Bambang Agus Kironoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bambang Agus Kironoto has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
A D Nanda
Universitas Gadjah Mada
2 shared publications- Achmad Rafi’UD Darajat
1) Department of Civil and Environmental Engineering, Faculty of Engineering, Universitas Gadjah Mada, Yogyakarta, Indonesia. 2) Department of Civil Engineering, Faculty of Engineering, Universitas Tidar, Magelang, Indonesia
2 shared publications - Djoko Legono
Universitas Gadjah Mada
2 shared publications - Istiarto2 shared publications
R Jayadi
Universitas Gadjah Mada
2 shared publicationsAdam Pamudji Rahardjo
1 shared publication
Latest Publications
- Open Access
- 1 October 2026
- Published by KEAI Publishing in International Journal of Sediment Research
- Vol. 41 (5) , 727-747
3D velocity structure and Reynolds shear stress around an oblong pier under clear-water and live-bed conditions
- 1 October 2026
- Published by KEAI Publishing in International Journal of Sediment Research
- Vol. 41 (5) , 727-747
Open Access3D velocity structure and Reynolds shear stress around an oblong pier under clear-water and live-bed conditions
- Open Access
- 1 May 2026
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 1631 (1)
Evaluation of Water Management Performance with Automatic Valve Gates in Block A5 of the Dadahup Swamp Irrigation Area
Block A5 of the Dadahup Swamp Irrigation Area (DIR) in Kapuas Regency, Central Kalimantan, functions as a representative model for water management in the region. This block plays a vital role in maintaining the productivity of swamp-based agriculture. Fluctuations in water levels influenced by tides and uneven flow distribution cause irrigation management performance to be suboptimal. This study aims to assess the operational performance of water regulation in Block A5 after the implementation of automatic valve gates designed to improve flow regulation efficiency. Hydraulic simulations were carried out using HEC-RAS software, focusing on discharge variations, water surface profiles, and hydraulic responses to the integration of automatic valve gates. Comparative analyses were performed between the existing (manual) condition and the automated valve gate scenario. The findings show that the use of automatic valve gates contributes to improved irrigation efficiency by minimizing flood potential and stabilizing water levels across the network. The use of automatic valve gates can reduce the maximum water level by around 0.01 to 0.03 meters in tertiary and quaternary channels, while maximum flow decreased by approximately 0.01–0.93 m 3 /s in tertiary and 0.01–0.16 m 3 /s in quaternary channels. Overall, the implementation of automatic valve gates enhances flow stability, lowers peak discharge, and promotes more effective water management in swamp irrigation systems. Consequently, this technology offers a promising approach for mitigating excessive discharge, minimizing channel erosion risks, and improving equitable water distribution among irrigation plots.
- 1 May 2026
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 1631 (1)
Open AccessEvaluation of Water Management Performance with Automatic Valve Gates in Block A5 of the Dadahup Swamp Irrigation Area
Block A5 of the Dadahup Swamp Irrigation Area (DIR) in Kapuas Regency, Central Kalimantan, functions as a representative model for water management in the region. This block plays a vital role in maintaining the productivity of swamp-based agriculture. Fluctuations in water levels influenced by tides and uneven flow distribution cause irrigation management performance to be suboptimal. This study aims to assess the operational performance of water regulation in Block A5 after the implementation of automatic valve gates designed to improve flow regulation efficiency. Hydraulic simulations were carried out using HEC-RAS software, focusing on discharge variations, water surface profiles, and hydraulic responses to the integration of automatic valve gates. Comparative analyses were performed between the existing (manual) condition and the automated valve gate scenario. The findings show that the use of automatic valve gates contributes to improved irrigation efficiency by minimizing flood potential and stabilizing water levels across the network. The use of automatic valve gates can reduce the maximum water level by around 0.01 to 0.03 meters in tertiary and quaternary channels, while maximum flow decreased by approximately 0.01–0.93 m 3 /s in tertiary and 0.01–0.16 m 3 /s in quaternary channels. Overall, the implementation of automatic valve gates enhances flow stability, lowers peak discharge, and promotes more effective water management in swamp irrigation systems. Consequently, this technology offers a promising approach for mitigating excessive discharge, minimizing channel erosion risks, and improving equitable water distribution among irrigation plots.
- Open Access
- 1 March 2026
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 1593 (1)
Effectiveness Study of Water Control Structures Rehabilitation in Dadahup Swamp Irrigation Area, Central Kalimantan
The Dadahup Swamp Irrigation Area (DIR), located in the Dadahup and Kapuas Murung Subdistricts of Kapuas Regency, Central Kalimantan, encompasses 21,226 hectares of agricultural land. This area is part of the former Peatland Development Project (PLG) and is currently being redeveloped into a food estate to support Indonesia’s national food security efforts beyond Java Island. A 2020 survey revealed that farmers in the region were reluctant to cultivate rice due to frequent flooding that often led to crop failure. A primary cause of these floods is the deterioration of water control infrastructure; at least ten water gates are non-functional, leading to uncontrolled water flow within the irrigation system. Since 2020, rehabilitation efforts have been initiated to restore the swamp irrigation network, including the repair of channels and water gates to improve flow regulation. This study evaluates the impact of these rehabilitation efforts on water management in the Dadahup DIR. Hydraulic simulations using HEC-RAS were performed to compare pre- and post-rehabilitation conditions, utilizing data on channel geometry, gate characteristics, and water levels. The findings with gate scenario maintained notably lower and more stable water levels, generally ranging from 1.41 m to 1.6 m. The average reduction of approximately 0.30–0.40 m relative to the ungated condition underscores the gate’s effectiveness in attenuating hydraulic surges and regulating downstream water levels. The scenario with gate maintained a consistently lower and more stable discharge in the range of 0-1.7 m 3 /s throughout the observation period.
- 1 March 2026
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 1593 (1)
Open AccessEffectiveness Study of Water Control Structures Rehabilitation in Dadahup Swamp Irrigation Area, Central Kalimantan
The Dadahup Swamp Irrigation Area (DIR), located in the Dadahup and Kapuas Murung Subdistricts of Kapuas Regency, Central Kalimantan, encompasses 21,226 hectares of agricultural land. This area is part of the former Peatland Development Project (PLG) and is currently being redeveloped into a food estate to support Indonesia’s national food security efforts beyond Java Island. A 2020 survey revealed that farmers in the region were reluctant to cultivate rice due to frequent flooding that often led to crop failure. A primary cause of these floods is the deterioration of water control infrastructure; at least ten water gates are non-functional, leading to uncontrolled water flow within the irrigation system. Since 2020, rehabilitation efforts have been initiated to restore the swamp irrigation network, including the repair of channels and water gates to improve flow regulation. This study evaluates the impact of these rehabilitation efforts on water management in the Dadahup DIR. Hydraulic simulations using HEC-RAS were performed to compare pre- and post-rehabilitation conditions, utilizing data on channel geometry, gate characteristics, and water levels. The findings with gate scenario maintained notably lower and more stable water levels, generally ranging from 1.41 m to 1.6 m. The average reduction of approximately 0.30–0.40 m relative to the ungated condition underscores the gate’s effectiveness in attenuating hydraulic surges and regulating downstream water levels. The scenario with gate maintained a consistently lower and more stable discharge in the range of 0-1.7 m 3 /s throughout the observation period.
- Open Access
- 1 February 2026
- Published by Ital Publication in Civil Engineering Journal
- Vol. 12 (2) , 801-821
Scour Morphology Comparison Around Oblong Bridge Pier: Clear-Water and Live-Bed Flow Conditions
Bridge pier scour is a significant contributor to structural instability in riverine infrastructure, particularly in sediment-laden tropical rivers. Streamlined shapes such as oblong piers generally produce smaller scour depths than bluff-body piers, offering potential safety advantages. However, the morphological evolution of scour under different sediment-transport regimes and its implications for structural stability remain insufficiently documented. This study experimentally compares clear-water (CW) and live-bed (LB) scour around an oblong pier, with emphasis on equilibrium depth, temporal development, three-dimensional morphology, velocity structure, and safety relevance. Flume tests were performed using a 5-cm × 10-cm oblong pier under steady subcritical flow (Q = 50 L/s, h = 10 cm, d50 = 2.21 mm, Fr < 1), with CW simulated by eliminating upstream sediment supply and LB by continuous sediment recirculation. Velocity measurements using an Acoustic Doppler Velocimeter (ADV) were conducted at equilibrium scour geometry to characterize flow structures. Results show CW scour reached a deeper equilibrium (z/D = 1.70), developed 36.4% faster (T* = 666 min) than LB (z/D = 1.52, T* = 909 min). CW formed a symmetric, steep-walled scour hole with 14.1% greater volume and 15.6% wider planform area, creating an immediate risk of vertical undermining. LB produced a shallower, more elongated scour with partial downstream backfilling, leading to gradual longitudinal undermining and slower foundation settlement. Velocity measurements revealed stronger vertical and lateral fluctuations under LB, explaining its more irregular scour morphology. Although the reduced scour depth confirms previous findings for streamlined piers, the elongated downstream scour and partial backfilling under LB provide new insights for countermeasure design. Among the tested predictors, Sheppard's Equation performed best with 8% (CW) and 3% (LB) deviations. These findings confirm that streamlined oblong piers reduce the maximum scour depth compared with circular shapes, but reveal contrasting mechanisms: CW promotes rapid, concentrated erosion, whereas LB induces slower, more widespread scour. The results emphasize that countermeasure design must explicitly account for the sediment-transport regime to ensure long-term foundation stability.
- 1 February 2026
- Published by Ital Publication in Civil Engineering Journal
- Vol. 12 (2) , 801-821
Open AccessScour Morphology Comparison Around Oblong Bridge Pier: Clear-Water and Live-Bed Flow Conditions
Bridge pier scour is a significant contributor to structural instability in riverine infrastructure, particularly in sediment-laden tropical rivers. Streamlined shapes such as oblong piers generally produce smaller scour depths than bluff-body piers, offering potential safety advantages. However, the morphological evolution of scour under different sediment-transport regimes and its implications for structural stability remain insufficiently documented. This study experimentally compares clear-water (CW) and live-bed (LB) scour around an oblong pier, with emphasis on equilibrium depth, temporal development, three-dimensional morphology, velocity structure, and safety relevance. Flume tests were performed using a 5-cm × 10-cm oblong pier under steady subcritical flow (Q = 50 L/s, h = 10 cm, d50 = 2.21 mm, Fr < 1), with CW simulated by eliminating upstream sediment supply and LB by continuous sediment recirculation. Velocity measurements using an Acoustic Doppler Velocimeter (ADV) were conducted at equilibrium scour geometry to characterize flow structures. Results show CW scour reached a deeper equilibrium (z/D = 1.70), developed 36.4% faster (T* = 666 min) than LB (z/D = 1.52, T* = 909 min). CW formed a symmetric, steep-walled scour hole with 14.1% greater volume and 15.6% wider planform area, creating an immediate risk of vertical undermining. LB produced a shallower, more elongated scour with partial downstream backfilling, leading to gradual longitudinal undermining and slower foundation settlement. Velocity measurements revealed stronger vertical and lateral fluctuations under LB, explaining its more irregular scour morphology. Although the reduced scour depth confirms previous findings for streamlined piers, the elongated downstream scour and partial backfilling under LB provide new insights for countermeasure design. Among the tested predictors, Sheppard's Equation performed best with 8% (CW) and 3% (LB) deviations. These findings confirm that streamlined oblong piers reduce the maximum scour depth compared with circular shapes, but reveal contrasting mechanisms: CW promotes rapid, concentrated erosion, whereas LB induces slower, more widespread scour. The results emphasize that countermeasure design must explicitly account for the sediment-transport regime to ensure long-term foundation stability.
- Open Access
- 1 February 2026
- Published by KEAI Publishing in International Journal of Sediment Research
- Vol. 41 (1) , 1-22
Turbulence structure and near-wall suppression in equilibrium and nonequilibrium sediment transport: An experimental study
- 1 February 2026
- Published by KEAI Publishing in International Journal of Sediment Research
- Vol. 41 (1) , 1-22
Open AccessTurbulence structure and near-wall suppression in equilibrium and nonequilibrium sediment transport: An experimental study
- Open Access
- 14 May 2025
- Published by Universitas Muhammadiyah Yogyakarta in Semesta Teknika
- Vol. 28 (1) , 47-61
Evaluating Flow Resistance in Straight Channels Using 2-Point Velocity Measurements
Accurately measuring Manning’s roughness coefficient is crucial for enhancing the precision of hydraulic models and supporting informed decision-making in water resource management. Traditionally, this coefficient is determined using the cross-sectional mean velocity, which may introduce inaccuracies due to its approximate nature. However, estimating Manning’s roughness coefficient through flow velocity distribution analysis remains a relatively underexplored approach. This study aims to improve the accuracy of estimating Manning’s roughness coefficient by analyzing the velocity distribution at two vertical positions within the flow: z/H = 0.2 and z/H = 0.8. Secondary velocity data were obtained from four locations to support this investigation: a laboratory flume, the Selokan Mataram irrigation channel, the Kuning River, and the Opak River. The research methodology involves simplifying and applying analytical equations needed to determine Manning’s roughness coefficient based on the velocity profile. The results indicate that, in natural river systems, Manning’s roughness coefficient ranges from 0.035 to 0.095 at z/H = 0.8 and z/H = 0.2 and from 0.032 to 0.085 at z/H = 0.4 and z/H = 0.2.
- 14 May 2025
- Published by Universitas Muhammadiyah Yogyakarta in Semesta Teknika
- Vol. 28 (1) , 47-61
Open AccessEvaluating Flow Resistance in Straight Channels Using 2-Point Velocity Measurements
Accurately measuring Manning’s roughness coefficient is crucial for enhancing the precision of hydraulic models and supporting informed decision-making in water resource management. Traditionally, this coefficient is determined using the cross-sectional mean velocity, which may introduce inaccuracies due to its approximate nature. However, estimating Manning’s roughness coefficient through flow velocity distribution analysis remains a relatively underexplored approach. This study aims to improve the accuracy of estimating Manning’s roughness coefficient by analyzing the velocity distribution at two vertical positions within the flow: z/H = 0.2 and z/H = 0.8. Secondary velocity data were obtained from four locations to support this investigation: a laboratory flume, the Selokan Mataram irrigation channel, the Kuning River, and the Opak River. The research methodology involves simplifying and applying analytical equations needed to determine Manning’s roughness coefficient based on the velocity profile. The results indicate that, in natural river systems, Manning’s roughness coefficient ranges from 0.035 to 0.095 at z/H = 0.8 and z/H = 0.2 and from 0.032 to 0.085 at z/H = 0.4 and z/H = 0.2.
- Open Access
- 1 April 2021
- Published by Brawijaya University in Civil and Environmental Science
- Vol. 004 (01) , 093-105
Bed-Shear Velocity Measurement in Curved Open Channel
Generally, the condition of the rivers in Indonesia are alluvial rivers which had meanders, where the change in the river bed topography often occur. One of the parameters associated with changes in the river bed topography is bed-shear velocity, or Reynolds stress. The bed-shear velocity can be calculated by the Reynolds stress distribution method and the Clauser method which commonly used in straight channels. In fact, on natural channel there is a curve and even a meandering channel. With more complex flow conditions, the use of the Clauser method in curved channels can be questioned, is it still accurate or not. In this paper, both methods will be discussed by comparing the measurement data in the laboratory using 180 curved channel with flat bed. The results of data analysis show that the use of these two methods in curved channels produces an average difference of around 19.81%, where the Clauser method gives greater results and better tendencies. Apart from the differences in the results given, it can be said that the Clauser method as well as the Reynolds stress distribution method can still be used to calculate the bed-shear velocity in the curved channel
- 1 April 2021
- Published by Brawijaya University in Civil and Environmental Science
- Vol. 004 (01) , 093-105
Open AccessBed-Shear Velocity Measurement in Curved Open Channel
Generally, the condition of the rivers in Indonesia are alluvial rivers which had meanders, where the change in the river bed topography often occur. One of the parameters associated with changes in the river bed topography is bed-shear velocity, or Reynolds stress. The bed-shear velocity can be calculated by the Reynolds stress distribution method and the Clauser method which commonly used in straight channels. In fact, on natural channel there is a curve and even a meandering channel. With more complex flow conditions, the use of the Clauser method in curved channels can be questioned, is it still accurate or not. In this paper, both methods will be discussed by comparing the measurement data in the laboratory using 180 curved channel with flat bed. The results of data analysis show that the use of these two methods in curved channels produces an average difference of around 19.81%, where the Clauser method gives greater results and better tendencies. Apart from the differences in the results given, it can be said that the Clauser method as well as the Reynolds stress distribution method can still be used to calculate the bed-shear velocity in the curved channel
- Open Access
- 1 January 2018
- Published by Universitas Muhammadiyah Yogyakarta in Semesta Teknika
- Vol. 21 (1) , 53-59
Kajian Angkutan Sedimen Di Sungai Pabelan, Kabupaten Magelang, Jawa Tengah
Kajian Angkutan Sedimen Di Sungai Pabelan, Kabupaten Magelang, Jawa Tengah
- 1 January 2018
- Published by Universitas Muhammadiyah Yogyakarta in Semesta Teknika
- Vol. 21 (1) , 53-59
Open AccessKajian Angkutan Sedimen Di Sungai Pabelan, Kabupaten Magelang, Jawa Tengah
Kajian Angkutan Sedimen Di Sungai Pabelan, Kabupaten Magelang, Jawa Tengah
- Open Access
- 1 January 2017
- Published by Elsevier in Procedia Engineering
- Vol. 170, 202-209
Numerical Simulation of Sediment Transport along a Channel with Underwater Sill
- 1 January 2017
- Published by Elsevier in Procedia Engineering
- Vol. 170, 202-209
Open AccessNumerical Simulation of Sediment Transport along a Channel with Underwater Sill
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1755 (1) , 060003
Freezing concentration in AODs toxicity test
Freezing of water solution to amplify concentration of impurities in the water is part of AODs (Aquatic Organisms Environmental Diagnostic-stream) toxicity test procedure. The quality of AODs test solution determined the bioassay results of the concentrated solution resulted from freezing. Making the test solution for AODs by freezing concentration technique needs to be reviewed and adjusted since the freezing procedure of AODs is different from the country where the AOD method was first developed. The research objective was to evaluate the freezing performance of sample solution of AODs toxicity test at a certain speed of rotary evaporator i.e. 60-70 rpm, the quality of isopropyl alcohol at a cooling temperature of −15°C to −20°C, room temperature of 25°C. Efficiency recovery of solute was calculated at 180%, 320%, 560%, 1000% and 1800% freezing concentration. Evaluation of AODs freezing techniques was conducted ex-situ in the laboratory, on water samples taken from 5 locations in the Gadjah Wong stream. The research resulted in some important information for freezing concentration standardization procedure. The higher the volume ratio of the concentration, the longer the time of freezing process at a fixed rotational speed. It took between 15 minutes to 2 hours to have a final volume of 100 ml solution from various volume ratios. There were differences in recovery efficiency of solute at various freezing concentrations and with various solute concentrations in the river water samples. The higher the solute concentration level in the river water sample, the lower the recovery efficiency of the solute. High solute concentration usually represents the river water quality in dry season. Pretty good recovery efficiency (80-100%) only achieved in a solution with a low freezing concentration (180%, 320% and 560%). Good recovery efficiency of solute was resulted in low solute concentration and low TDS or EC concentrations in the river water samples. The freezing concentration techniques performance does not contradict with previous other expert’s research and successfully represent the sample test solution for standardization of AODs method.
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1755 (1) , 060003
Freezing concentration in AODs toxicity test
Freezing of water solution to amplify concentration of impurities in the water is part of AODs (Aquatic Organisms Environmental Diagnostic-stream) toxicity test procedure. The quality of AODs test solution determined the bioassay results of the concentrated solution resulted from freezing. Making the test solution for AODs by freezing concentration technique needs to be reviewed and adjusted since the freezing procedure of AODs is different from the country where the AOD method was first developed. The research objective was to evaluate the freezing performance of sample solution of AODs toxicity test at a certain speed of rotary evaporator i.e. 60-70 rpm, the quality of isopropyl alcohol at a cooling temperature of −15°C to −20°C, room temperature of 25°C. Efficiency recovery of solute was calculated at 180%, 320%, 560%, 1000% and 1800% freezing concentration. Evaluation of AODs freezing techniques was conducted ex-situ in the laboratory, on water samples taken from 5 locations in the Gadjah Wong stream. The research resulted in some important information for freezing concentration standardization procedure. The higher the volume ratio of the concentration, the longer the time of freezing process at a fixed rotational speed. It took between 15 minutes to 2 hours to have a final volume of 100 ml solution from various volume ratios. There were differences in recovery efficiency of solute at various freezing concentrations and with various solute concentrations in the river water samples. The higher the solute concentration level in the river water sample, the lower the recovery efficiency of the solute. High solute concentration usually represents the river water quality in dry season. Pretty good recovery efficiency (80-100%) only achieved in a solution with a low freezing concentration (180%, 320% and 560%). Good recovery efficiency of solute was resulted in low solute concentration and low TDS or EC concentrations in the river water samples. The freezing concentration techniques performance does not contradict with previous other expert’s research and successfully represent the sample test solution for standardization of AODs method.