Peng Du
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Peng Du has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Feng Fan
Harbin Institute of Technology
2 shared publicationsZhenggang Cao
Key Lab of Structures Dynamic Behavior and Control of the Ministry of Education, Harbin Institute of Technology, Harbin, China
2 shared publicationsCao Zhenggang
Key Lab of Structures Dynamic Behavior and Control of the Ministry of Education, Harbin Institute of Technology, Harbin, China
1 shared publicationFan Feng
Key Lab of Structures Dynamic Behavior and Control of the Ministry of Education, Harbin Institute of Technology, Harbin, China
1 shared publicationFang Ming
China Institute of Building Standard Design & Research, Beijing, China
1 shared publicationJiangdong Li
Chengdu Vanke Real Estate Co. Ltd., Chengdu, China
1 shared publication
Latest Publications
- 9 June 2017
- Published by Zhejiang University Press in Journal of Zhejiang University-SCIENCE A
- Vol. 18 (6) , 454-466
Pseudo-dynamic testing of a fabricated composite frame with steel plate shear walls
A pseudo-dynamic testing program was generated on a fabricated composite frame with steel plate shear walls (SPSWs) to study its seismic performance. The specimen was a three-storey single-bay frame, which was composed of H-section steel columns and composite beams, and was assembled by bolted height-adjustable steel beam-to-column connections (BHA connections). Beam-only-connected SPSWs were selected as lateral load resisting members. The specimen was subjected to four ground motions of progressively increasing intensity. The results showed that: (1) beam-only-connected SPSWs provided sufficient lateral load resistance, lateral stiffness, and energy dissipation capacity to the fabricated frame via the tension field action developed in their infill panels; (2) the fabricated frame, assembled by BHA connections, exhibited substantial redundancy and good ductility; (3) an undesirable failure mode of the fabricated frame, in huge earthquakes, included severe cracking in composite beams and block shear failure in SPSWs’ connections; (4) the inter-storey shear force distribution determined by ASCE/SEI 7-10 was verified with experimental data.
- 9 June 2017
- Published by Zhejiang University Press in Journal of Zhejiang University-SCIENCE A
- Vol. 18 (6) , 454-466
Pseudo-dynamic testing of a fabricated composite frame with steel plate shear walls
A pseudo-dynamic testing program was generated on a fabricated composite frame with steel plate shear walls (SPSWs) to study its seismic performance. The specimen was a three-storey single-bay frame, which was composed of H-section steel columns and composite beams, and was assembled by bolted height-adjustable steel beam-to-column connections (BHA connections). Beam-only-connected SPSWs were selected as lateral load resisting members. The specimen was subjected to four ground motions of progressively increasing intensity. The results showed that: (1) beam-only-connected SPSWs provided sufficient lateral load resistance, lateral stiffness, and energy dissipation capacity to the fabricated frame via the tension field action developed in their infill panels; (2) the fabricated frame, assembled by BHA connections, exhibited substantial redundancy and good ductility; (3) an undesirable failure mode of the fabricated frame, in huge earthquakes, included severe cracking in composite beams and block shear failure in SPSWs’ connections; (4) the inter-storey shear force distribution determined by ASCE/SEI 7-10 was verified with experimental data.
- 31 March 2017
- Published by Springer Nature in International Journal of Steel Structures
- Vol. 17 (1) , 77-89
Cyclic testing and parametric study of bolted beam-height adjustable steel beam-to-column connections
- 31 March 2017
- Published by Springer Nature in International Journal of Steel Structures
- Vol. 17 (1) , 77-89
Cyclic testing and parametric study of bolted beam-height adjustable steel beam-to-column connections
- 26 July 2016
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 20 (4) , 629-640
Cyclic testing and parametric analyses of the fabricated steel frames infilled with autoclaved aerated concrete panels
The influence of autoclaved aerated concrete panels on the mechanical properties of fabricated steel frames was experimentally investigated. Two fabricated steel frame specimens, which were with and without autoclaved aerated concrete panels, respectively, were tested under reversed cyclic loads. They were 1/2-scale, two-storey, and single-bay steel frames that were assembled by bolted beam-height adjustable steel beam-to-column connections. The effect of autoclaved aerated concrete panel dimensions on the mechanical behavior of infilled frames was also parametrically analyzed with the proposed numerical models which were verified on the basis of experimental data. The results indicate that the fabricated steel frames, assembled by beam-height adjustable connections, could behave in a ductile manner with sufficient stiffness and strength under cyclic loads; compared with bare steel frames, autoclaved aerated concrete panels could postpone the failure of structures and increase their initial stiffness, peak load, and energy dissipation capacity; moreover, the geometric details of autoclaved aerated concrete panels could significantly change the mechanical properties of infilled steel frames.
- 26 July 2016
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 20 (4) , 629-640
Cyclic testing and parametric analyses of the fabricated steel frames infilled with autoclaved aerated concrete panels
The influence of autoclaved aerated concrete panels on the mechanical properties of fabricated steel frames was experimentally investigated. Two fabricated steel frame specimens, which were with and without autoclaved aerated concrete panels, respectively, were tested under reversed cyclic loads. They were 1/2-scale, two-storey, and single-bay steel frames that were assembled by bolted beam-height adjustable steel beam-to-column connections. The effect of autoclaved aerated concrete panel dimensions on the mechanical behavior of infilled frames was also parametrically analyzed with the proposed numerical models which were verified on the basis of experimental data. The results indicate that the fabricated steel frames, assembled by beam-height adjustable connections, could behave in a ductile manner with sufficient stiffness and strength under cyclic loads; compared with bare steel frames, autoclaved aerated concrete panels could postpone the failure of structures and increase their initial stiffness, peak load, and energy dissipation capacity; moreover, the geometric details of autoclaved aerated concrete panels could significantly change the mechanical properties of infilled steel frames.
- 30 June 2016
- Published by Springer Nature in International Journal of Steel Structures
- Vol. 16 (2) , 279-288
The stability and stressed skin effect analyses of an 80 m diameter single-layer latticed dome with bolt-ball joints
- 30 June 2016
- Published by Springer Nature in International Journal of Steel Structures
- Vol. 16 (2) , 279-288
The stability and stressed skin effect analyses of an 80 m diameter single-layer latticed dome with bolt-ball joints