Wilson Schreiber
Research Subjects
Wilson Schreiber has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Maciej M. Kmiec
Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH, USA
2 shared publicationsSergey V. Petryakov
Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH, USA
2 shared publicationsAnn Barry Flood
Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA
1 shared publicationBenjamin B. Williams
Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA
1 shared publication- Benjamin B. Williams
Department of Radiology, Geisel School of Medicine at Dartmouth, Hanover, USA
1 shared publication Harold M. Swartz
Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA
1 shared publication
Latest Publications
- Open Access
- 23 December 2016
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 172 (1-3) , 127-132
Surface Dielectric Resonators for X-band EPR Spectroscopy
A new resonator for X-band electron paramagnetic resonance (EPR) spectroscopy, which utilizes the unique resonance properties of dielectric substrates, has been developed using a single crystal of titanium dioxide. As a result of the dielectric properties of the crystal(s) chosen, this novel resonator provides the ability to make in vivo EPR spectroscopy surface measurements in the presence of lossy tissues at X-band frequencies (up to 10 GHz). A double-loop coupling device is used to transmit and receive microwave power to/from the resonator. This coupler has been developed and optimized for coupling to the resonator in the presence of lossy tissues to further enable in vivo measurements, such as in vivo EPR spectroscopy of human fingernails or teeth to measure the dose of ionizing radiation that a given individual has been exposed to. An advantage of this resonator for surface measurements is that the magnetic fields generated by the resonator are inherently shallow, which is desirable for in vivo nail dosimetry.
- 23 December 2016
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 172 (1-3) , 127-132
Open AccessSurface Dielectric Resonators for X-band EPR Spectroscopy
A new resonator for X-band electron paramagnetic resonance (EPR) spectroscopy, which utilizes the unique resonance properties of dielectric substrates, has been developed using a single crystal of titanium dioxide. As a result of the dielectric properties of the crystal(s) chosen, this novel resonator provides the ability to make in vivo EPR spectroscopy surface measurements in the presence of lossy tissues at X-band frequencies (up to 10 GHz). A double-loop coupling device is used to transmit and receive microwave power to/from the resonator. This coupler has been developed and optimized for coupling to the resonator in the presence of lossy tissues to further enable in vivo measurements, such as in vivo EPR spectroscopy of human fingernails or teeth to measure the dose of ionizing radiation that a given individual has been exposed to. An advantage of this resonator for surface measurements is that the magnetic fields generated by the resonator are inherently shallow, which is desirable for in vivo nail dosimetry.
- 15 July 2016
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 172 (1-3) , 87-95
FLEXIBLE, WIRELESS, INDUCTIVELY COUPLED SURFACE COIL RESONATOR FOR EPR TOOTH DOSIMETRY
Managing radiation injuries following a catastrophic event where large numbers of people may have been exposed to life-threatening doses of ionizing radiation relies on the availability of biodosimetry to assess whether individuals need to be triaged for care. Electron Paramagnetic Resonance (EPR) tooth dosimetry is a viable method to accurately estimate the amount of ionizing radiation to which an individual has been exposed. In the intended measurement conditions and scenario, it is essential that the measurement process be fast, straightforward and provides meaningful and accurate dose estimations for individuals in the expected measurement conditions. The sensing component of a conventional L-band EPR spectrometer used for tooth dosimetry typically consists of a surface coil resonator that is rigidly, physically attached to the coupler. This design can result in cumbersome operation, limitations in teeth geometries that may be measured and hinder the overall utility of the dosimeter. A novel surface coil resonator has been developed for the currently existing L-band (1.15 GHz) EPR tooth dosimeter for the intended use as a point of care device by minimally trained operators. This resonator development provides further utility to the dosimeter, and increases the usability of the dosimeter by non-expert operators in the intended use scenario.
- 15 July 2016
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 172 (1-3) , 87-95
FLEXIBLE, WIRELESS, INDUCTIVELY COUPLED SURFACE COIL RESONATOR FOR EPR TOOTH DOSIMETRY
Managing radiation injuries following a catastrophic event where large numbers of people may have been exposed to life-threatening doses of ionizing radiation relies on the availability of biodosimetry to assess whether individuals need to be triaged for care. Electron Paramagnetic Resonance (EPR) tooth dosimetry is a viable method to accurately estimate the amount of ionizing radiation to which an individual has been exposed. In the intended measurement conditions and scenario, it is essential that the measurement process be fast, straightforward and provides meaningful and accurate dose estimations for individuals in the expected measurement conditions. The sensing component of a conventional L-band EPR spectrometer used for tooth dosimetry typically consists of a surface coil resonator that is rigidly, physically attached to the coupler. This design can result in cumbersome operation, limitations in teeth geometries that may be measured and hinder the overall utility of the dosimeter. A novel surface coil resonator has been developed for the currently existing L-band (1.15 GHz) EPR tooth dosimeter for the intended use as a point of care device by minimally trained operators. This resonator development provides further utility to the dosimeter, and increases the usability of the dosimeter by non-expert operators in the intended use scenario.