Antoon T. M. Willemsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Antoon T. M. Willemsen has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Andor W. J. M. Glaudemans
Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
3 shared publications - Riemer H. J. A. Slart
Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, Groningen, the Netherlands
2 shared publications - Rudi A. J. O. Dierckx
University of Groningen, University Medical Center Groningen
2 shared publications - Adriaan A. Lammertsma
University Medical Center Groningen, University of Groningen
1 shared publication - Adrienne H. Brouwers
Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
1 shared publication - Andreas Otte
Peter Osypka Institute of Medical Engineering, Department of Electrical Engineering, Medical Engineering and Computer Science, Offenburg University, Badstr. 24, D-77652 Offenburg, Germany
1 shared publication
Latest Publications
- Open Access
Current and Future Use of Long Axial Field-of-View Positron Emission Tomography/Computed Tomography Scanners in Clinical Oncology
The latest technical development in the field of positron emission tomography/computed tomography (PET/CT) imaging has been the extension of the PET axial field-of-view. As a result of the increased number of detectors, the long axial field-of-view (LAFOV) PET systems are not only characterized by a larger anatomical coverage but also by a substantially improved sensitivity, compared with conventional short axial field-of-view PET systems. In clinical practice, this innovation has led to the following optimization: (1) improved overall image quality, (2) decreased duration of PET examinations, (3) decreased amount of radioactivity administered to the patient, or (4) a combination of any of the above. In this review, novel applications of LAFOV PET in oncology are highlighted and future directions are discussed.
Open AccessCurrent and Future Use of Long Axial Field-of-View Positron Emission Tomography/Computed Tomography Scanners in Clinical Oncology
The latest technical development in the field of positron emission tomography/computed tomography (PET/CT) imaging has been the extension of the PET axial field-of-view. As a result of the increased number of detectors, the long axial field-of-view (LAFOV) PET systems are not only characterized by a larger anatomical coverage but also by a substantially improved sensitivity, compared with conventional short axial field-of-view PET systems. In clinical practice, this innovation has led to the following optimization: (1) improved overall image quality, (2) decreased duration of PET examinations, (3) decreased amount of radioactivity administered to the patient, or (4) a combination of any of the above. In this review, novel applications of LAFOV PET in oncology are highlighted and future directions are discussed.
- Open Access
- 30 October 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (11) , 2019
Analyzing the Estrogen Receptor Status of Liver Metastases with [18F]-FES-PET in Patients with Breast Cancer
Background: Positron emission tomography (PET) with 16α-[18F]-fluoro-17β-estradiol ([18F]-FES) can visualize estrogen receptor (ER) expression, but it is challenging to determine the ER status of liver metastases, due to high physiological [18F]-FES uptake. We evaluated whether [18F]-FES-PET can be used to determine the ER status of liver metastases, using corresponding liver biopsies as the gold standard. Methods: Patients with metastatic breast cancer (n = 23) were included if they had undergone a [18F]-FES-PET, liver metastasis biopsy, CT-scan, and [18F]-FDG-PET. [18F]-FES-PET scans were assessed by visual and quantitative analysis, tracer uptake was correlated with ER expression measured by immunohistochemical staining and the effects of region-of-interest size and background correction were determined. Results: Visual analysis allowed ER assessment of liver metastases with 100% specificity and 18% sensitivity. Quantitative analysis improved the sensitivity. Reduction of the region-of-interest size did not further improve the results, but background correction improved ER assessment, resulting in 83% specificity and 77% sensitivity. Using separate thresholds for ER+ and ER− metastases, positive and negative predictive values of 100% and 75%, respectively, could be obtained, although 30% of metastases remained inconclusive. Conclusion: In the majority of liver metastases, ER status can be determined with [18F]-FES-PET if background correction and separate thresholds are applied.
- 30 October 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (11) , 2019
Open AccessAnalyzing the Estrogen Receptor Status of Liver Metastases with [18F]-FES-PET in Patients with Breast Cancer
Background: Positron emission tomography (PET) with 16α-[18F]-fluoro-17β-estradiol ([18F]-FES) can visualize estrogen receptor (ER) expression, but it is challenging to determine the ER status of liver metastases, due to high physiological [18F]-FES uptake. We evaluated whether [18F]-FES-PET can be used to determine the ER status of liver metastases, using corresponding liver biopsies as the gold standard. Methods: Patients with metastatic breast cancer (n = 23) were included if they had undergone a [18F]-FES-PET, liver metastasis biopsy, CT-scan, and [18F]-FDG-PET. [18F]-FES-PET scans were assessed by visual and quantitative analysis, tracer uptake was correlated with ER expression measured by immunohistochemical staining and the effects of region-of-interest size and background correction were determined. Results: Visual analysis allowed ER assessment of liver metastases with 100% specificity and 18% sensitivity. Quantitative analysis improved the sensitivity. Reduction of the region-of-interest size did not further improve the results, but background correction improved ER assessment, resulting in 83% specificity and 77% sensitivity. Using separate thresholds for ER+ and ER− metastases, positive and negative predictive values of 100% and 75%, respectively, could be obtained, although 30% of metastases remained inconclusive. Conclusion: In the majority of liver metastases, ER status can be determined with [18F]-FES-PET if background correction and separate thresholds are applied.
- Open Access
- 26 October 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (11) , 1986
Toward Reliable Uptake Metrics in Large Vessel Vasculitis Studies
The aim of this study is to investigate the influence of sex, age, fat mass, fasting blood glucose level (FBGL), and estimated glomerular filtration rate (eGFR) on blood pool activity in patients with large vessel vasculitis (LVV). Blood pool activity was measured in the superior caval vein using mean, maximum, and peak standardized uptake values corrected for body weight (SUVs) and lean body mass (SULs) in 41 fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) scans of LVV patients. Sex influence on the blood pool activity was assessed with t-tests, while linear correlation analyses were used for age, fat mass, FBGL, and eGFR. Significantly higher SUVs were found in women compared with men, whereas SULs were similar between sexes. In addition, higher fat mass was associated with increased SUVs (r = 0.56 to 0.65; all p < 0.001) in the blood pool, but no correlations were found between SULs and fat mass (r = −0.25 to −0.15; all p > 0.05). Lower eGFR was associated with a higher FDG blood pool activity for all uptake values. In FDG-PET/CT studies with LVV patients, we recommend using SUL over SUV, while caution is advised in interpreting SUV and SUL measures when patients have impaired kidney function.
- 26 October 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (11) , 1986
Open AccessToward Reliable Uptake Metrics in Large Vessel Vasculitis Studies
The aim of this study is to investigate the influence of sex, age, fat mass, fasting blood glucose level (FBGL), and estimated glomerular filtration rate (eGFR) on blood pool activity in patients with large vessel vasculitis (LVV). Blood pool activity was measured in the superior caval vein using mean, maximum, and peak standardized uptake values corrected for body weight (SUVs) and lean body mass (SULs) in 41 fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) scans of LVV patients. Sex influence on the blood pool activity was assessed with t-tests, while linear correlation analyses were used for age, fat mass, FBGL, and eGFR. Significantly higher SUVs were found in women compared with men, whereas SULs were similar between sexes. In addition, higher fat mass was associated with increased SUVs (r = 0.56 to 0.65; all p < 0.001) in the blood pool, but no correlations were found between SULs and fat mass (r = −0.25 to −0.15; all p > 0.05). Lower eGFR was associated with a higher FDG blood pool activity for all uptake values. In FDG-PET/CT studies with LVV patients, we recommend using SUL over SUV, while caution is advised in interpreting SUV and SUL measures when patients have impaired kidney function.
- 16 November 2016
- Published by Springer Nature
- p. 193-209
Technical Aspects of PET/CT Image Quality
- Open Access
- 1 August 2016
- Published by Elsevier in EBioMedicine
- Vol. 10, 249-257
Altered Regional Cerebral Blood Flow in Chronic Whiplash Associated Disorders
- 1 August 2016
- Published by Elsevier in EBioMedicine
- Vol. 10, 249-257
Open AccessAltered Regional Cerebral Blood Flow in Chronic Whiplash Associated Disorders
- Open Access
- 1 January 2013
- Published by Springer Nature in EJNMMI Research
- Vol. 3 (1) , 63
Optimized dose regimen for whole-body FDG-PET imaging
The European Association of Nuclear Medicine procedure guidelines for whole-body fluorodeoxyglucose positron-emission tomography (FDG-PET) scanning prescribe a dose proportional to the patient's body mass. However, clinical practice shows degraded image quality in obese patients indicating that using an FDG dose proportional to body mass does not overcome size-related degradation of the image quality. The aim of this study was to optimize the administered FDG dose as a function of the patient's body mass or a different patient-dependent parameter, providing whole-body FDG-PET images of a more constant quality. Using a linear relation between administered dose and body mass, FDG-PET imaging was performed on two PET/computed tomography scanners (Biograph TruePoint and Biograph mCT, Siemens). Image quality was assessed by the signal-to-noise ratio (SNR) in the liver in 102 patients with a body mass of 46 to 130 kg. Moreover, the best correlating patient-dependent parameter was derived, and an optimized FDG dose regimen was determined. This optimized dose regimen was validated on the Biograph TruePoint system in 42 new patients. Furthermore, this relation was verified by a simulation study, in which patients with different body masses were simulated with cylindrical phantoms. As expected, both PET systems showed a significant decrease in SNR with increasing patient's body mass when using a linear dosage. When image quality was fitted to the patient-dependent parameters, the fit with the patient's body mass had the highest R2. The optimized dose regimen was found to be Anew= c/t × m2, where m is the body mass, t is the acquisition time per bed position and c is a constant (depending on scanner type). Using this relation, SNR no longer varied with the patient's body mass. This quadratic relation between dose and body mass was confirmed by the simulation study. A quadratic relation between FDG dose and the patient's body mass is recommended. Both simulations and clinical observations confirm that image quality remains constant across patients when this quadratic dose regimen is used.
- 1 January 2013
- Published by Springer Nature in EJNMMI Research
- Vol. 3 (1) , 63
Open AccessOptimized dose regimen for whole-body FDG-PET imaging
The European Association of Nuclear Medicine procedure guidelines for whole-body fluorodeoxyglucose positron-emission tomography (FDG-PET) scanning prescribe a dose proportional to the patient's body mass. However, clinical practice shows degraded image quality in obese patients indicating that using an FDG dose proportional to body mass does not overcome size-related degradation of the image quality. The aim of this study was to optimize the administered FDG dose as a function of the patient's body mass or a different patient-dependent parameter, providing whole-body FDG-PET images of a more constant quality. Using a linear relation between administered dose and body mass, FDG-PET imaging was performed on two PET/computed tomography scanners (Biograph TruePoint and Biograph mCT, Siemens). Image quality was assessed by the signal-to-noise ratio (SNR) in the liver in 102 patients with a body mass of 46 to 130 kg. Moreover, the best correlating patient-dependent parameter was derived, and an optimized FDG dose regimen was determined. This optimized dose regimen was validated on the Biograph TruePoint system in 42 new patients. Furthermore, this relation was verified by a simulation study, in which patients with different body masses were simulated with cylindrical phantoms. As expected, both PET systems showed a significant decrease in SNR with increasing patient's body mass when using a linear dosage. When image quality was fitted to the patient-dependent parameters, the fit with the patient's body mass had the highest R2. The optimized dose regimen was found to be Anew= c/t × m2, where m is the body mass, t is the acquisition time per bed position and c is a constant (depending on scanner type). Using this relation, SNR no longer varied with the patient's body mass. This quadratic relation between dose and body mass was confirmed by the simulation study. A quadratic relation between FDG dose and the patient's body mass is recommended. Both simulations and clinical observations confirm that image quality remains constant across patients when this quadratic dose regimen is used.