Laurens W. Wollersheim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Laurens W. Wollersheim has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Ad F. T. M. Verhagen
Department of Cardiothoracic Surgery, Radboud University Medical Center, Nijmegen, The Netherlands
1 shared publication Ad F. Verhagen
Department of Cardiothoracic Surgery, Radboudumc, Nijmegen, Geert Grooteplein Zuid 10, 6525 GA Nijmegen, the Netherlands
1 shared publicationFoeke J.H. Nauta
Department of Cardiac Surgery, Brigham and Women's Hospital, Boston, MA USA
1 shared publicationGregory S. Couper
Department of Cardiac Surgery, Brigham and Women's Hospital, Boston, MA USA
1 shared publicationH Dieker
Radboud University Medical Center, Cardiology , Nijmegen , The Netherlands
1 shared publicationLawrence H. Cohn
Department of Cardiac Surgery, Brigham and Women's Hospital, Boston, MA USA
1 shared publication
Latest Publications
- Open Access
- 1 October 2022
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 43 (Supplement)
Exploring variations in current clinical practice regarding postoperative pericardial effusion: a questionnaire study
Background: Postoperative pericardial effusion (PPE) is a frequently occurring event after cardiac surgery, potentially leading to life-threatening cardiac tamponade. Unfortunately, no guidelines are currently available on this subject, possibly leading to unwarranted variations in care in clinical practice. Purpose: The goal of our study was to determine the diagnostic and therapeutic preferences of cardiologists and cardiothoracic surgeons in the Netherlands regarding PPE, and to evaluate possible variations in this matter between specialties and centers. Methods: A web-based questionnaire was sent to all interventional cardiologists and cardiothoracic surgeons in the Netherlands. Diagnostic preferences for the evaluation of PPE were examined. Additionally, clinical preferences were explored in response to 4 patient scenarios with each illustrating a combination of either high or low clinical suspicion of cardiac tamponade and either high or low echocardiographic suspicion. Each scenario was also stratified by 3 different amounts of PPE (2cm), leading to a total of 12 fictional patient cases (Figure 1). Results: From 27 of the 31 contacted centers, a total of 94 clinicians responded to the survey, of whom 46 interventional cardiologists and 48 cardiothoracic surgeons. Cardiologists were more in favor of routine postoperative echocardiography in all patients (44%), whereas cardiothoracic surgeons preferred routine imaging after specific procedures, especially after mitral (85%) and tricuspid (79%) valve surgery. Overall, drainage of PPE (>48 hours postoperatively) was preferred through pericardiocentesis (83%) instead of surgical evacuation (17%). Regarding the patient scenarios, cardiothoracic surgeons were significantly more inclined to evacuate PPE compared to cardiologists for all scenarios combined (51% vs 37%, p<0.001) (Figure 1). In addition, evacuation was overall significantly more preferred by cardiologists employed in surgical centers when compared to those working in non-surgical centers (43% vs 31%, p=0.02). Results from the interrater agreement analysis of groups of clinicians working in the same center varied from very poor up to very good (kappa value of 0.22–0.67), suggesting existing variation of PPE treatment preferences even within one center. Conclusions: Our study highlights the significant variation of preferences in contemporary PPE management between cardiothoracic surgeons and interventional cardiologists in the Netherlands, sometimes even within the same center. These findings are the possible consequences of a current lack of general recommendations or guidelines. This could lead to unwarranted variation in care and additional research is necessary to provide general recommendations. Funding Acknowledgement: Type of funding sources: None.
- 1 October 2022
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 43 (Supplement)
Open AccessExploring variations in current clinical practice regarding postoperative pericardial effusion: a questionnaire study
Background: Postoperative pericardial effusion (PPE) is a frequently occurring event after cardiac surgery, potentially leading to life-threatening cardiac tamponade. Unfortunately, no guidelines are currently available on this subject, possibly leading to unwarranted variations in care in clinical practice. Purpose: The goal of our study was to determine the diagnostic and therapeutic preferences of cardiologists and cardiothoracic surgeons in the Netherlands regarding PPE, and to evaluate possible variations in this matter between specialties and centers. Methods: A web-based questionnaire was sent to all interventional cardiologists and cardiothoracic surgeons in the Netherlands. Diagnostic preferences for the evaluation of PPE were examined. Additionally, clinical preferences were explored in response to 4 patient scenarios with each illustrating a combination of either high or low clinical suspicion of cardiac tamponade and either high or low echocardiographic suspicion. Each scenario was also stratified by 3 different amounts of PPE (2cm), leading to a total of 12 fictional patient cases (Figure 1). Results: From 27 of the 31 contacted centers, a total of 94 clinicians responded to the survey, of whom 46 interventional cardiologists and 48 cardiothoracic surgeons. Cardiologists were more in favor of routine postoperative echocardiography in all patients (44%), whereas cardiothoracic surgeons preferred routine imaging after specific procedures, especially after mitral (85%) and tricuspid (79%) valve surgery. Overall, drainage of PPE (>48 hours postoperatively) was preferred through pericardiocentesis (83%) instead of surgical evacuation (17%). Regarding the patient scenarios, cardiothoracic surgeons were significantly more inclined to evacuate PPE compared to cardiologists for all scenarios combined (51% vs 37%, p<0.001) (Figure 1). In addition, evacuation was overall significantly more preferred by cardiologists employed in surgical centers when compared to those working in non-surgical centers (43% vs 31%, p=0.02). Results from the interrater agreement analysis of groups of clinicians working in the same center varied from very poor up to very good (kappa value of 0.22–0.67), suggesting existing variation of PPE treatment preferences even within one center. Conclusions: Our study highlights the significant variation of preferences in contemporary PPE management between cardiothoracic surgeons and interventional cardiologists in the Netherlands, sometimes even within the same center. These findings are the possible consequences of a current lack of general recommendations or guidelines. This could lead to unwarranted variation in care and additional research is necessary to provide general recommendations. Funding Acknowledgement: Type of funding sources: None.
- Open Access
- 1 February 2021
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 5 (2) , ytab026
Giant sinus of Valsalva aneurysm—a peculiar presentation with atrial fibrillation
A 73-year-old woman presented with a transient ischaemic attack and paroxysmal atrial fibrillation (electrocardiogram as supplementary image). Her premedical history included hypertension, and mild obesity (body mass index 27), yielding a CHA2DS2-VASc score of 5 point (female gender, hypertension, age >65 years, transient ischaemic attack). Transthoracic echocardiography revealed a large mass protruding into both atria, which appeared to originate from the aortic root (Panels A and B). The aortic valve was tricuspid and had trivial insufficiency. Computed tomography confirmed the presence of an aneurysm (maximal diameter 62 mm) originating from the non-coronary sinus of Valsalva, bulging into both atria ( Supplementary material online , Figure). We hypothesized that the mechanical pressure of the aneurysm against the atrial wall caused structural atrial remodelling and elevation of atrial filling pressures, which could have triggered the arrhythmia. These underlying pathophysiologic causes were previously described by Andrade et al. and Pritchett et al. Because of the size of the aneurysm, the patient was scheduled for surgery. After median sternotomy and cannulation for extracorporeal circulation, the heart was arrested and the aortic root was opened. A large, thin-walled aneurysmal sac originating from the non-coronary sinus (Panels C and D) was seen. Also, the left- and right-coronary sinus appeared friable. The left-coronary leaflet was calcified. Because of this, and considering the age of the patient, valve-sparing root replacement seemed inappropriate. We performed a Bentall procedure implanting a biological composite conduit. Patient was weaned from cardiopulmonary bypass in sinus rhythm. The procedure and post-operative course were uncomplicated. She was discharged with a vitamin K antagonist and could be switched to direct anticoagulation therapy after 3 months.
- 1 February 2021
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 5 (2) , ytab026
Open AccessGiant sinus of Valsalva aneurysm—a peculiar presentation with atrial fibrillation
A 73-year-old woman presented with a transient ischaemic attack and paroxysmal atrial fibrillation (electrocardiogram as supplementary image). Her premedical history included hypertension, and mild obesity (body mass index 27), yielding a CHA2DS2-VASc score of 5 point (female gender, hypertension, age >65 years, transient ischaemic attack). Transthoracic echocardiography revealed a large mass protruding into both atria, which appeared to originate from the aortic root (Panels A and B). The aortic valve was tricuspid and had trivial insufficiency. Computed tomography confirmed the presence of an aneurysm (maximal diameter 62 mm) originating from the non-coronary sinus of Valsalva, bulging into both atria ( Supplementary material online , Figure). We hypothesized that the mechanical pressure of the aneurysm against the atrial wall caused structural atrial remodelling and elevation of atrial filling pressures, which could have triggered the arrhythmia. These underlying pathophysiologic causes were previously described by Andrade et al. and Pritchett et al. Because of the size of the aneurysm, the patient was scheduled for surgery. After median sternotomy and cannulation for extracorporeal circulation, the heart was arrested and the aortic root was opened. A large, thin-walled aneurysmal sac originating from the non-coronary sinus (Panels C and D) was seen. Also, the left- and right-coronary sinus appeared friable. The left-coronary leaflet was calcified. Because of this, and considering the age of the patient, valve-sparing root replacement seemed inappropriate. We performed a Bentall procedure implanting a biological composite conduit. Patient was weaned from cardiopulmonary bypass in sinus rhythm. The procedure and post-operative course were uncomplicated. She was discharged with a vitamin K antagonist and could be switched to direct anticoagulation therapy after 3 months.
- 1 August 2016
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 102 (2) , 676
Nineteen-Millimeter Bioprostheses: When Is “Good” Not Good Enough?
- 1 August 2016
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 102 (2) , 676
Nineteen-Millimeter Bioprostheses: When Is “Good” Not Good Enough?
- 1 September 2012
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 7 (5) , 368-371
Minimal-Access Aortic Valve Replacement with Concomitant Aortic Procedure: A 9-Year Experience
Objective: Minimal-access approaches through upper hemisternotomy is an established technique for aortic valve replacement (AVR) and aortic surgery in our institution. We assessed the outcome of undergoing AVR with concomitant aortic surgery through upper hemisternotomy. Methods: We retrospectively reviewed 109 patients from January 2002 to May 2011 who had AVR with concomitant aortic surgery through upper hemisternotomy. Aortic valve replacement with supra-coronary ascending aortic replacement was performed in 65 patients; AVR with ascending and proximal arch replacement, in 8 patients; AVR with aortoplasty, in 11 patients; Bentall procedure, in 8 patients; and AVR with root enlargement, in 13 patients. In-hospital outcomes and 1- and 5-year survival were examined. Results: The mean age was 58.5 years (range, 23–89 years); 41.3% of patients had bicuspid aortic valve (n = 45). Of the patients, 82.6% had true aneurysm (n = 90), 2.8% had calcified aorta (n = 3), 8.3% had small annulus (n = 9), and 3.7% had calcified annulus (n = 4). There were 6 (5.5%) reoperations and 15 (13.8%) urgent cases. Mean perfusion time was 152 ± 61 minutes, and cross-clamp time was 108 ± 47 minutes. Nine cases were performed with deep hypothermic circulatory arrest (8.3%). Operative mortality was 2.8% (n = 3). There were 4 (3.7%) cases with reoperation for bleeding, 2 (1.8%) myocardial infarctions, and 2 (1.8%) new-onset renal failure. Mean length of stay was 7.1 ± 5.6 days. Kaplan-Meier analysis showed that 1-year postoperative survival was 96.2% and 5-year survival was 92.4%. Conclusions: An upper hemisternotomy approach is safe and feasible for AVR and concomitant aortic surgery with good early and midterm outcomes. This approach is also associated with low morbidity rate and short length of stay.
- 1 September 2012
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 7 (5) , 368-371
Minimal-Access Aortic Valve Replacement with Concomitant Aortic Procedure: A 9-Year Experience
Objective: Minimal-access approaches through upper hemisternotomy is an established technique for aortic valve replacement (AVR) and aortic surgery in our institution. We assessed the outcome of undergoing AVR with concomitant aortic surgery through upper hemisternotomy. Methods: We retrospectively reviewed 109 patients from January 2002 to May 2011 who had AVR with concomitant aortic surgery through upper hemisternotomy. Aortic valve replacement with supra-coronary ascending aortic replacement was performed in 65 patients; AVR with ascending and proximal arch replacement, in 8 patients; AVR with aortoplasty, in 11 patients; Bentall procedure, in 8 patients; and AVR with root enlargement, in 13 patients. In-hospital outcomes and 1- and 5-year survival were examined. Results: The mean age was 58.5 years (range, 23–89 years); 41.3% of patients had bicuspid aortic valve (n = 45). Of the patients, 82.6% had true aneurysm (n = 90), 2.8% had calcified aorta (n = 3), 8.3% had small annulus (n = 9), and 3.7% had calcified annulus (n = 4). There were 6 (5.5%) reoperations and 15 (13.8%) urgent cases. Mean perfusion time was 152 ± 61 minutes, and cross-clamp time was 108 ± 47 minutes. Nine cases were performed with deep hypothermic circulatory arrest (8.3%). Operative mortality was 2.8% (n = 3). There were 4 (3.7%) cases with reoperation for bleeding, 2 (1.8%) myocardial infarctions, and 2 (1.8%) new-onset renal failure. Mean length of stay was 7.1 ± 5.6 days. Kaplan-Meier analysis showed that 1-year postoperative survival was 96.2% and 5-year survival was 92.4%. Conclusions: An upper hemisternotomy approach is safe and feasible for AVR and concomitant aortic surgery with good early and midterm outcomes. This approach is also associated with low morbidity rate and short length of stay.