HFH. Fujisaki

H. Fujisaki

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


H. Fujisaki has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • H. Nagata

    Nikon Corporation, Tsukuba Research Laboratory, 5‐9‐1 Tokodai, Tsukuba, Ibaraki 300‐26, Japan

    2 shared publications
  • H. Kato

    Waseda University, Department of Physics, School of Science and Engineering, 3‐4‐1 Okubo, Shinjuku, Tokyo 169, Japan

    1 shared publication
  • H. Kondo

    Nikon Corporation, Tsukuba Research Laboratory, 5‐9‐1 Tokodai, Tsukuba, Ibaraki 300‐26, Japan

    1 shared publication
  • H. Ohzeki

    Nikon Corporation, New Business Development Department, 1‐6‐3 Nishi‐Ohi, Shinagawa, Tokyo 140, Japan

    1 shared publication
  • K. Sugisaki

    Nikon Corporation, New Business Development Department, 1‐6‐3 Nishi‐Ohi, Shinagawa, Tokyo 140, Japan

    1 shared publication
  • N. Kihara

    Yoshida Nano-Mechanism Project, JRDC, 1-6-3 Nishi-ohi, Shinagawa-ku, Tokyo 140, Japan

    1 shared publication

Latest Publications

  • Soft‐X‐ray damage to biological samples

    by H. Fujisaki, S. Takahashi, H. Ohzeki, K. Sugisaki, H. Kondo, H. Nagata, H. Kato, S. Ishiwata

    X‐ray damage to biological samples was investigated in the wavelength region of 2.7–5 nm, which overlaps the so‐called ‘water window’, the wavelength range of 2.4–4.3 nm usually used in X‐ray microscopy. Yeast cells and myofibrils were chosen as representatives of whole cell samples and motile protein systems, respectively. The samples were exposed to X‐rays using an apparatus composed mainly of a laser‐plasma X‐ray source, a Wolter mirror condenser, and a sample cell. The yeast cells lost their dye exclusion ability when the X‐ray flux was higher than 1 × 106 photons μm−2, while the myofibrils lost contractility when the X‐ray flux was higher than 4 × 105 photons μm−2. These X‐ray fluxes are lower than the flux required for the X‐ray microscope observation of biological samples at a resolution higher than that of light microscopes.


  • Optical constants for coated thin films in the soft x-ray region

    by N. Kihara, H. Nagata, N. Nakagiri, H. Fujisaki, T. Miyahara

    We present optical constants for Ti, V, and Ni in the 2–4.5 nm wavelength region. The reflected synchrotron radiation intensity was measured at more than 30 incident angles for each wavelength. A protective layer of carbon was sputtered onto each sample to prevent surface oxidization. A three‐phase model was used to analyze the data. Instead of replacing some of the parameters by values determined by other experimental methods, eight parameters were simultaneously used in the least squares fitting. A 5‐nm layer of carbon was found to be thin enough not to cause significant errors in the derived optical constants of the test materials.