CHChotimah

Chotimah

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chotimah has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Agri-food waste utilization as activated carbon in PVA-chitosan sheets for transparent food packaging potential

    by Ari Dwi Nugraheni, Rini Murtafi’ATin, Nurmayasari, Nurul Fajariah, Affifah Dias Salsabilla, Juliasih Partini, Chotimah

  • Electronic nose-based monitoring of vacuum-packaged chicken meat freshness in room and refrigerated storage

    by Chotimah, Khalid Saifullah, Fitri Nur Laily, Mayumi Puspita, Kombo Othman Kombo, Shidiq Nur Hidayat, Eko Tri Sulistyani, Wahyono, Kuwat Triyana


  • Open Access

    Cell Viability Assay and Surface Morphology Analysis of Carbonated Hydroxyapatite/Honeycomb/Titanium Alloy Coatings for Bone Implant Applications

    by Mona Sari, Chotimah, Ika Dewi Ana, Yusril Yusuf

    In this work, carbonated hydroxyapatite/titanium alloy (CHA/Ti) and carbonated hydroxyapatite/honeycomb/titanium alloy (CHA/HCB/Ti) plates were coated using the electrophoretic deposition dip coating (EP2D) method. Analysis of cell viability and surface morphology of CHA/Ti and CHA/HCB/Ti coatings were carried out using the MTT (3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay and scanning electron microscopy (SEM), respectively. In a previous study, the thickness and average compressive strength values for the CHA/Ti and CHA/HCB/Ti plates were about 63–89 μm and 54–75 MPa, respectively. The result for thickness and compressive strength in this research followed the thickness and compressive strength parameters for coating in bone implants. In this work, the cell viability for incubation times during 24 h and 48 h of CHA/Ti plates is demonstrably superior to that of CHA/HCB/Ti plates, respectively, where the cell viability for CHA/Ti plates increased to ((67 ± 2)%) after incubation for 48 h. According to the one-way analysis of variance (ANOVA), the p-value was <0.05, indicating a significant difference in the average cell viability value across the three groups. Furthermore, the surface of CHA/Ti is not changed after the coating process. These results will yield many positive biomedical applications, especially in bone implants. Overall, CHA/Ti and CHA/HCB/Ti plates can be considered candidates for biomedical applications based on an analysis of surface morphology and cell viability.


  • Open Access

    Carbonated Hydroxyapatite-Based Honeycomb Scaffold Coatings on a Titanium Alloy for Bone Implant Application—Physicochemical and Mechanical Properties Analysis

    by Mona Sari, Nicholas Adi Kristianto, Chotimah, Ika Dewi Ana, Yusril Yusuf

    In this work, carbonated hydroxyapatite (CHA) based on abalone mussel shells (Haliotis asinina) is synthesized using the co-precipitation method. The synthesized CHA was mixed with honeycomb (HCB) 40 wt.% for the scaffold fabrication process. CHA and scaffold CHA/HCB 40 wt.% were used for coating a Titanium (Ti) alloy using the electrophoretic deposition dip coating (EP2D) method with immersion times of 10, 20, and 30 min. The synthesized B-type CHA with a stirring time of 45 min could have lower transmittance values and smaller crystallite size. Energy dispersive X-ray spectroscopy (EDS) showed that the Ca/P molar ratio was 1.79. The scaffold CHA/HCB 40 wt.% had macropore size, micropore size, and porosity of 102.02 ± 9.88 μm, 1.08 ± 0.086 μm, and 66.36%, respectively, and therefore it can also be applied in the coating process for bone implant applications due to the potential scaffold for bone growth. Thus, it has the potential for coating on Ti alloy applications. In this study, the compressive strength for all immersion time variations was about 54–83 MPa. The average compression strengths of human cancellous bone were about 0.2–80 MPa. The thickness obtained was in accordance with the thickness parameters required for a coating of 50–200 μm.


  • Open Access

    Nanostructured Titanium Dioxide for Functional Coatings

    by Indriana Kartini, Inna Yusnila Khairani, Chotimah, Kuwat Triyana, Sri Wahyuni

    Synthesis routes to nanostructured titanium dioxides (spherical nanoparticles, nanotubes, mesostructure) have been studied. Their potential applications in various fields based on coating technology have been explored, i.e., dye-sensitized solar cells (using ruthenium sensitizer and some results of natural dyes), photocatalysts for self-cleaning films (TiO2 on textiles), antibacterial coating for multifunctional textiles (TiO2-SiO2 on cotton), and recent result on antifouling coating on wood. The synthesis/preparation procedures were developed to obtain green protocols based on combined techniques of hydro- or solvo-thermal (templated, seeded, deposition), sol–gel (templated, room temperature, dip coating), and solvent-casting techniques. Discussion on the properties and synthesis mechanism is presented. It will be shown that sonication has important role to shorten the preparation of nanotube titania and has been proposed as one green synthesis route. The changing of morphology of titanium dioxide has presented unexpected results to the shifting of photoactivity into visible irradiation.


  • The electrical properties of PEDOT:PSS nanofibers

    by Chotimah, Bimo Winandianto, Misbachul Munir, Indriana Kartini, Ahmad Kusumaatmaja, Kuwat Triyana

    Fabrication of nanofibers based on conducting polymer of poly(3,4-ethylenedioxythiophene) (PEDOT) doped with poly(p-phenylene sulfide) or PEDOT:PSS has been carried out using electrospinning technique. In this study, poly (vinyl alcohol) (PVA) as a matrix was added. I addition, the dimethyl sulfoxide (DMSO) was also added to PEDOT:PSS/PVA nanofibers to improve the conductivity. The measurement of resistance a thin layer of done with the two-point probe method. A thin layer of PEDOT:PSS and blend PEDOT:PSS/PVA in preparation above the substrate by a method of spin coatings and electrospinning. The morphology and diameter of PEDOT:PSS:PVA nanofibers were determined with a scanning electron microscope or SEM (JEOL, JSM-6510LA), while the chemical compositions of nanofibers were determined using Fourier transform infrared (FTIR). The observation was made with variations of probe position of grids. The measurement result suggests contact between a probe and the PEDOT:PSS is ohmic contact, and the addition of DMSO decreases significantly the resistance of PEDOT:PSS:PVA nanofibers.