Elisa Ventura
Research Subjects
Elisa Ventura has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Sara Bonasia
Rothschild Foundation Hospital
3 shared publicationsThomas Robert
University of the Southern Switzerland
3 shared publicationsS. Smajda
Rothschild Foundation Hospital
2 shared publications- Alberto Di Napoli
Neuroradiology Unit, NESMOS Department, Sant’Andrea Hospital, La Sapienza University, Via di Grottarossa 1035, 00189 Rome, Italy
1 shared publication Alessandro Cianfoni
From the Neurocenter of Southern Switzerland, Regional Hospital of Lugano, Switzerland
1 shared publication- Alessandro Cianfoni
Ospedale Regionale di Lugano
1 shared publication
Latest Publications
- 1 October 2023
- Published by Springer Nature
- p. 333-340
Intratympanic Flow of the Internal Carotid Artery
- 1 October 2023
- Published by Springer Nature
- p. 333-340
Intratympanic Flow of the Internal Carotid Artery
- 1 October 2023
- Published by Springer Nature
- p. 41-57
Segmental Agenesis of the Internal Carotid Artery
- 1 October 2023
- Published by Springer Nature
- p. 129-143
Cortical and Perforating Branches of the Middle Cerebral Artery
- 1 October 2023
- Published by Springer Nature
- p. 129-143
Cortical and Perforating Branches of the Middle Cerebral Artery
- 5 July 2022
- Published by Springer Nature in Neuroradiology
- Vol. 64 (10) , 2039-2047
Gantry-needle-target alignment technique for CT-guided needle approaches to the skull base and cranio-cervical junction
Purpose CT-guided percutaneous procedures involving the skull base and atlanto-axial cervical spine pose particular challenges due to high density of vital vascular and nervous structures and because the ideal needle trajectory often has a cranio-caudal obliquity different from the axial scan plane. We describe how the variable CT gantry tilt, combined with gantry-needle-target alignment technique, is used to obtain precise and safe needle placement in conventional and non-conventional approaches to the skull base and the atlanto-axial spine. Methods We retrospectively analyzed consecutive CT-guided needle accesses to the skull base and atlanto-axial spine performed for tissue sampling through fine-needle aspirates and core biopsies, cementoplasty of neoplastic lytic lesions of atlanto-axial spine, pain management injections, and dural puncture for cerebro-spinal fluid sampling. All the accesses were performed with the gantry-needle-target alignment technique. Procedural complications were recorded. Results Thirty-nine CT-guided procedures were analyzed. Paramaxillary approach was used in 15 cases, postero-lateral in 11, subzygomatic in 3. Nine non-conventional approach were performed: submastoid in 3 cases, suprazygomatic in 2, trans-nasal in 2, trans-mastoid in 1, and trans-auricular in 1. Two peri-procedural complications occurred: one asymptomatic and one resolved within 24 h. All the procedures were successfully completed with successful needle access to the target. Conclusion The gantry tilt and gantry-needle-target alignment technique allows to obtain double-oblique needle accesses for CT-guided procedures involving the skull base and atlanto-axial cervical spine, minimizing uncertainty of needle trajectory and obtaining safe needle placement in conventional and non-conventional approaches.
- 5 July 2022
- Published by Springer Nature in Neuroradiology
- Vol. 64 (10) , 2039-2047
Gantry-needle-target alignment technique for CT-guided needle approaches to the skull base and cranio-cervical junction
Purpose CT-guided percutaneous procedures involving the skull base and atlanto-axial cervical spine pose particular challenges due to high density of vital vascular and nervous structures and because the ideal needle trajectory often has a cranio-caudal obliquity different from the axial scan plane. We describe how the variable CT gantry tilt, combined with gantry-needle-target alignment technique, is used to obtain precise and safe needle placement in conventional and non-conventional approaches to the skull base and the atlanto-axial spine. Methods We retrospectively analyzed consecutive CT-guided needle accesses to the skull base and atlanto-axial spine performed for tissue sampling through fine-needle aspirates and core biopsies, cementoplasty of neoplastic lytic lesions of atlanto-axial spine, pain management injections, and dural puncture for cerebro-spinal fluid sampling. All the accesses were performed with the gantry-needle-target alignment technique. Procedural complications were recorded. Results Thirty-nine CT-guided procedures were analyzed. Paramaxillary approach was used in 15 cases, postero-lateral in 11, subzygomatic in 3. Nine non-conventional approach were performed: submastoid in 3 cases, suprazygomatic in 2, trans-nasal in 2, trans-mastoid in 1, and trans-auricular in 1. Two peri-procedural complications occurred: one asymptomatic and one resolved within 24 h. All the procedures were successfully completed with successful needle access to the target. Conclusion The gantry tilt and gantry-needle-target alignment technique allows to obtain double-oblique needle accesses for CT-guided procedures involving the skull base and atlanto-axial cervical spine, minimizing uncertainty of needle trajectory and obtaining safe needle placement in conventional and non-conventional approaches.
- Open Access
- 12 July 2016
- Published by Wolters Kluwer Health in Neurology
- Vol. 87 (2) , 234-235
MR neurography of a vagal neuropathy
- 12 July 2016
- Published by Wolters Kluwer Health in Neurology
- Vol. 87 (2) , 234-235
Open AccessMR neurography of a vagal neuropathy