JDJohn J. Davenport

John J. Davenport

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


John J. Davenport has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    NAIR: novel astronomical instrumentation through photonic reformatting

    by Robert J. Harris, Tarun Kumar Sharma, John J. Davenport, Philipp Hottinger, Theodoros Anagnos, Abani S. Nayak, Andreas Quirrenbach, Lucas Labadie, Kalaga V. Madhav, Martin M. Roth

    SPIE Digital Library Proceedings


  • Open Access

    NAIR: novel astronomical instrumentation through photonic reformatting

    by Ettore Pedretti, Robert J. Harris, Stefano Minardi, Jan Tepper, John J. Davenport, Philipp Hottinger, Theodoros Anagnos, Abani Shankar Nayak, Andreas Quirrenbach, Lucas Labadie, et al.

    The project "Novel Astronomical Instrumentation based on photonic light Reformating" is a DFG-funded collaboration to exploit the recognized potential of photonics solutions for a radically new approach to astronomical instrumentation for optical/infrared high precision spectroscopy and high angular resolution imaging. We present a project overview and initial development results from our Adaptive Optics-photonic test bed, Ultrafast Laser Inscribed waveguides for interferometric beam combination and 3D printing structures for astronomical instrumentation. The project is expected to lead to important technological breakthroughs facilitating uniquely functionality and technical solutions for the next generation of instrumentation.


  • Dual pO2/pCO2fibre optic sensing film

    by John J. Davenport, Michelle Hickey, Justin P. Phillips, Panayiotis A. Kyriacou

    A fibre optic multi-sensor has been developed for biomedical sensing applications using a tip coating solution sensitive to both oxygen and carbon dioxide. An oxygen sensitive phosphorescence quenching complex based on platinum octaethylporphyrin (PtOEP) was combined with a carbon dioxide sensitive phosphorescence compound based on 8-hydroxypyrene-1,3,6-trisulfonic acid trisodium salt (HPTS). When excited by blue light (470 nm), the resultant coating had two fluorescent peaks at 515 nm (green) and 645 nm (red) which responded to partial pressure of CO2 and O2 respectively. The sensor was tested in vitro and shown to be able to measure CO2 and O2 simultaneously and in real time, with calibration constants of 0.0384 kPa−1 and 0.309 kPa−1 respectively. The O2 sensitive peak received some overlap from the 515 nm peak (0.38% of peak intensity) as well as some cross-sensitivity (maximum, 5.1 kPa pCO2 gave a measurement equivalent to 0.43 kPa of O2, a ratio of 0.08 : 1). However, these effects can be subtracted from measurements and no significant cross-sensitivity or overlap was seen in CO2 measurements from O2. This novel compound presents great potential for use in medical sensors and we expect it to be important to a wide range of future applications.


  • Fiber-optic fluorescence-quenching oxygen partial pressure sensor using platinum octaethylporphyrin

    by John J. Davenport, Michelle Hickey, Justin P. Phillips, Panayiotis A. Kyriacou

    The development and bench testing of a fiber-optic oxygen sensor is described. The sensor is designed for measurement of tissue oxygen levels in the mucosa of the digestive tract. The materials and construction are optimized for insertion through the mouth for measurement in the lower esophagus. An oxygen-sensitive fluorescence-quenching film was applied as a solution of platinum octaethylporphyrin (PtOEP) poly(ethyl methacrylate) (PEMA) and dichloromethane and dip coated onto the distal tip of the fiber. The sensor was tested by comparing relative fluorescence when immersed in liquid water at 37°C, at a range of partial pressures (0–101 kPa). Maximum relative fluorescence at most oxygen concentrations was seen when the PtOEP concentration was 0.1 g.L−1, four layers of coating solution were applied, and a fiber core radius of 600 μm was selected, giving a Stern–Volmer constant of 0.129 kPa−1. The performance of the sensor is suitable for many in vivo applications, particularly mucosal measurements. It has sufficient sensitivity, is sterilizable, and is sufficiently flexible and robust for insertion via the mouth without damage to the probe or risk of harm to the patient.