Brian C. J. Moore
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Brian C. J. Moore has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Brian R. Glasberg
5 shared publicationsJosé I. Alcántara
Department of Experimental Psychology, University of Cambridge, Cambridge, UK
3 shared publications- Andrew J. Oxenham
Department of Psychology, University of Minnesota, Minneapolis, MN 55455, USA
2 shared publications Deborah A. Vickers
Department of Experimental Psychology, University of Cambridge, Downing Street, Cambridge CB2 3EB, England
2 shared publicationsThomas H. Stainsby
Department of Experimental Psychology, University of Cambridge, Downing Street, Cambridge CB2 3EB, UK
2 shared publicationsAleksander Sek
Institute of Acoustics, Adam Mickiewicz University, 85 Umultowska, 61-614 Poznan, Poland
1 shared publication
Latest Publications
- 1 April 2004
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 25 (2) , 98-116
Dead Regions in the Cochlea: Conceptual Foundations, Diagnosis, and Clinical Applications
Regions in the cochlea with no (or very few) functioning inner hair cells and/or neurons are called “dead regions”. This paper reviews the anatomical, physiological, and psychophysical foundations for the concept of dead regions. It then considers methods that have been used to diagnose dead regions, focusing particularly on psychophysical tuning curves and the test using threshold-equalizing noise. Problems and limitations of each approach are discussed. Applications of tests for diagnosing dead regions are described. These include: giving the client realistic expectation about the likely benefit of a hearing aid; guidance in the fitting of hearing aids; assessment of candidacy for cochlear implants; assessment of hearing loss for medico-legal applications. Finally, guidelines for implementation of the threshold-equalizing noise test in clinical practice are given.
- 1 April 2004
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 25 (2) , 98-116
Dead Regions in the Cochlea: Conceptual Foundations, Diagnosis, and Clinical Applications
Regions in the cochlea with no (or very few) functioning inner hair cells and/or neurons are called “dead regions”. This paper reviews the anatomical, physiological, and psychophysical foundations for the concept of dead regions. It then considers methods that have been used to diagnose dead regions, focusing particularly on psychophysical tuning curves and the test using threshold-equalizing noise. Problems and limitations of each approach are discussed. Applications of tests for diagnosing dead regions are described. These include: giving the client realistic expectation about the likely benefit of a hearing aid; guidance in the fitting of hearing aids; assessment of candidacy for cochlear implants; assessment of hearing loss for medico-legal applications. Finally, guidelines for implementation of the threshold-equalizing noise test in clinical practice are given.
- 12 March 2004
- Published by Elsevier in Hearing Research
- Vol. 192 (1-2) , 90-100
Effects of masker component phase on the forward masking produced by complex tones in normally hearing and hearing-impaired subjects
- 12 March 2004
- Published by Elsevier in Hearing Research
- Vol. 192 (1-2) , 90-100
Effects of masker component phase on the forward masking produced by complex tones in normally hearing and hearing-impaired subjects
- 1 February 2004
- Published by Elsevier in Hearing Research
- Vol. 188 (1-2) , 70-88
A revised model of loudness perception applied to cochlear hearing loss
- 1 February 2004
- Published by Elsevier in Hearing Research
- Vol. 188 (1-2) , 70-88
A revised model of loudness perception applied to cochlear hearing loss
- 1 January 2004
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 43 (7) , 399-409
The effect on speech intelligibility of varying compression time constants in a digital hearing aid.
The identification of nonsense syllables in quiet and in three types of background (babble, cafeteria and single female speaker) was measured using four hearing aid compression algorithms differing in attack and release time constants, and using linear amplification. The speech level was always 65 dB SPL. The compression algorithms, which were implemented in a Phonak Claro ITE hearing aid, were: (1) 'very fast'--the attack time was 8 ms and the release time was 32 ms, for all 20 channels; (2) 'slow-fast'--the attack and release times decreased from 500 ms for low frequencies to about lOOms for high frequencies; (3) 'fast-slow'-the attack and release times increased from about 50ms for low frequencies to 500 ms for high frequencies; and (4) 'slow + fast'-a very slow-acting gain control signal was combined with a fast-acting gain control signal, for each channel in a 10-channel system. Acoustical stimuli were presented monaurally via a circumaural headphone mounted over the hearing aid. The linear condition did not use the Claro aid; instead, the signal was digitally filtered to implement the Cambridge formula prior to delivery via the earphone. Five subjects with moderate sensorineural hearing loss were tested in a counter-balanced order across conditions. In quiet, performance was best for linear amplification and worst for the slow + fast algorithm. In the presence of background sounds, the highest scores were obtained with the linear-gain Cambridge formula implemented via headphones; a supplementary experiment suggested that this was due to the greater high-frequency gain resulting from the use of this formula. No significant differences were found between scores for the different compression algorithms. We conclude that the intelligibility of speech at a fixed level, presented in background sounds, is not markedly affected by rather substantial variations of the time constants in a multichannel compression system.
- 1 January 2004
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 43 (7) , 399-409
The effect on speech intelligibility of varying compression time constants in a digital hearing aid.
The identification of nonsense syllables in quiet and in three types of background (babble, cafeteria and single female speaker) was measured using four hearing aid compression algorithms differing in attack and release time constants, and using linear amplification. The speech level was always 65 dB SPL. The compression algorithms, which were implemented in a Phonak Claro ITE hearing aid, were: (1) 'very fast'--the attack time was 8 ms and the release time was 32 ms, for all 20 channels; (2) 'slow-fast'--the attack and release times decreased from 500 ms for low frequencies to about lOOms for high frequencies; (3) 'fast-slow'-the attack and release times increased from about 50ms for low frequencies to 500 ms for high frequencies; and (4) 'slow + fast'-a very slow-acting gain control signal was combined with a fast-acting gain control signal, for each channel in a 10-channel system. Acoustical stimuli were presented monaurally via a circumaural headphone mounted over the hearing aid. The linear condition did not use the Claro aid; instead, the signal was digitally filtered to implement the Cambridge formula prior to delivery via the earphone. Five subjects with moderate sensorineural hearing loss were tested in a counter-balanced order across conditions. In quiet, performance was best for linear amplification and worst for the slow + fast algorithm. In the presence of background sounds, the highest scores were obtained with the linear-gain Cambridge formula implemented via headphones; a supplementary experiment suggested that this was due to the greater high-frequency gain resulting from the use of this formula. No significant differences were found between scores for the different compression algorithms. We conclude that the intelligibility of speech at a fixed level, presented in background sounds, is not markedly affected by rather substantial variations of the time constants in a multichannel compression system.
- 18 July 2003
- Published by Elsevier in Hearing Research
- Vol. 182 (1-2) , 153-163
Discrimination of the fundamental frequency of complex tones with fixed and shifting spectral envelopes by normally hearing and hearing-impaired subjects
- 18 July 2003
- Published by Elsevier in Hearing Research
- Vol. 182 (1-2) , 153-163
Discrimination of the fundamental frequency of complex tones with fixed and shifting spectral envelopes by normally hearing and hearing-impaired subjects
- 1 July 2003
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 114 (1) , 408-419
Perceived naturalness of spectrally distorted speech and music
We determined how the perceived naturalness of music and speech (male and female talkers) signals was affected by various forms of linear filtering, some of which were intended to mimic the spectral “distortions” introduced by transducers such as microphones, loudspeakers, and earphones. The filters introduced spectral tilts and ripples of various types, variations in upper and lower cutoff frequency, and combinations of these. All of the differently filtered signals (168 conditions) were intermixed in random order within one block of trials. Levels were adjusted to give approximately equal loudness in all conditions. Listeners were required to judge the perceptual quality (naturalness) of the filtered signals on a scale from 1 to 10. For spectral ripples, perceived quality decreased with increasing ripple density up to 0.2 and with increasing ripple depth. Spectral tilts also degraded quality, and the effects were similar for positive and negative tilts. Ripples and/or tilts degraded quality more when they extended over a wide frequency range (87–6981 Hz) than when they extended over subranges. Low- and mid-frequency ranges were roughly equally important for music, but the mid-range was most important for speech. For music, the highest quality was obtained for the broadband signal (55–16 854 Hz). Increasing the lower cutoff frequency from 55 Hz resulted in a clear degradation of quality. There was also a distinct degradation as the upper cutoff frequency was decreased from 16 845 Hz. For speech, there was a marked degradation when the lower cutoff frequency was increased from 123 to 208 Hz and when the upper cutoff frequency was decreased from 10 869 Hz. Typical telephone bandwidth (313 to 3547 Hz) gave very poor quality.- 1 July 2003
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 114 (1) , 408-419
Perceived naturalness of spectrally distorted speech and music
We determined how the perceived naturalness of music and speech (male and female talkers) signals was affected by various forms of linear filtering, some of which were intended to mimic the spectral “distortions” introduced by transducers such as microphones, loudspeakers, and earphones. The filters introduced spectral tilts and ripples of various types, variations in upper and lower cutoff frequency, and combinations of these. All of the differently filtered signals (168 conditions) were intermixed in random order within one block of trials. Levels were adjusted to give approximately equal loudness in all conditions. Listeners were required to judge the perceptual quality (naturalness) of the filtered signals on a scale from 1 to 10. For spectral ripples, perceived quality decreased with increasing ripple density up to 0.2 and with increasing ripple depth. Spectral tilts also degraded quality, and the effects were similar for positive and negative tilts. Ripples and/or tilts degraded quality more when they extended over a wide frequency range (87–6981 Hz) than when they extended over subranges. Low- and mid-frequency ranges were roughly equally important for music, but the mid-range was most important for speech. For music, the highest quality was obtained for the broadband signal (55–16 854 Hz). Increasing the lower cutoff frequency from 55 Hz resulted in a clear degradation of quality. There was also a distinct degradation as the upper cutoff frequency was decreased from 16 845 Hz. For speech, there was a marked degradation when the lower cutoff frequency was increased from 123 to 208 Hz and when the upper cutoff frequency was decreased from 10 869 Hz. Typical telephone bandwidth (313 to 3547 Hz) gave very poor quality.- 1 March 2003
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 24 (2) , 243-254
Coding of Sounds in the Auditory System and Its Relevance to Signal Processing and Coding in Cochlear Implants
To review how the properties of sounds are “coded” in the normal auditory system and to discuss the extent to which cochlear implants can and do represent these codes. Data are taken from published studies of the response of the cochlea and auditory nerve to simple and complex stimuli, in both the normal and the electrically stimulated ear. The review describes: 1) the coding in the normal auditory system of overall level (which partly determines perceived loudness), spectral shape (which partly determines perceived timbre and the identity of speech sounds), periodicity (which partly determines pitch), and sound location; 2) the role of the active mechanism in the cochlea, and particularly the fast-acting compression associated with that mechanism; 3) the neural response patterns evoked by cochlear implants; and 4) how the response patterns evoked by implants differ from those observed in the normal auditory system in response to sound. A series of specific issues is then discussed, including: 1) how to compensate for the loss of cochlear compression; 2) the effective number of independent channels in a normal ear and in cochlear implantees; 3) the importance of independence of responses across neurons; 4) the stochastic nature of normal neural responses; 5) the possible role of across-channel coincidence detection; and 6) potential benefits of binaural implantation. Current cochlear implants do not adequately reproduce several aspects of the neural coding of sound in the normal auditory system. Improved electrode arrays and coding systems may lead to improved coding and, it is hoped, to better performance.
- 1 March 2003
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 24 (2) , 243-254
Coding of Sounds in the Auditory System and Its Relevance to Signal Processing and Coding in Cochlear Implants
To review how the properties of sounds are “coded” in the normal auditory system and to discuss the extent to which cochlear implants can and do represent these codes. Data are taken from published studies of the response of the cochlea and auditory nerve to simple and complex stimuli, in both the normal and the electrically stimulated ear. The review describes: 1) the coding in the normal auditory system of overall level (which partly determines perceived loudness), spectral shape (which partly determines perceived timbre and the identity of speech sounds), periodicity (which partly determines pitch), and sound location; 2) the role of the active mechanism in the cochlea, and particularly the fast-acting compression associated with that mechanism; 3) the neural response patterns evoked by cochlear implants; and 4) how the response patterns evoked by implants differ from those observed in the normal auditory system in response to sound. A series of specific issues is then discussed, including: 1) how to compensate for the loss of cochlear compression; 2) the effective number of independent channels in a normal ear and in cochlear implantees; 3) the importance of independence of responses across neurons; 4) the stochastic nature of normal neural responses; 5) the possible role of across-channel coincidence detection; and 6) potential benefits of binaural implantation. Current cochlear implants do not adequately reproduce several aspects of the neural coding of sound in the normal auditory system. Improved electrode arrays and coding systems may lead to improved coding and, it is hoped, to better performance.
- 1 January 2003
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 42 (8) , 465-474
Application of the TEN test to hearing-impaired teenagers with severe-to-profound hearing loss: Aplicación de la prueba TEN en adolescentes con hipoacusias severas a profundas
Hearing impairment is often associated with damage to the hair cells of the cochlea. An area of the cochlea with complete loss of function of inner hair cells is known as a 'dead region'. Dead regions can be identified by measuring detection thresholds for pure tones in quiet and in threshold-equalizing noise (TEN). So far, the TEN test has only been used to identify dead regions in adults with moderate-to-severe hearing impairment. The aim of this study was to assess problems in applying the TEN test to teenagers with longstanding severe-to-profound sensorineural hearing impairment, and to assess the prevalence of dead regions in this population. The subjects had a mean age of 14 years, and there were 13 females and 20 males. The stimuli for the TEN test were derived from a CD, whose output was routed via a GSI-16 audiometer and an amplifier to Sennheiser HD580 earphones. For each ear of each subject, both absolute thresholds and masked thresholds in the TEN were measured. For the majority of ears, the results were in-conclusive at some frequencies, due to the maximum output of the audiometer being reached when measuring the absolute or masked threshold. In almost all cases, the diagnosis was uncertain at some frequencies because the TEN could not be made sufficiently intense to produce significant masking. However, for 23 (70%) subjects, the criteria for a dead region at medium or high frequencies were met in at least one ear. For eight (35%) of these subjects, the criteria were only just met. Sixteen of the 24 subjects with a congenital hearing impairment, and four of the five subjects with an acquired impairment, met the criteria for a dead region. The results suggest that dead regions are relatively common among teenagers with a longstanding hearing impairment.
- 1 January 2003
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 42 (8) , 465-474
Application of the TEN test to hearing-impaired teenagers with severe-to-profound hearing loss: Aplicación de la prueba TEN en adolescentes con hipoacusias severas a profundas
Hearing impairment is often associated with damage to the hair cells of the cochlea. An area of the cochlea with complete loss of function of inner hair cells is known as a 'dead region'. Dead regions can be identified by measuring detection thresholds for pure tones in quiet and in threshold-equalizing noise (TEN). So far, the TEN test has only been used to identify dead regions in adults with moderate-to-severe hearing impairment. The aim of this study was to assess problems in applying the TEN test to teenagers with longstanding severe-to-profound sensorineural hearing impairment, and to assess the prevalence of dead regions in this population. The subjects had a mean age of 14 years, and there were 13 females and 20 males. The stimuli for the TEN test were derived from a CD, whose output was routed via a GSI-16 audiometer and an amplifier to Sennheiser HD580 earphones. For each ear of each subject, both absolute thresholds and masked thresholds in the TEN were measured. For the majority of ears, the results were in-conclusive at some frequencies, due to the maximum output of the audiometer being reached when measuring the absolute or masked threshold. In almost all cases, the diagnosis was uncertain at some frequencies because the TEN could not be made sufficiently intense to produce significant masking. However, for 23 (70%) subjects, the criteria for a dead region at medium or high frequencies were met in at least one ear. For eight (35%) of these subjects, the criteria were only just met. Sixteen of the 24 subjects with a congenital hearing impairment, and four of the five subjects with an acquired impairment, met the criteria for a dead region. The results suggest that dead regions are relatively common among teenagers with a longstanding hearing impairment.
- 8 November 2002
- Published by Elsevier in Hearing Research
- Vol. 175 (1-2) , 66-74
Behavioural measurement of level-dependent shifts in the vibration pattern on the basilar membrane at 1 and 2 kHz
- 8 November 2002
- Published by Elsevier in Hearing Research
- Vol. 175 (1-2) , 66-74
Behavioural measurement of level-dependent shifts in the vibration pattern on the basilar membrane at 1 and 2 kHz