency and flow characteristics in microfluidic channels. Topographic modulation of polymer surfaces provides a simple, chemical-free route to tune wettability. We present a surface-engineering strategy that patterns nanoscale wrinkles on polydimethylsiloxane (PDMS), optimized at 40 ϵ prestrain, 100 W oxygen-plasma power, and 12 min exposure. The resulting wrinkled PDMS exhibited stable hydrophobicity sufficient for reliable water-in-oil droplet generation without any coating. Wettability was quantified by contact-angle measurements, and wrinkle morphology was verified by 3D laser profilometry and atomic force microscopy. Orientation-dependent hydrophobicity and droplet-generation behavior were also assessed. Finite-element simulations showed enhanced interfacial slip at wrinkled walls relative to flat walls under matched driving and captured orientation effects on near-wall kinematics. The approach circumvents hydrophobic-recovery and coating-compatibility issues commonly encountered with silane-treated PDMS. Therefore, the results establish mechanically engineered surface wrinkles as an effective, chemical-free means to tune hydrophobicity in microfluidic devices, with direct relevance to droplet-based assays and lab-on-a-chip platforms.
- 25 December 2025
- Published by American Chemical Society (ACS) in ACS Polymers Au
- Vol. 6 (1) , 445-453
Open AccessTunable Wetting and Chemical Coating-Free Slip on Wrinkled PDMS for Droplet Microfluidics
Microfluidic systems offer significant advantages in handling small sample volumes while enabling high-throughput experimentation and precise flow control. Surface wettability critically governs droplet-generation efficiency and flow characteristics in microfluidic channels. Topographic modulation of polymer surfaces provides a simple, chemical-free route to tune wettability. We present a surface-engineering strategy that patterns nanoscale wrinkles on polydimethylsiloxane (PDMS), optimized at 40 ϵ prestrain, 100 W oxygen-plasma power, and 12 min exposure. The resulting wrinkled PDMS exhibited stable hydrophobicity sufficient for reliable water-in-oil droplet generation without any coating. Wettability was quantified by contact-angle measurements, and wrinkle morphology was verified by 3D laser profilometry and atomic force microscopy. Orientation-dependent hydrophobicity and droplet-generation behavior were also assessed. Finite-element simulations showed enhanced interfacial slip at wrinkled walls relative to flat walls under matched driving and captured orientation effects on near-wall kinematics. The approach circumvents hydrophobic-recovery and coating-compatibility issues commonly encountered with silane-treated PDMS. Therefore, the results establish mechanically engineered surface wrinkles as an effective, chemical-free means to tune hydrophobicity in microfluidic devices, with direct relevance to droplet-based assays and lab-on-a-chip platforms.
- Open Access
- 3 October 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (10) , 1078
The Optimal Fibular Strut Bone Graft Fixation Angle for Unstable Proximal Humerus Fractures: A Finite Element Analysis
Adding a fibular strut bone graft to locking plate fixation has been introduced to improve stability and prevent varus collapse. The purpose of this study was to perform finite element analysis (FEA) of the biomechanical characteristics of different insertion angles of the fibular strut graft in proximal humerus fractures. Proximal humerus fractures with metaphyseal comminution and instability were simulated by creating wedge-shaped osteotomies medially and laterally for varus and valgus models, respectively. Three-dimensional finite element models were reconstructed from computed tomography images. A locking compression plate with a length of 90 mm (three holes) was applied to the proximal humerus fracture model. Fibular allografts were inserted at 0° and 30° to the humeral shaft. Axial and traction forces of 70°, 90°, and 110° relative to the vertical axis were applied to each model to simulate stress on the plate and graft. At axial loads, stresses in both the plate and the graft were lower when the graft was inserted at 0° than at 30°. Under traction loads, plate stress was lower with 30° insertion. Graft stress was also lower with 30° in most experimental conditions in both the valgus and varus models. These findings suggest that oblique insertion may provide biomechanical advantages under traction forces in unstable proximal humerus fractures.
- 3 October 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (10) , 1078
Open AccessThe Optimal Fibular Strut Bone Graft Fixation Angle for Unstable Proximal Humerus Fractures: A Finite Element Analysis
Adding a fibular strut bone graft to locking plate fixation has been introduced to improve stability and prevent varus collapse. The purpose of this study was to perform finite element analysis (FEA) of the biomechanical characteristics of different insertion angles of the fibular strut graft in proximal humerus fractures. Proximal humerus fractures with metaphyseal comminution and instability were simulated by creating wedge-shaped osteotomies medially and laterally for varus and valgus models, respectively. Three-dimensional finite element models were reconstructed from computed tomography images. A locking compression plate with a length of 90 mm (three holes) was applied to the proximal humerus fracture model. Fibular allografts were inserted at 0° and 30° to the humeral shaft. Axial and traction forces of 70°, 90°, and 110° relative to the vertical axis were applied to each model to simulate stress on the plate and graft. At axial loads, stresses in both the plate and the graft were lower when the graft was inserted at 0° than at 30°. Under traction loads, plate stress was lower with 30° insertion. Graft stress was also lower with 30° in most experimental conditions in both the valgus and varus models. These findings suggest that oblique insertion may provide biomechanical advantages under traction forces in unstable proximal humerus fractures.
- 20 May 2024
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 25 (7) , 1465-1473
Optimized Clavicle Hook Plate Geometry for Average Korean Clavicle–Acromion Dimensions: A Finite Element Analysis Study
- 20 May 2024
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 25 (7) , 1465-1473
Optimized Clavicle Hook Plate Geometry for Average Korean Clavicle–Acromion Dimensions: A Finite Element Analysis Study
- 10 June 2022
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 23 (7) , 789-796
Evaluating the Stability of Locking Screw on Locking Compression Plate According to Various Screw Insertion Angles
- 10 June 2022
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 23 (7) , 789-796
Evaluating the Stability of Locking Screw on Locking Compression Plate According to Various Screw Insertion Angles
- Open Access
- 18 August 2016
- Published by MDPI AG in Nanomaterials
- Vol. 6 (8) , 149
Receptor-Meditated Endocytosis by Hyaluronic Acid@Superparamagnetic Nanovetor for Targeting of CD44-Overexpressing Tumor Cells
The present report proposes a more rational hyaluronic acid (HA) conjugation protocol that can be used to modify the surface of the superparamagnetic iron oxide nanoparticles (SPIONs) by covalently binding the targeting molecules (HA) with glutamic acid as a molecular linker on peripheral surface of SPIONs. The synthesis of HA-Glutamic Acid (GA)@SPIONs was included oxidization of nanoparticle’s surface with H2O2 followed by activation of hydroxyl group and reacting glutamic acid as an intermediate molecule demonstrating transfection of lung cancer cells. Fourier transform infrared (FTIR) and zeta-potential studies confirmed the chemical bonding between amino acid linker and polysaccharides. 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) cytotoxicity assay showed that HA-SPIONs-treated cells remained 82.9% ± 2.7% alive at high particle dosage (200 µg/mL iron concentration), whereas GA-SPIONs and bare SPIONs (B-SPIONs) treated cells had only 59.3% ± 13.4% and 26.5% ± 3.1% survival rate at the same conditions, respectively. Confocal microscopy analysis showed increased cellular internalization of HA-SPIONs compared to non-interacting agarose coated SPIONs (AgA-SPIONs).
- 18 August 2016
- Published by MDPI AG in Nanomaterials
- Vol. 6 (8) , 149
Open AccessReceptor-Meditated Endocytosis by Hyaluronic Acid@Superparamagnetic Nanovetor for Targeting of CD44-Overexpressing Tumor Cells
The present report proposes a more rational hyaluronic acid (HA) conjugation protocol that can be used to modify the surface of the superparamagnetic iron oxide nanoparticles (SPIONs) by covalently binding the targeting molecules (HA) with glutamic acid as a molecular linker on peripheral surface of SPIONs. The synthesis of HA-Glutamic Acid (GA)@SPIONs was included oxidization of nanoparticle’s surface with H2O2 followed by activation of hydroxyl group and reacting glutamic acid as an intermediate molecule demonstrating transfection of lung cancer cells. Fourier transform infrared (FTIR) and zeta-potential studies confirmed the chemical bonding between amino acid linker and polysaccharides. 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) cytotoxicity assay showed that HA-SPIONs-treated cells remained 82.9% ± 2.7% alive at high particle dosage (200 µg/mL iron concentration), whereas GA-SPIONs and bare SPIONs (B-SPIONs) treated cells had only 59.3% ± 13.4% and 26.5% ± 3.1% survival rate at the same conditions, respectively. Confocal microscopy analysis showed increased cellular internalization of HA-SPIONs compared to non-interacting agarose coated SPIONs (AgA-SPIONs).
- 10 July 2016
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 17 (7) , 949-956
The trunk muscles activity on whole body vibration during bridging position in young healthy adults
- 10 July 2016
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 17 (7) , 949-956
The trunk muscles activity on whole body vibration during bridging position in young healthy adults