Devendra Tolani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Devendra Tolani has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Brooke N. Klatt
University of Pittsburgh
2 shared publications - Lisa Scott Holt
BlueHalo, an AV Company, Germantown, MD 20876, USA
2 shared publications - Pedram Hovareshti
BlueHalo, an AV Company, Germantown, MD 20876, United States
2 shared publications - Susan L. Whitney
University of Pittsburgh
2 shared publications - Chad Zalkin
BlueHalo, Rockville, MD, United States
1 shared publication - Chad Zalkin
NxtHealth Team, Intelligent Automation, Rockville, MD 20855, USA
1 shared publication
Latest Publications
- Open Access
- 4 February 2025
- Published by JMIR Publications Inc. in JMIR Rehabilitation and Assistive Technologies
- Vol. 12 (1) , e58713
A Tablet-Based Technology for Objective Exercise Monitoring in Vestibular Rehabilitation: Mixed Methods Study
Background: A low-cost home exercise system called VestAid has been developed to assist participants during vestibulo-ocular reflex gaze stabilization exercises outside of clinic visits. The system includes a tablet-based app for the participant and a web-based portal for the physical therapist that provides data to make judgments about exercise accuracy and performance. Objective: The purpose of this study was to assess the feasibility and acceptability of VestAid in a pilot study of 10 participants (mean age 45 [SD 19] years; 6 women) with various vestibular diagnoses. Methods: All participants completed twelve 30-second horizontal vestibulo-ocular reflex exercises in a seated position (6 “easy” and 6 “hard” exercises). The exercises differed by variations in the background color, pattern, and movement. One of the exercises was repeated to assess the test-retest reliability of the measure of gaze stability accuracy and head motion compliance during the exercise. Participants rated the difficulty of the exercises (0‐10 where 0=easy, 10=difficult) and completed usability surveys. Results: Participants completed the VestAid session without adverse events. The responses from the usability survey demonstrate the acceptability of VestAid. The mean rating of the “easy” exercises was 2.7/10 (SD 1.9). The mean rating for the “difficult” exercises across participants was 4.8/10 (SD 2.1). Conclusions: The consistency of the mean ratings of the participants with the exercise classifications (“easy” and “difficult”) suggests that VestAid has clinical utility.
- 4 February 2025
- Published by JMIR Publications Inc. in JMIR Rehabilitation and Assistive Technologies
- Vol. 12 (1) , e58713
Open AccessA Tablet-Based Technology for Objective Exercise Monitoring in Vestibular Rehabilitation: Mixed Methods Study
Background: A low-cost home exercise system called VestAid has been developed to assist participants during vestibulo-ocular reflex gaze stabilization exercises outside of clinic visits. The system includes a tablet-based app for the participant and a web-based portal for the physical therapist that provides data to make judgments about exercise accuracy and performance. Objective: The purpose of this study was to assess the feasibility and acceptability of VestAid in a pilot study of 10 participants (mean age 45 [SD 19] years; 6 women) with various vestibular diagnoses. Methods: All participants completed twelve 30-second horizontal vestibulo-ocular reflex exercises in a seated position (6 “easy” and 6 “hard” exercises). The exercises differed by variations in the background color, pattern, and movement. One of the exercises was repeated to assess the test-retest reliability of the measure of gaze stability accuracy and head motion compliance during the exercise. Participants rated the difficulty of the exercises (0‐10 where 0=easy, 10=difficult) and completed usability surveys. Results: Participants completed the VestAid session without adverse events. The responses from the usability survey demonstrate the acceptability of VestAid. The mean rating of the “easy” exercises was 2.7/10 (SD 1.9). The mean rating for the “difficult” exercises across participants was 4.8/10 (SD 2.1). Conclusions: The consistency of the mean ratings of the participants with the exercise classifications (“easy” and “difficult”) suggests that VestAid has clinical utility.
- Open Access
VestAid: A Tablet-Based Technology for Objective Exercise Monitoring in Vestibular Rehabilitation
(1) Background: Current vestibular rehabilitation therapy is an exercise-based approach aimed at promoting gaze stability, habituating symptoms, and improving balance and walking in patients with mild traumatic brain injury (mTBI). A major component of these exercises is the adaptation of the vestibulo-ocular reflex (VOR) and habituation training. Due to acute injury, the gain of the VOR is usually reduced, resulting in eye movement velocity that is less than head movement velocity. There is a higher chance for the success of the therapy program if the patient (a) understands the exercise procedure, (b) performs the exercises according to the prescribed regimen, (c) reports pre- and post-exercise symptoms and perceived difficulty, and (d) gets feedback on performance. (2) Methods: The development and laboratory evaluation of VestAid, an innovative, low-cost, tablet-based system that helps patients perform vestibulo-ocular reflex (VORx1) exercises correctly at home without therapist guidance, is presented. VestAid uses the tablet camera to automatically assess patient performance and compliance with exercise parameters. The system provides physical therapists (PTs) with near real-time, objective (head speed and gaze fixation compliance), and subjective (perceived difficulty and pre- and post- exercise symptoms) metrics through a web-based provider portal. The accuracy of the head-angle and eye-gaze compliance metrics was evaluated. The accuracy of estimated head angles calculated via VestAid’s low-complexity algorithms was compared to the state-of-the-art deep-learning method on a public dataset. The accuracy of VestAid’s metric evaluation during the VORx1 exercises was assessed in comparison to the output of an inertial measurement unit (IMU)-based system. (3) Results: There are low mean interpeak time errors (consistently below 0.1 s) across all speeds of the VORx1 exercise, as well as consistently matching numbers of identified peaks. The spatial comparison (after adjusting for the lag measured with the cross-correlation) between the VestAid and IMU-based systems also shows good matching, as shown by the low mean absolute head angle error, in which for all speeds, the mean is less than 10 degrees. (4) Conclusions: The accuracy of the system is sufficient to provide therapists with a good assessment of patient performance. While the VestAid system’s head pose evaluation model may not be perfectly accurate as a result of the occluded facial features when the head moves further towards an extreme in pitch and yaw, the head speed measurements and associated compliance measures are sufficiently accurate for monitoring patients’ VORx1 exercise compliance and general performance.
Open AccessVestAid: A Tablet-Based Technology for Objective Exercise Monitoring in Vestibular Rehabilitation
(1) Background: Current vestibular rehabilitation therapy is an exercise-based approach aimed at promoting gaze stability, habituating symptoms, and improving balance and walking in patients with mild traumatic brain injury (mTBI). A major component of these exercises is the adaptation of the vestibulo-ocular reflex (VOR) and habituation training. Due to acute injury, the gain of the VOR is usually reduced, resulting in eye movement velocity that is less than head movement velocity. There is a higher chance for the success of the therapy program if the patient (a) understands the exercise procedure, (b) performs the exercises according to the prescribed regimen, (c) reports pre- and post-exercise symptoms and perceived difficulty, and (d) gets feedback on performance. (2) Methods: The development and laboratory evaluation of VestAid, an innovative, low-cost, tablet-based system that helps patients perform vestibulo-ocular reflex (VORx1) exercises correctly at home without therapist guidance, is presented. VestAid uses the tablet camera to automatically assess patient performance and compliance with exercise parameters. The system provides physical therapists (PTs) with near real-time, objective (head speed and gaze fixation compliance), and subjective (perceived difficulty and pre- and post- exercise symptoms) metrics through a web-based provider portal. The accuracy of the head-angle and eye-gaze compliance metrics was evaluated. The accuracy of estimated head angles calculated via VestAid’s low-complexity algorithms was compared to the state-of-the-art deep-learning method on a public dataset. The accuracy of VestAid’s metric evaluation during the VORx1 exercises was assessed in comparison to the output of an inertial measurement unit (IMU)-based system. (3) Results: There are low mean interpeak time errors (consistently below 0.1 s) across all speeds of the VORx1 exercise, as well as consistently matching numbers of identified peaks. The spatial comparison (after adjusting for the lag measured with the cross-correlation) between the VestAid and IMU-based systems also shows good matching, as shown by the low mean absolute head angle error, in which for all speeds, the mean is less than 10 degrees. (4) Conclusions: The accuracy of the system is sufficient to provide therapists with a good assessment of patient performance. While the VestAid system’s head pose evaluation model may not be perfectly accurate as a result of the occluded facial features when the head moves further towards an extreme in pitch and yaw, the head speed measurements and associated compliance measures are sufficiently accurate for monitoring patients’ VORx1 exercise compliance and general performance.
- 1 December 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Transportation Engineering
- Vol. 142 (12)
Design and Predeployment Assessment of an Integrated Intersection Dilemma Zone Protection System
Despite the fact that both traffic researchers and highway agencies have devoted considerable efforts over the past few decades to improving intersection safety, the development of effective strategies remains a challenging task. This research presents an integrated dilemma zone protection system (DZPS) for contending with the safety issues caused by the presence of a dilemma zone, a primary factor contributing to the rear-end collisions or side-angle crashes at intersections, especially at those experiencing high-speed traffic flows. The entire paper includes three parts: (1) development of an integrated system for protecting vehicles within the dilemma zone; (2) procedures to calibrate those key system parameters with field data at a candidate intersection; and (3) design of a per-deployment assessment process for evaluating such a design prior to its field deployment. The proposed DZPS, developed with a target intersection’s traffic characteristic data and geometric constraints, consists of thr...
- 1 December 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Transportation Engineering
- Vol. 142 (12)
Design and Predeployment Assessment of an Integrated Intersection Dilemma Zone Protection System
Despite the fact that both traffic researchers and highway agencies have devoted considerable efforts over the past few decades to improving intersection safety, the development of effective strategies remains a challenging task. This research presents an integrated dilemma zone protection system (DZPS) for contending with the safety issues caused by the presence of a dilemma zone, a primary factor contributing to the rear-end collisions or side-angle crashes at intersections, especially at those experiencing high-speed traffic flows. The entire paper includes three parts: (1) development of an integrated system for protecting vehicles within the dilemma zone; (2) procedures to calibrate those key system parameters with field data at a candidate intersection; and (3) design of a per-deployment assessment process for evaluating such a design prior to its field deployment. The proposed DZPS, developed with a target intersection’s traffic characteristic data and geometric constraints, consists of thr...